1.  Development of electrocardiogram intervals during growth of FVB/N neonate mice 
BMC Physiology  2010;10:16.
Background
Electrocardiography remains the best diagnostic tool and therapeutic biomarker for a spectrum of pediatric diseases involving cardiac or autonomic nervous system defects. As genetic links to these disorders are established and transgenic mouse models produced in efforts to understand and treat them, there is a surprising lack of information on electrocardiograms (ECGs) and ECG abnormalities in neonate mice. This is likely due to the trauma and anaesthesia required of many legacy approaches to ECG recording in mice, exacerbated by the fragility of many mutant neonates. Here, we use a non-invasive system to characterize development of the heart rate and electrocardiogram throughout the growth of conscious neonate FVB/N mice.
Results
We examine ECG waveforms as early as two days after birth. At this point males and females demonstrate comparable heart rates that are 50% lower than adult mice. Neonatal mice exhibit very low heart rate variability. Within 12 days of birth PR, QRS and QTc interval durations are near adult values while heart rate continues to increase until weaning. Upon weaning FVB/N females quickly develop slower heart rates than males, though PR intervals are comparable between sexes until a later age. This suggests separate developmental events may contribute to these gender differences in electrocardiography.
Conclusions
We provide insight with a new level of detail to the natural course of heart rate establishment in neonate mice. ECG can now be conveniently and repeatedly used in neonatal mice. This should serve to be of broad utility, facilitating further investigations into development of a diverse group of diseases and therapeutics in preclinical mouse studies.
doi:10.1186/1472-6793-10-16
PMCID: PMC2936334  PMID: 20735846
2.  Method for non-invasively recording electrocardiograms in conscious mice 
BMC Physiology  2001;1:6.
Background
The rapid increase in the development of mouse models is resulting in a growing demand for non-invasive physiological monitoring of large quantities of mice. Accordingly, we developed a new system for recording electrocardiograms (ECGs) in conscious mice without anesthesia or implants, and created Internet-accessible software for analyzing murine ECG signals. The system includes paw-sized conductive electrodes embedded in a platform configured to record ECGs when 3 single electrodes contact 3 paws.
Results
With this technique we demonstrated significantly reduced heart rate variability in neonates compared to adult mice. We also demonstrated that female mice exhibit significant ECG differences in comparison to age-matched males, both at baseline and in response to ╬▓-adrenergic stimulation.
Conclusions
The technology we developed enables non-invasive screening of large numbers of mice for ECG changes resulting from genetic, pharmacological, or pathophysiological alterations. Data we obtained non-invasively are not only consistent with what have been reported using invasive and expensive methods, but also demonstrate new findings regarding gender-dependent and age-dependent variations in ECGs in mice.