1.  Continuous insulin administration via complex central venous catheter infusion tubing is another risk factor for blood glucose imbalance. A retrospective study 
Background
We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device.
Methods
We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin].
Results
Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71–48.8; p < 0.001).
Conclusions
The administration of on-demand medication through tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.
doi:10.1186/2110-5820-2-16
PMCID: PMC3409028  PMID: 22697362
Hypoglycemia; Intensive care unit; Infusion tubing; Central venous catheter; Intensive insulin therapy
2.  Comparison of superior vena cava and femoroiliac vein pressure according to intra-abdominal pressure 
Background
Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown.
Methods
We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure.
Results
A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52–76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2–5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002).
Conclusions
We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.
doi:10.1186/2110-5820-2-21
PMCID: PMC3424143  PMID: 22742667
Intensive unit care; Central venous pressure; Superior vena cava; Femoroiliac vena; Intra-abdominal pressure