1.  Combined SPECT and multidetector CT for prostate cancer evaluations 
111In-capromab pendetide is an imaging probe for noninvasive detection of prostate cancer dissemination, and can be difficult to interpret because of low photon statistics resulting in noisy images with limited anatomical precision. We examined if a 16-slice multidetector computed tomography (MDCT) combined with single photon emission computed tomography (SPECT) could increase the impact on the clinical management and improve confidence in SPECT image interpretations in comparison to a relatively low-mA (limited resolution) CT. 17 scans were reviewed from a SPECT combined with low-mA CT scanner; 21 scans were reviewed from a SPECT combined with 16-slice MDCT scanner. Reports of the clinical interpretations from the imaging studies, additional examinations performed by referring physicians as a follow-up to the imaging results, and long-term clinical and laboratory follow-ups were used to define confidence of the SPECT/CT readings and impact of the readings on the patient management. The impact was defined as: the occurrence of the 111In-capromab pendetide interpretation resulted in additional imaging studies or biopsies. MDCT improved the quality and confidence in the characterization of small lymph nodes with or without uptake of 111In-capromab pendetide. The increased confidence with MDCT in SPECT/CT readings was evident in all cases reviewed in this study, and the impact on the clinical management was higher (8 out of 21) using SPECT/MDCT than the impact using SPECT combined with low-mA CT (2 out of 17). The dual-modality SPECT/CT provides a quantifiable benefit when MDCT is used instead of low-mA CT, particularly for prostate cancer evaluations using 111In-capromab pendetide.
PMCID: PMC3260786  PMID: 22267999
Prostate cancer; capromab pendetide; SPECT/CT; MDCT; prostate specific membrane antigen (PSMA)
2.  Myocardial blood flow measurement with a conventional dual-head SPECT/CT with spatiotemporal iterative reconstructions - a clinical feasibility study 
Cardiac single photon emission computed tomography (SPECT) cameras typically rotate too slowly around a patient to capture changes in the blood pool activity distribution and provide accurate kinetic parameters. A spatiotemporal iterative reconstruction method to overcome these limitations was investigated. Dynamic rest/stress 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SPECT/CT was performed along with reference standard rest/stress dynamic positron emission tomography (PET/CT) 13N-NH3 in five patients. The SPECT data were reconstructed using conventional and spatiotemporal iterative reconstruction methods. The spatiotemporal reconstruction yielded improved image quality, defined here as a statistically significant (p<0.01) 50% contrast enhancement. We did not observe a statistically significant difference between the correlations of the conventional and spatiotemporal SPECT myocardial uptake K 1 values with PET K 1 values (r=0.25, 0.88, respectively) (p<0.17). These results indicate the clinical feasibility of quantitative, dynamic SPECT/CT using 99mTc-MIBI and warrant further investigation. Spatiotemporal reconstruction clearly provides an advantage over a conventional reconstruction in computing K 1.
PMCID: PMC3867729  PMID: 24380045
Dynamic SPECT; myocardial perfusion imaging; 99mTc-MIBI; SPECT/CT; spatiotemporal reconstruction; uptake rate constant
3.  Combined SPECT and Multidetector CT for Prostate Cancer Evaluations 
111In-capromab pendetide is an imaging probe for noninvasive detection of prostate cancer dissemination, and can be difficult to interpret because of low photon statistics resulting in noisy images with limited anatomical precision. We examined if a 16-slice multidetector computed tomography (MDCT) combined with single photon emission computed tomography (SPECT) could increase the impact on the clinical management and improve confidence in SPECT image interpretations in comparison to a relatively low-mA (limited resolution) CT. 17 scans were reviewed from a SPECT combined with low-mA CT scanner; 21 scans were reviewed from a SPECT combined with 16-slice MDCT scanner. Reports of the clinical interpretations from the imaging studies, additional examinations performed by referring physicians as a follow-up to the imaging results, and long-term clinical and laboratory follow-ups were used to define confidence of the SPECT/CT readings and impact of the readings on the patient management. The impact was defined as: the occurrence of the 111In-capromab pendetide interpretation resulted in additional imaging studies or biopsies. MDCT improved the quality and confidence in the characterization of small lymph nodes with or without uptake of 111In-capromab pendetide. The increased confidence with MDCT in SPECT/CT readings was evident in all cases reviewed in this study, and the impact on the clinical management was higher (8 out of 21) using SPECT/MDCT than the impact using SPECT combined with low-mA CT (2 out of 17). The dual-modality SPECT/CT provides a quantifiable benefit when MDCT is used instead of low-mA CT, particularly for prostate cancer evaluations using 111In-capromab pendetide.
PMCID: PMC3260786  PMID: 22267999
prostate cancer; capromab pendetide; SPECT/CT; MDCT; prostate specific membrane antigen (PSMA)