1.  Interobserver reproducibility of electroencephalogram interpretation in critically ill children 
Purpose
Correct outcome prediction after cardiac arrest in children may improve clinical decision making and family counseling. Various investigators have used EEG to predict outcome with varying success, but one limiting issue is the potential lack of reproducibility of EEG interpretation. Therefore, we aimed to evaluate interobserver agreement using standardized terminology in the interpretation of EEG tracings obtained from critically ill children following cardiac arrest.
Methods
3 pediatric neurophysiologists scored 74 EEG samples using standardized categories, terminology, and interpretation rules. Interobserver agreement was evaluated using kappa and intra-class correlation coefficients.
Results
Agreement was substantial for the categories of continuity, burst suppression, sleep architecture, and overall rating. Agreement was moderate for seizure occurrence and inter-ictal epileptiform discharge type. Agreement was fair for inter-ictal epileptiform discharge presence, beta activity, predominant frequency, and fastest frequency. Agreement was slight for maximum voltage and focal slowing presence.
Conclusions
The variability of inter-rater agreement suggests that some EEG features are superior to others for use in a predictive algorithm. Using only reproducible EEG features is needed to ensure the most accurate and consistent predictions. Since even seizure identification had only moderate agreement, studies of non-convulsive seizures in critically ill patients must be conducted and interpreted cautiously.
doi:10.1097/WNP.0b013e3182051123
PMCID: PMC3107383  PMID: 21221016
Electroencephalogram; Interobserver variability; Seizure; Pediatric; Hypoxic Ischemic Encephalopathy; Cardiac Arrest