1.  Substantial and reversible brain gray matter reduction but no acute brain lesions in ultramarathon runners: experience from the TransEurope-FootRace Project 
BMC Medicine  2012;10:170.
During the extremely challenging 4,487 km ultramarathon TransEurope-FootRace 2009, runners showed considerable reduction of body weight. The effects of this endurance run on brain volume changes but also possible formation of brain edema or new lesions were explored by repeated magnetic resonance imaging (MRI) studies.
A total of 15 runners signed an informed consent to participate in this study of planned brain scans before, twice during, and about 8 months after the race. Because of dropouts, global gray matter volume analysis could only be performed in ten runners covering three timepoints, and in seven runners who also had a follow-up scan. Scanning was performed on three identical 1.5 T Siemens MAGNETOM Avanto scanners, two of them located at our university. The third MRI scanner with identical sequence parameters was a mobile MRI unit escorting the runners. Volumetric 3D datasets were acquired using a magnetization prepared rapid acquisition gradient echo (MPRAGE) sequence. Additionally, diffusion-weighted (DWI) and fluid attenuated inversion recovery (FLAIR) imaging was performed.
Average global gray matter volume as well as body weight significantly decreased by 6% during the race. After 8 months, gray matter volume returned to baseline as well as body weight. No new brain lesions were detected by DWI or FLAIR imaging.
Physiological brain volume reduction during aging is less than 0.2% per year. Therefore a volume reduction of about 6% during the 2 months of extreme running appears to be substantial. The reconstitution in global volume measures after 8 months shows the process to be reversible. As possible mechanisms we discuss loss of protein, hypercortisolism and hyponatremia to account for both substantiality and reversibility of gray matter volume reductions. Reversible brain volume reduction during an ultramarathon suggests that extreme running might serve as a model to investigate possible mechanisms of transient brain volume changes. However, despite massive metabolic load, we found no new lesions in trained athletes participating in a multistage ultramarathon.
See related commentary
PMCID: PMC3566943  PMID: 23259507
body weight; brain volume; catabolism; DWI; lesion; MRI; ultramarathon
2.  Sixty-four MDCT achieves higher contrast in pancreas with optimization of scan time delay 
World Journal of Radiology  2012;4(7):324-327.
AIM: To compare different multidetector computed tomography (MDCT) protocols to optimize pancreatic contrast enhancement.
METHODS: Forty consecutive patients underwent contrast-enhanced biphasic MDCT (arterial and portal-venous phase) using a 64-slice MDCT. In 20 patients, the scan protocol was adapted from a previously used 40-channel MDCT scanner with arterial phase scanning initiated 11.1 s after a threshold of 150 HU was reached in the descending aorta, using automatic bolus tracking (Protocol 1). The 11.1-s delay was changed to 15 s in the other 20 patients to reflect the shorter scanning times on the 64-channel MDCT compared to the previous 40-channel system (Protocol 2). HU values were measured in the head and tail of the pancreas in the arterial and portal-venous phase.
RESULTS: Using an 11.1-s delay, 74.2 HU (head) were measured on average in the arterial phase and 111.2 HU (head) were measured using a 15-s delay (P < 0.0001). For the pancreatic tail, the average attenuation level was 76.73 HU (11.1 s) and 99.89 HU (15 s) respectively (P = 0.0002). HU values were also significantly higher in the portal-venous phase [pancreatic head: 70.5 HU (11.1 s) vs 84.0 HU (15 s) (P = 0.0014); pancreatic tail: 67.45 HU (11.1 s) and 77.18 HU (15 s) using Protocol 2 (P = 0.0071)].
CONCLUSION: Sixty-four MDCT may yield a higher contrast in pancreatic study with (appropriate) optimization of scan delay time.
PMCID: PMC3419869  PMID: 22900134
Computed tomography; Pancreas; Scan delay; Protocol; Contrast enhancement