PMCC PMCC

Search tips
Search criteria

Advanced
Results 1-2 (2)
 

Clipboard (0)
None

Select a Filter Below

Journals
Authors
Year of Publication
Document Types
1.  Bronchial reactivity in green coffee exposure. 
Respiratory symptoms and lung function were studied in nine coffee workers who complained of job related respiratory symptoms. Six described symptoms characteristic of occupational asthma. Lung function data showed obstructive changes mostly in the smaller airways with no impairment in diffusing capacity. Bronchoprovocation testing with green coffee allergen provoked immediate asthmatic reactions with acute reductions of ventilatory capacity in four workers. The relative fall in FEF25-75% (ranging from 28% to 66%) was greater than in FEV1 (ranging from 18% to 62% of the control values). Eight of the nine workers had an increased total IgE serum level; five had positive intradermal skin tests to green coffee allergen. Most of the six healthy subjects experimentally exposed to green coffee dust in the working environment showed an acute fall in flow rates on maximum expiratory flow-volume curves. These results indicate that bronchoprovocation with green coffee allergen or green coffee dust may be used to identify subjects sensitive to green coffee.
PMCID: PMC1007501  PMID: 4005196
2.  Lung function in textile workers. 
Acute changes in ventilatory function during a workshift with exposure to hemp, flax, and cotton dust were measured on Mondays in a group of 61 textile workers, all working on carding machines. In addition, single-breath diffusing capacity (DLCOSB) was measured before dust exposure on Monday in 30 of the 61 workers. Large acute reductions during dust exposure were recorded in maximum expiratory flow rate at 50% VC (MEF50%), ranging from 38 to 22%. Acute reductions of FEV1-0 were considerably smaller, ranging from 17 to 9%. There was a statistically significant increase in residual volume (RV) with very small and insignificant changes in total lung capacity (TLC). Although preshift FEV1-0 and FVC were decreased, DLCOSB was within normal limits. Plethysmographic measurements in six healthy volunteers exposed to hemp-dust extract confirmed the results obtained in textile workers, that is, that TLC does not change significantly during dust-induced airway constriction and that maximum expiratory flow rate at 50% VC (MEF50%) is a more sensitive test than FEV1-0 in detecting acute ventilatory changes caused by the dust extract.
PMCID: PMC1008077  PMID: 1103956

Results 1-2 (2)