PMCC PMCC

Search tips
Search criteria

Advanced
Results 1-3 (3)
 

Clipboard (0)
None

Select a Filter Below

Journals
Authors
more »
Year of Publication
Document Types
1.  Atypical Intracranial Epidermoid Cysts: Rare Anomalies with Unique Radiological Features 
Case Reports in Radiology  2015;2015:528632.
Epidermoid cysts are benign slow growing extra-axial tumours that insinuate between brain structures, while their occurrences in intra-axial or intradiploic locations are exceptionally rare. We present the clinical, imaging, and pathological findings in two patients with atypical epidermoid cysts. CT and MRI findings for the first case revealed an intraparenchymal epidermoid cyst that demonstrated no restricted diffusion. The second case demonstrated an aggressive epidermoid cyst that invaded into the intradiploic spaces, transverse sinus, and the calvarium. The timing of ectodermal tissue sequestration during fetal development may account for the occurrence of atypical epidermoid cysts.
doi:10.1155/2015/528632
PMCID: PMC4312626  PMID: 25667778
2.  Spinal Nerve Root Haemangioblastoma Associated with Reactive Polycythemia 
Case Reports in Radiology  2014;2014:798620.
Haemangioblastomas are uncommon tumours that usually occur in the cerebellum and, less commonly, in the intramedullary spinal cord. The extramedullary spinal canal is an uncommon location for these tumours. Also haemangioblastoma at this site is not known to be associated with polycythemia. We present the clinical, imaging, and histological findings of an adult patient with extramedullary spinal haemangioblastoma and reactive polycythemia. Radiography and computed tomography (CT) revealed a medium-sized tumour that most likely arose from an extramedullary spinal nerve root. This tumour appeared to be slow growing as evidenced by the accompanying well-defined bony resorption with a sclerotic rim and mild neural foraminal widening. Magnetic resonance imaging revealed prominent flow voids consistent with tumoural hypervascularity. CT-guided biopsy was performed. Although preoperative angiographic embolisation was technically successful, excessive intraoperative tumour bleeding necessitated tumour debulking rather than complete tumour resection. Histology of the resected specimen revealed haemangioblastoma. Seven months postoperatively, the patients back pain and polycythemia have resolved.
doi:10.1155/2014/798620
PMCID: PMC4241257  PMID: 25431722
3.  Monitoring non-invasive cardiac output and stroke volume during experimental human hypovolaemia and resuscitation 
Background
Multiple methods for non-invasive measurement of cardiac output (CO) and stroke volume (SV) exist. Their comparative capabilities are not clearly established.
Methods
Healthy human subjects (n=21) underwent central hypovolaemia through progressive lower body negative pressure (LBNP) until the onset of presyncope, followed by termination of LBNP, to simulate complete resuscitation. Measurement methods were electrical bioimpedance (EBI) of the thorax and three measurements of CO and SV derived from the arterial blood pressure (ABP) waveform: the Modelflow (MF) method, the long-time interval (LTI) method, and pulse pressure (PP). We computed areas under receiver-operating characteristic curves (ROC AUCs) for the investigational metrics, to determine how well they discriminated between every combination of LBNP levels.
Results
LTI and EBI yielded similar reductions in SV during progressive hypovolaemia and resuscitation (correlation coefficient 0.83) with ROC AUCs for distinguishing major LBNP (−60 mm Hg) vs resuscitation (0 mm Hg) of 0.98 and 0.99, respectively. MF yielded very similar reductions and ROC AUCs during progressive hypovolaemia, but after resuscitation, MF-CO did not return to baseline, yielding lower ROC AUCs (ΔROC AUC range, −0.18 to −0.26, P<0.01). PP declined during hypovolaemia but tended to be an inferior indicator of specific LBNP levels, and PP did not recover during resuscitation, yielding lower ROC curves (P<0.01).
Conclusions
LTI, EBI, and MF were able to track progressive hypovolaemia. PP decreased during hypovolaemia but its magnitude of reduction underestimated reductions in SV. PP and MF were inferior for the identification of resuscitation.
doi:10.1093/bja/aeq295
PMCID: PMC3000628  PMID: 21051492
arterial pressure, measurement; blood, loss; cardiovascular system, responses; equipment, finapres; monitoring, cardiopulmonary