1.  Intraocular lens iris fixation. Clinical and macular OCT outcomes 
BMC Research Notes  2012;5:560.
Background
To assess the efficacy, clinical outcomes, visual acuity (VA), incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany) were analyzed.
Findings
The final CDVA was 20/40 or better in 8 eyes (62%), 20/60 or better in 12 eyes (92%), and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT.
Conclusions
We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method.
doi:10.1186/1756-0500-5-560
PMCID: PMC3488308  PMID: 23050659
2.  Surgical Management and Scheimpflug Analysis of an Atypical Lens Coloboma 
Case Reports in Ophthalmology  2012;3(3):317-320.
A lens coloboma is not a true coloboma; it is just a zonular absence that causes a defect in the lens equator and hence a more spherical lens. It can be isolated or in association with iris, choroid or retinal colobomas. Typically the defect is present at the site of the embryonic fissure, but it can be present elsewhere. This congenital defect can cause amblyopia, especially when it is associated with cataract. We describe a case of a 39-year-old male with an atypical coloboma that was managed successfully with phacoemulsification, capsular tension ring and intraocular lens implantation. Scheimpflug image analysis and full ophthalmological assessment were performed. Scheimpflug images demonstrated a notching of the lens equator and an absence of zonulae. During the surgical procedure an ophthalmic viscosurgical device was used to tamponade the vitreous, and after continuous curvilinear capsulorhexis the capsular tension ring was inserted to allow the surgeon to perform a safe phacoemulsification.
doi:10.1159/000343462
PMCID: PMC3493002  PMID: 23139675
Lens coloboma; Capsular tension ring; Scheimpflug image