Document Types
1.  Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use 
Critical Care  2012;16(5):R188.
Introduction
To investigate whether respiratory variation of inferior vena cava diameter (cIVC) predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure (ACF).
Methods
Forty patients with ACF and spontaneous breathing were included. Response to fluid challenge was defined as a 15% increase of subaortic velocity time index (VTI) measured by transthoracic echocardiography. Inferior vena cava diameters were recorded by a subcostal view using M Mode. The cIVC was calculated as follows: (Dmax - Dmin/Dmax) × 100 and then receiver operating characteristic (ROC) curves were generated for cIVC, baseline VTI, E wave velocity, E/A and E/Ea ratios.
Results
Among 40 included patients, 20 (50%) were responders (R). The causes of ACF were sepsis (n = 24), haemorrhage (n = 11), and dehydration (n = 5). The area under the ROC curve for cIVC was 0.77 (95% CI: 0.60-0.88). The best cutoff value was 40% (Se = 70%, Sp = 80%). The AUC of the ROC curves for baseline E wave velocity, VTI, E/A ratio, E/Ea ratio were 0.83 (95% CI: 0.68-0.93), 0.78 (95% CI: 0.61-0.88), 0.76 (95% CI: 0.59-0.89), 0.58 (95% CI: 0.41-0.75), respectively. The differences between AUC the ROC curves for cIVC and baseline E wave velocity, baseline VTI, baseline E/A ratio, and baseline E/Ea ratio were not statistically different (p = 0.46, p = 0.99, p = 1.00, p = 0.26, respectively).
Conclusion
In spontaneously breathing patients with ACF, high cIVC values (>40%) are usually associated with fluid responsiveness while low values (< 40%) do not exclude fluid responsiveness.
doi:10.1186/cc11672
PMCID: PMC3682290  PMID: 23043910
2.  Adjunctive remifentanil infusion in deeply sedated and paralyzed ICU patients during fiberoptic bronchoscopy procedure: a prospective, randomized, controlled study 
Background
Even with an adequate pain assessment, critically ill patients under sedation experience pain during procedures in the intensive care unit (ICU). We evaluated the effects of adjunctive administration of Remifentanil, a short-acting drug, in deeply sedated patient on variation of Bispectral Index (BIS) during a fiberoptic bronchoscopy.
Methods
A prospective, randomized, blinded, placebo-controlled study was conducted in 18-bed ICU. Patients needing a tracheal fibroscopy under deep sedation (midazolam (0.1 mg/kg per hour) fentanyl (4 μg/kg per hour)) and neuromuscular blocking (atracurium 0.5 mg/kg) were included in the study. A continuous monitoring of BIS, arterial pressure, and heart rate were realized before, during, and after the fiberoptic exam. An adjunctive continuous placebo or Remifentanil infusion was started just before the fiberoptic exam with a target effect-site concentration of 4 ng/ml using a Base Primea pump.
Results
Mean arterial pressure and heart rates were comparable between the placebo and Remifentanil groups at all times of the procedure. We did not observe differences in the variation of BIS values between the two groups during procedure. We described no change in BIS values relative to the placebo group in this population.
Conclusions
In deeply sedated and paralyzed patients, receiving analgesic support based on a scale score an additional administration of short-acting analgesic drug, such as Remifentanil, seems not to be necessary for acute pain control.
Trial registration
NCT00162591.
doi:10.1186/2110-5820-2-29
PMCID: PMC3487977  PMID: 22800647
Pain; Intensive care; Bispectral index; Remifentanil