PMCC PMCC

Search tips
Search criteria

Advanced
Results 1-3 (3)
 

Clipboard (0)
None

Select a Filter Below

Journals
Authors
more »
Year of Publication
Document Types
1.  Electrothermal Fluid Manipulation of High-Conductivity Samples for Laboratory Automation Applications 
JALA (Charlottesville, Va.)  2010;15(6):426-432.
Electrothermal flow is a promising technique in microfluidic manipulation toward laboratory automation applications, such as clinical diagnostics and high throughput drug screening. Despite the potential of electrothermal flow in biomedical applications, relative little is known about electrothermal manipulation of highly conductive samples, such as physiological fluids and buffer solutions. In this study, the characteristics and challenges of electrothermal manipulation of fluid samples with different conductivities were investigated systematically. Electrothermal flow was shown to create fluid motion for samples with a wide range of conductivity when the driving frequency was above 100 kHz. For samples with low conductivities (below 1 S/m), the characteristics of the electrothermal fluid motions were in quantitative agreement with the theory. For samples with high conductivities (above 1 S/m), the fluid motion appeared to deviate from the model as a result of potential electrochemical reactions and other electrothermal effects. These effects should be taken into consideration for electrothermal manipulation of biological samples with high conductivities. This study will provide insights in designing microfluidic devices for electrokinetic manipulation of biological samples toward laboratory automation applications in the future.
doi:10.1016/j.jala.2010.05.004
PMCID: PMC3003926  PMID: 21180401
2.  Electrochemical Immunosensor Detection of Urinary Lactoferrin in Clinical Samples for Urinary Tract Infection Diagnosis 
Biosensors & bioelectronics  2010;26(2):649-654.
Urine is the most abundant and easily accessible of all body fluids and provides an ideal route for non-invasive diagnosis of human diseases, particularly of the urinary tract. Electrochemical biosensors are well suited for urinary diagnostics due to their excellent sensitivity, low cost, and ability to detect a wide variety of target molecules including nucleic acids and protein biomarkers. We report the development of an electrochemical immunosensor for direct detection of the urinary tract infection (UTI) biomarker lactoferrin from infected clinical samples. An electrochemical biosensor array with alkanethiolate self-assembled monolayer (SAM) was used. Electrochemical impedance spectroscopy was used to characterize the mixed SAM, consisted of 11-mercaptoundecanoic acid and 6-mercapto-1-hexanol. A sandwich amperometric immunoassay was developed for detection of lactoferrin from urine, with a detection limit of 145 pg/ml. We validated lactoferrin as a biomarker of pyuria (presence of white blood cells in urine), an important hallmark of UTI, in 111 patient-derived urine samples. Finally, we demonstrated multiplex detection of urinary pathogens and lactoferrin through simultaneous detection of bacterial nucleic acid (16S rRNA) and host immune-response protein (lactoferrin) on a single sensor array. Our results represent first integrated sensor platform capable of quantitative pathogen identification and measurement of host immune response, potentially providing clinical diagnosis that is not only more expeditious but more informative than the current standard.
doi:10.1016/j.bios.2010.07.002
PMCID: PMC2946447  PMID: 20667707
Electrochemical biosensor; Amperometry; Urinary diagnostics; Urinary tract infections; Biomarkers
3.  Rapid Antimicrobial Susceptibility Testing Using High Surface-to-Volume Ratio Microchannels 
Analytical chemistry  2010;82(3):1012.
This study reports the use of microfluidics, which intrinsically has a large surface-to-volume ratio, toward rapid antimicrobial susceptibility testing at the point of care. By observing the growth of uropathogenic E. coli in gas permeable polymeric microchannels with different dimensions, we demonstrate that the large surface-to-volume ratio of microfluidic systems facilitates rapid growth of bacteria. For microchannels with 250 micrometer or less in depth, the effective oxygenation can sustain the growth of E. coli to over 109 cfu/ml without external agitation or oxygenation, which eliminates the requirement of bulky instrumentation and facilitates rapid bacterial growth for antimicrobial susceptibility testing at the point of care. The applicability of microfluidic rapid antimicrobial susceptibility testing is demonstrated in culture media and in urine with clinical bacterial isolates that have different antimicrobial resistance profiles. The antimicrobial resistance pattern can be determined as rapidly as 2 hours compared to days in standard clinical procedures facilitating diagnostics at the point of care.
doi:10.1021/ac9022764
PMCID: PMC2821038  PMID: 20055494

Results 1-3 (3)