1.  Platelet Recruitment during Multiple Donor Platelet Apheresis Differs between Cell Separators 
Summary
Background
Recruitment of platelets (PLT) during donor PLT apheresis may facilitate the harvest of multiple units within a single donation.
Methods
We compared two PLT apheresis procedures (Amicus and Trima Accel) in a prospective, randomized, paired cross-over study in 60 donors. The 120 donations were compared for depletion of circulating PLT in the donors, PLT yields and PLT recruitment. A recruitment was defined as ratio of total PLT yield and donor PLT depletion > 1.
Results
Despite comparable differences of pre- and post-apheresis PLT counts (87 × 109/l in Trima Accel vs. 92 × 109/l in Amicus, p = 0.383), PLT yields were higher with Trima Accel (7.48 × 1011 vs. 6.06 × 1011, p < 0.001), corresponding to a higher PLT recruitment (1.90 vs. 1.42, p < 0.001). We observed a different increase of WBC counts after aphereses, which was more pronounced with Trima Accel than with Amicus (1.30 × 109/l vs. 0.46 × 109/l, p < 0.001).
Conclusion
Both procedures induced PLT recruitment. This was higher in Trima Accel, contributing to a higher yield in spite of a comparable depletion of circulating PLT in the donors. This recruitment facilitates the harvest of multiple units within a single donation and seems to be influenced by the procedure utilized. The different increases of circulating donor white blood cells after donation need further investigation.
doi:10.1159/000328634
PMCID: PMC3128152  PMID: 21760764
Platelet apheresis; Platelet recruitment; Cell separator
2.  500 ml of blood loss does not decrease non-invasive tissue oxygen saturation (StO2) as measured by near infrared spectroscopy - A hypothesis generating pilot study in healthy adult women 
Background
The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event.
Methods
We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects.
Results
Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase.
Conclusion
StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.
doi:10.1186/1752-2897-4-5
PMCID: PMC2883964  PMID: 20465822
3.  Prospective, Paired Crossover Comparison of the in vitro Quality of Red Blood Cells Collected by the Automate for Blood Collection Device or by a Conventional Method 
Summary
Background
The prevention of the citrate shock should improve the quality of red blood cells (RBCs). We compared a conventional whole blood donation method (CONV) with a ‘Automate for Blood Collection’ (ABC), enabling a metered addition of anticoagulant and hence a correct and constant RBC-to-anticoagulant ratio throughout donation. We evaluated the performance of the ABC device and the storage quality of RBC units.
Material and Methods
The study was designed as prospective, paired crossover study with two groups of 20 donors donating first with the ABC or CONV and switching to the alternative method after 12 weeks. We measured the processing data of donations and the storage quality of RBCs on days 1, 28, and 42.
Results
ABC whole blood donations showed a slightly higher volume before and after filtration. ABC-derived RBC units revealed higher values for haematocrit, mean cellular volume, potassium and lower values for mean corpuscular haemoglobin concentration and sodium until day 42. They further showed faster glucose consumption and lactate production until day 28.
Conclusion
The ABC device is suitable for whole blood collection. The quality of the obtained RBCs is comparable to that of CONV. Avoiding the citrate shock by the described method did not improve the investigated RBC storage quality parameters.
doi:10.1159/000226092
PMCID: PMC2941835  PMID: 20877668
Whole blood donation; Citrate shock; Red blood cell storage quality