1.  Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing 
Purpose
To identify factors that determine patients’ intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral anticoagulation therapy with vitamin K antagonists, eg, warfarin.
Methods
A cross-sectional study that applied the technology-acceptance model through a self-completed questionnaire, which was administered to a convenience sample of 125 outpatients attending outpatient anticoagulation services at a district general hospital in London, UK. Data were analyzed using descriptive statistics, factor analyses, and structural equation modeling.
Results
The participants were mainly male (64%) and aged ≥ 71 years (60%). All these patients were attending the hospital outpatient anticoagulation clinic for INR testing; only two patients were currently using INR self-testing, 84% of patients had no knowledge about INR self-testing using a portable coagulometer device, and 96% of patients were never offered the option of the INR self-testing. A significant structural equation model explaining 79% of the variance in patients’ intentions to use INR self-testing was observed. The significant predictors that directly affected patients’ intention to use INR self-testing were the perception of technology (β = 0.92, P < 0.001), trust in doctor (β = −0.24, P = 0.028), and affordability (β = 0.15, P = 0.016). In addition, the perception of technology was significantly affected by trust in doctor (β = 0.43, P = 0.002), age (β = −0.32, P < 0.001), and affordability (β = 0.23, P = 0.013); thereby, the intention to use INR self-testing was indirectly affected by trust in doctor (β = 0.40), age (β = −0.29), and affordability (β = 0.21) via the perception of technology.
Conclusion
Patients’ intentions to use portable coagulometers for INR self-testing are affected by patients’ perceptions about the INR testing device, the cost of device, trust in doctors/clinicians, and the age of the patient, which need to be considered prior to any intervention involving INR self-testing by patients. Manufacturers should focus on increasing the affordability of INR testing devices for patients’ self-testing and on the potential role of medical practitioners in supporting use of these medical devices as patients move from hospital to home testing.
doi:10.2147/PPA.S38328
PMCID: PMC3536357  PMID: 23300344
oral anticoagulation; INR self-testing; technology-acceptance model; trust in doctor; home testing; affordability; structural equation modeling
2.  Patients' perspectives on self-testing of oral anticoagulation therapy: Content analysis of patients' internet blogs 
Background
Patients on oral anticoagulant therapy (OAT) require regular testing of the prothrombin time (PT) and the international normalised ratio (INR) to monitor their blood coagulation level to avoid complications of either over or under coagulation. PT/INR can be tested by a healthcare professional or by the patient. The latter mode of the testing is known as patient self-testing or home testing. The objective of this study was to elicit patients' perspectives and experiences regarding PT/INR self-testing using portable coagulometer devices.
Methods
Internet blog text mining was used to collect 246 blog postings by 108 patients, mainly from the USA and the UK. The content of these qualitative data were analysed using XSight and NVivo software packages.
Results
The key themes in relation to self-testing of OAT identified were as follows: Patient benefits reported were time saved, personal control, choice, travel reduction, cheaper testing, and peace of mind. Equipment issues included high costs, reliability, quality, and learning how to use the device. PT/INR issues focused on the frequency of testing, INR fluctuations and individual target (therapeutic) INR level. Other themes noted were INR testing at laboratories, the interactions with healthcare professionals in managing and testing OAT and insurance companies' involvement in acquiring the self-testing equipment. Social issues included the pain and stress of taking and testing for OAT.
Conclusions
Patients' blogs on PT/INR testing provide insightful information that can help in understanding the nature of the experiences and perspectives of patients on self-testing of OAT. The themes identified in this paper highlight the substantial complexities involved in self-testing programmes in the healthcare system. Thus, the issues elicited in this study are very valuable for all stakeholders involved in developing effective self-testing strategies in healthcare that are gaining considerable current momentum particularly for patients with chronic illness.
doi:10.1186/1472-6963-11-25
PMCID: PMC3045880  PMID: 21291542