PMCC PMCC

Search tips
Search criteria

Advanced
Results 1-25 (1411694)

Clipboard (0)
None

Related Articles

1.  Assessment of bone ingrowth potential of biomimetic hydroxyapatite and brushite coated porous E-beam structures 
The bone ingrowth potential of biomimetic hydroxyapatite and brushite coatings applied on porous E-beam structure was examined in goats and compared to a similar uncoated porous structure and a conventional titanium plasma spray coating. Specimens were implanted in the iliac crest of goats for a period of 3 (4 goats) or 15 weeks (8 goats). Mechanical implant fixation generated by bone ingrowth was analyzed by a push out test. Histomorphometry was performed to assess the bone ingrowth depth and bone implant contact. The uncoated and hydroxyapatite-coated cubic structure had significantly higher mechanical strength at the interface compared to the Ti plasma spray coating at 15 weeks of implantation. Bone ingrowth depth was significantly larger for the hydroxyapatite- and brushite-coated structures compared to the uncoated structure. In conclusion, the porous E-beam surface structure showed higher bone ingrowth potential compared to a conventional implant surface after 15 weeks of implantation. Addition of a calcium phosphate coating to the E-beam structure enhanced bone ingrowth significantly. Furthermore, the calcium phosphate coating appears to work as an accelerator for bone ingrowth.
doi:10.1007/s10856-011-4256-0
PMCID: PMC3085057  PMID: 21327405
2.  Evaluation of Biological Properties of Electron Beam Melted Ti6Al4V Implant with Biomimetic Coating In Vitro and In Vivo 
PLoS ONE  2012;7(12):e52049.
Background
High strength porous titanium implants are widely used for the reconstruction of craniofacial defects because of their similar mechanical properties to those of bone. The recent introduction of electron beam melting (EBM) technique allows a direct digitally enabled fabrication of patient specific porous titanium implants, whereas both their in vitro and in vivo biological performance need further investigation.
Methods
In the present study, we fabricated porous Ti6Al4V implants with controlled porous structure by EBM process, analyzed their mechanical properties, and conducted the surface modification with biomimetic approach. The bioactivities of EBM porous titanium in vitro and in vivo were evaluated between implants with and without biomimetic apatite coating.
Results
The physical property of the porous implants, containing the compressive strength being 163 - 286 MPa and the Young’s modulus being 14.5–38.5 GPa, is similar to cortical bone. The in vitro culture of osteoblasts on the porous Ti6Al4V implants has shown a favorable circumstance for cell attachment and proliferation as well as cell morphology and spreading, which were comparable with the implants coating with bone-like apatite. In vivo, histological analysis has obtained a rapid ingrowth of bone tissue from calvarial margins toward the center of bone defect in 12 weeks. We observed similar increasing rate of bone ingrowth and percentage of bone formation within coated and uncoated implants, all of which achieved a successful bridging of the defect in 12 weeks after the implantation.
Conclusions
This study demonstrated that the EBM porous Ti6Al4V implant not only reduced the stress-shielding but also exerted appropriate osteoconductive properties, as well as the apatite coated group. The results opened up the possibility of using purely porous titanium alloy scaffolds to reconstruct specific bone defects in the maxillofacial and orthopedic fields.
doi:10.1371/journal.pone.0052049
PMCID: PMC3525565  PMID: 23272208
3.  The effect of plasma surface treatment on the bioactivity of titanium implant materials (in vitro) 
Background:
The surface of an implantable biomaterial plays a very important role in determining the biocompatibility, osteoinduction, and osteointegration of implants because it is in intimate contact with the host bone and soft tissues.
Objective:
This study was aimed to assess the effect of plasma surface treatment on the bioactivity of titanium alloy (Ti–6Al–4V).
Materials and Methods:
Fifteen titanium alloy samples were used in this study. The samples were divided into three groups (with five samples in each group). Five samples were kept untreated and served as control (group A). Another five plasma samples were sprayed for nitrogen ion implantation on their surfaces (group B) and the last five samples were pre-etched with acid before plasma treatment (group C). All the investigated samples were immersed for 7 days in Hank's balanced salt solution (HBSS) which was used as a simulating body fluid (SBF) at pH 7.4 and 37°C. HBSS was renewed every 3 days. The different surfaces were characterized by X-ray diffraction (XRD), Atomic Force Microscopy (AFM), Scanning Electron Microscopy (SEM), Energy-dispersive X-ray spectroscopy (EDXA), and Fourier Transformation Infrared Spectroscopy (FTIR).
Results:
Nitriding of Ti-alloy samples via plasma nitrogen ion implantation increased the bioactivity of titanium. Moreover, the surface topography affected the chemical structure of the formed apatite. Increasing the surface roughness enhanced the bioactivity of the implant material.
Conclusions:
Nitridation can be exploited as an effective way to promote the formation of bone-like material on the implant surface.
doi:10.4103/2231-0762.171592
PMCID: PMC4784058  PMID: 27011927
Bioactivity; nitridation; nitrogen ion implantation; plasma; plasma surface treatment; surface roughness; surface treatment
4.  Osteogenic Protein-1 for Long Bone Nonunion 
Executive Summary
Objective
To assess the efficacy of osteogenic protein-1 (OP-1) for long bone nonunion.
Clinical Need
Although most fractures heal within a normal period, about 5% to 10% do not heal and are classified as delayed or nonunion fractures. Nonunion and segmental bone loss after fracture, reconstructive surgery, or lesion excision can present complex orthopedic problems, and the multiple surgical procedures often needed are associated with patient morbidity and reduced quality of life.
Many factors contribute to the pathogenesis of a delayed union or nonunion fractures, including deficiencies of calcium, vitamin D, or vitamin C, and side effects of medications such as anticoagulants, steroids, some anti-inflammatory drugs, and radiation. It has been shown that smoking interferes with bone repair in several ways.
Incidence of Nonunion and Delayed Union Cases
An estimated 5% to 10% of fractures do not heal properly and go on to delayed union or nonunion. If this overall estimate of incidence were applied to the Ontario population1, the estimated number of delayed union or nonunion in the province would be between 3,863 and 7,725.
Treatment of Nonunion Cases
The treatment of nonunion cases is a challenge to orthopedic surgeons. However, the basic principle behind treatment is to provide both mechanical and biological support to the nonunion site.
Fracture stabilization and immobilization is frequently used with the other treatment modalities that provide biological support to the fractured bone. Biological support includes materials that could be served as a source of osteogenic cells (osteogenesis), a stimulator of mesenchymal cells (osteoinduction), or a scaffold-like structure (osteoconduction).
The capacity to heal a fracture is a latent potential of the stromal stem cells, which synthesize new bone. This process has been defined as osteogenesis. Activation of the stem cells to initiate osteogenic response and to differentiate into bone-forming osteoblasts is called osteoinduction. These 2 properties accelerate the rate of fracture healing or reactivate the ineffective healing process. Osteoconduction occurs when passive structures facilitate the migration of osteoprogenitor cells, the perivascular tissue, and capillaries into these structures.
Bone Grafts and Bone Graft Substitutes
Bone graft and bone graft substitutes have one or more of the following components:
Undifferentiated stem cells
Growth factors
Structural lattice
Undifferentiated stem cells are unspecialized, multipotential cells that can differentiate into a variety of specialized cells. They can also replicate themselves. The role of stem cells is to maintain and repair the tissue in which they are residing. A single stem cell can generate all cell types of that tissue. Bone marrow is a source of at least 2 kinds of stem cells. Hematopoietic stem cells that form all types of blood cells, and bone marrow stromal stem cells that have osteogenic properties and can generate bone, cartilage, and fibrous tissue.
Bone marrow has been used to stimulate bone formation in bone defects and cases of nonunion fractures. Bone marrow can be aspirated from the iliac crest and injected percutaneously with fluoroscopic guidance into the site of the nonunion fracture. The effectiveness of this technique depends on the number and activity of stem cells in the aspirated bone marrow. It may be possible to increase the proliferation and speed differentiation of stem cells by exposing them to growth factor or by combining them with collagen.
Many growth factors and cytokines induced in response to injury are believed to have a considerable role in the process of repair. Of the many bone growth factors studied, bone morphogenetics (BMPs) have generated the greatest attention because of their osteoinductive potential. The BMPs that have been most widely studied for their ability to induce bone regeneration in humans include BMP-2 and BMP-7 (osteogenic protein). Human osteogenic protein-1 (OP-1) has been cloned and produced with recombinant technology and is free from the risk of infection or allergic reaction.
The structural lattice is osteoconductive; it supports the ingrowth of developing capillaries and perivascular tissues. Three distinct groups of structural lattice have been identified: collagen, calcium sulphate, and calcium phosphate. These materials can be used to replace a lost segment of bone.
Grafts Used for Nonunion
Autologous bone graft is generally considered the gold standard and the best material for grafting because it contains several elements that are critical in promoting bone formation, including osteoprogenitor cells, the matrix, and bone morphogenetic proteins. The osteoconductive property of cancellous autograft is related to the porosity of bone. The highly porous, scaffold-like structure of the graft allows host osteoblasts and host osteoprogenitor cells to migrate easily into the area of the defect and to begin regeneration of bone. Sources of cancellous bone are the iliac crest, the distal femur, the greater trochanter, and the proximal tibia. However, harvesting the autologous bone graft is associated with postoperative pain at the donor site, potential injury to the surrounding arteries, nerves, and tissues, and the risk of infection. Thus the development of synthetic materials with osteoconductive and osteoinductive properties that can eliminate the need for harvesting has become a major goal of orthopedic research.
Allograft is the graft of tissue between individuals who are of the same species but are of a disparate genotype. Allograft has osteoconductive and limited osteoinductive properties. Demineralized bone matrix (DBM) is human cortical and cancellous allograft. These products are prepared by acid extraction of allograft bone, resulting in the loss of most of the mineralized component while collagen and noncollagenous proteins, including growth factors, are retained. Figures 1 to 5 demonstrate the osteogenic, osteoinduction, and osteoconduction properties of autologous bone graft, allograft, OP-1, bone graft substitutes, and bone marrow.
Autologous Bone Graft
Osteogenic Protein-1
Allograft bone and Demineralized Bone Matrix
Bone Graft Substitutes
Autologous Bone Marrow Graft
New Technology Being Reviewed: Osteogenic Protein-1
Health Canada issued a Class IV licence for OP-1 in June 2004 (licence number 36320). The manufacturer of OP-1 is Stryker Biotech (Hapkinton, MA).
The United States Food and Drug Administration (FDA) issued a humanitarian device exemption for the application of the OP-1 implant as an “alternative to autograft in recalcitrant long bone nonunions where use of autograft is unfeasible and alternative treatments have failed.” Regulatory agencies in Europe, Australia, and New Zealand have permitted the use of this implant in specific cases, such as in tibial nonunions, or in more general cases, such as in long bone nonunions.
According to the manufacturer, OP-1 is indicated for the treatment of long bone nonunions. It is contraindicated in the patient has a hypersensitivity to the active substance or collagen, and it should not be applied at the site of a resected tumour that is at or near the defect or fracture. Finally, it should not be used in patients who are skeletally immature (< 18 years of age), or if there is no radiological evidence of closure of epiphysis.
Review Strategy
Objective
To summarize the safety profile and effectiveness of OP-1 in the treatment of cases of long bone nonunion and bone defects
To compare the effectiveness and cost effectiveness of OP-1 in the treatment of long bone nonunions and bone defects with the alternative technologies, particularly the gold standard autologous bone graft.
Literature Search
International Network of Agencies for Health Technology Assessments (INAHTA), the Cochrane Database of Systematic Reviews and the CCTR (formerly Cochrane Controlled Trials Register) were searched for health technology assessments. MEDLINE, EMBASE, Medline In Process and Other Non-Indexed Citations were searched from January 1, 1996 to January 27, 2004 for studies on OP-1. The search was limited to English-language articles and human studies. The search yielded 47 citations. Three studies met inclusion criteria (2 RCTs and 1 Ontario-based study presented at an international conference.
Summary of Findings
Friedlaender et al. conducted a prospective, randomized, partially blinded clinical trial on the treatment tibial nonunions with OP-1. Tibial nonunions were chosen for this study because of their high frequency, challenging treatment requirements, and substantial morbidity. All of the nonunions were at least 9 months old and had shown no progress toward healing over the previous 3 months. The patients were randomized to receive either treatment with autologous bone grafting or treatment with OP-1 in a type-1 collagen carrier. Both groups received reduction and fixation with an intramedullary rod. Table 1 summarizes the clinical outcomes of this study.
Outcomes in a Randomized Clinical Trial on Tibial Nonunions: Osteogenic Protein-1 versus Autologous Bone Grafting
Clinical success was defined as full weight-bearing, loss of severe pain at the fracture site on weight-bearing, and no further surgical treatment to enhance fracture repair.
The results of this study demonstrated that recombinant OP-1 is associated with substantial clinical and radiographic success for the treatment of tibial nonunions when used with intramedullary rod fixation. No adverse event related to sensitization was reported. Five per cent of the patients in the OP-1 group had circulating antibodies against type 1 collagen. Only 10% of the patients had a low level of anti-OP-1 antibodies, and all effects were transient. Furthermore, the success rate with the OP-1 implant was comparable with those achieved with autograft at 9 and 24 months follow-up. Eighty-two per cent of patients were successful at 24 months follow-up in both groups.
Statistically significant increased blood loss in the group treated with the autograft was observed (P = .049). Patients treated with autograft had longer operation and hospitalization times. All patients in the autograft group had pain at the donor site after surgery, and more than 80% judged their postoperative pain as moderate or severe. At their 6-month visit, 20% of the patients in the autograft group had persistent pain, mild or moderate in nature, at the donor site. This number fell to 13% at 12 months.
All patients in each of the groups had at least 1 adverse event that wasn’t serious, such as fever, nausea and vomiting, leg edema, discomfort, and bruising at the operative site. The incidence of these events was similar in both groups. Serious adverse events were observed in 44% of both groups, none of which were considered related to the OP-1 implant or autograft.
On the basis of this data, the FDA issued a humanitarian device exemption for the application of OP-1 implant as an alternative to autograft in recalcitrant long bone nonunions when the use of autograft is unfeasible and alternative treatments have failed.
Study on Fibular Defects
Geesink et al. investigated the osteogenic activity of OP-1 by assessing its value in bridging fibular defects made at the time of tibial osteotomy for varus or valgus deformity of the knee. This study had 2 phases and included 12 patients in each phase. Each phase included 12 patients (6 in each group). Patients in the first phase received either DBM or were left untreated. Patients in the second phase received either OP-1 on collagen type-1 or collagen type-1 alone.
Radiological and Dual Energy X-ray Absorptiometry (DEXA) evaluation showed that in patients in whom the defect was left untreated, no formation of bone occurred. At 12 months follow-up, new bone formation with bridging occurred in 4 of the 6 patients in DMB group, and 5 of the 6 patients in OP-1 group. One patient in OP-1 group did not show any evidence of new bone formation at any point during the study.
Ontario Pilot Study
A prospective pilot study was conducted in Ontario, Canada to investigate the safety and efficacy of OP-1 for the treatment of recalcitrant long bone nonunions. The study looked at 15 patients with complex, recalcitrant, long bone nonunions whose previous treatment had failed. The investigators concluded that this bone graft substitute appears to be safe and effective in providing sufficient biological stimulation in difficult to treat nonunions. Results of a more complete study on 70 patients are ready for publication. According to the principal investigator, OP-1 was 90% effective in inducing bone formation and bone healing in this sample.
Alternative Technologies
The Medical Advisory Secretariat conducted a literature search from January 1, 2000 to February 28, 2005 to identify studies on nonunions/bone defects that had been treated with alternative technologies. A review of these studies showed that, in addition to the gold standard autologous bone marrow grafting, bone allografts, demineralized bone matrices, bone graft substitutes, and autologous bone marrow have been used for treatment of nonunions and bone defects. These studies were categorized according to the osteoinductive, osteoconductive, and osteogenesis properties of the technologies studied.
A review of these studies showed that bone allografts have been used mostly in various reconstruction procedures to restore the defect after excavating a bone lesion. Two studies investigated the effectiveness of DBM in healing fracture nonunions. Calcium phosphate and calcium sulphate have been used mostly for repair of bone defects.
Several investigators have looked at the use of autologous bone marrow for treatment of long bone nonunions. The results of these studies show that method of percutaneous bone marrow grafting is highly effective in the treatment of long bone nonunions. In a total of 301 fractures across all studies, 268 (89%) healed with a mean healing time of 2.5 to 8 months. This healing time as derived from these case series is less than the timing of the primary end point in Friedlaender’s study (9 months). Table 2 summarizes the results of these studies. Table 2 summarizes the results of these studies.
Studies that used Percutaneous Bone Marrow Grafting for Treatment of Nonunions
Economic Analysis
Based on annual estimated incidence of long-bone nonunion of 3,863 - 7,725, the annual hospitalization costs associated with this condition is between $21.2 and $42.3 million based on a unit cost of $5,477 per hospital separation. When utilized, the device, a single vial of OP-1, is approximately $5,000 and if adopted universally in Ontario, the total device costs would be in the range of $19.3 - $38.6 million annually. The physician fee for harvest, insertion of bone, or OP-1 is $193 and is $193 for autologous bone marrow transplantation. Total annual physician costs are expected to be in the range of from $0.7 million to $1.3 million per year. Expenditures associated with long-bone nonunion are unlikely to increase since incidence of long-bone nonunion is unlikely to change in the future. However, the rate of uptake of OP-1 could have a significant impact on costs if the uptake were large.
The use of OP-1 and autologous bone marrow transplantation may offset pain medication costs compared with those associated with autologous bone harvest given that the former procedures do not involve the pain associated with the bone harvest site. However, given that this pain is normally not permanent, the overall offset is likely to be small. There are likely to be smaller OHIP costs associated with OP-1 than bone-harvest procedures given that only 1, rather than 2, incisions are needed when comparing the former with the latter procedure. This offset could amount to between $0.3 million to $0.7 million annually.
No data on the cost-effectiveness of OP-1 is available.
PMCID: PMC3382627  PMID: 23074475
5.  Removing Biofilms from Microstructured Titanium Ex Vivo: A Novel Approach Using Atmospheric Plasma Technology 
PLoS ONE  2011;6(10):e25893.
The removal of biofilms from microstructured titanium used for dental implants is a still unresolved challenge. This experimental study investigated disinfection and removal of in situ formed biofilms from microstructured titanium using cold atmospheric plasma in combination with air/water spray. Titanium discs (roughness (Ra): 1.96 µm) were exposed to human oral cavities for 24 and 72 hours (n = 149 each) to produce biofilms. Biofilm thickness was determined using confocal laser scanning microscopy (n = 5 each). Plasma treatment of biofilms was carried out ex vivo using a microwave-driven pulsed plasma source working at temperatures from 39 to 43°C. Following plasma treatment, one group was air/water spray treated before re-treatment by second plasma pulses. Vital microorganisms on the titanium surfaces were identified by contact culture (Rodac agar plates). Biofilm presence and bacterial viability were quantified by fluorescence microscopy. Morphology of titanium surfaces and attached biofilms was visualized by scanning electron microscopy (SEM). Total protein amounts of biofilms were colorimetrically quantified. Untreated and air/water treated biofilms served as controls. Cold plasma treatment of native biofilms with a mean thickness of 19 µm (24 h) to 91 µm (72 h) covering the microstructure of the titanium surface caused inactivation of biofilm bacteria and significant reduction of protein amounts. Total removal of biofilms, however, required additional application of air/water spray, and a second series of plasma treatment. Importantly, the microstructure of the titanium discs was not altered by plasma treatment. The combination of atmospheric plasma and non-abrasive air/water spray is applicable for complete elimination of oral biofilms from microstructured titanium used for dental implants and may enable new routes for the therapy of periimplant disease.
doi:10.1371/journal.pone.0025893
PMCID: PMC3189945  PMID: 22016784
6.  Bone integration capability of nanopolymorphic crystalline hydroxyapatite coated on titanium implants 
The mechanism by which hydroxyapatite (HA)-coated titanium promotes bone–implant integration is largely unknown. Furthermore, refining the fabrication of nano-structured HA to the level applicable to the mass production process for titanium implants is challenging. This study reports successful creation of nanopolymorphic crystalline HA on microroughened titanium surfaces using a combination of flame spray and low-temperature calcination and tests its biological capability to enhance bone–implant integration. Sandblasted microroughened titanium implants and sandblasted + HA-coated titanium implants were subjected to biomechanical and histomorphometric analyses in a rat model. The HA was 55% crystallized and consisted of nanoscale needle-like architectures developed in various diameters, lengths, and orientations, which resulted in a 70% increase in surface area compared to noncoated microroughened surfaces. The HA was free from impurity contaminants, with a calcium/phosphorus ratio of 1.66 being equivalent to that of stoichiometric HA. As compared to microroughened implants, HA-coated implants increased the strength of bone–implant integration consistently at both early and late stages of healing. HA-coated implants showed an increased percentage of bone–implant contact and bone volume within 50 μm proximity of the implant surface, as well as a remarkably reduced percentage of soft tissue intervention between bone and the implant surface. In contrast, bone volume outside the 50 μm border was lower around HA-coated implants. Thus, this study demonstrated that the addition of pure nanopolymorphic crystalline HA to microroughened titanium not only accelerates but also enhances the level of bone–implant integration and identified the specific tissue morphogenesis parameters modulated by HA coating. In particular, the nanocrystalline HA was proven to be drastic in increasing osteoconductivity and inhibiting soft tissue infiltration, but the effect was limited to the immediate microenvironment surrounding the implant.
doi:10.2147/IJN.S28082
PMCID: PMC3284227  PMID: 22359461
osseointegration; dental and orthopedic implant; nanotechnology; bone–implant integration; HA; calcium phosphate
7.  Biomechanical and Histological Evaluation of Roughened Surface Titanium Screws Fabricated by Electron Beam Melting 
PLoS ONE  2014;9(4):e96179.
Background
Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae.
Methods
Roughened surface titanium screws, fabricated by electron beam melting, and conventional smooth surface titanium screws were implanted into sheep for 6 or 12 weeks (groups A and B, respectively). Bone ingrowth and implant stability were assessed with three-dimensional imaging and reconstruction, as well as histological and biomechanical tests.
Results
No screws in either group showed signs of loosening. Fibrous tissue formation could be seen around the screws at 6 weeks, which was replaced with bone at 12 weeks. Bone volume/total volume, bone surface area/bone volume, and the trabecular number were significantly higher for a define region of interest surrounding the roughened screws than that surrounding the smooth screws at 12 weeks. Indeed, for roughened screws, trabecular number was significantly higher at 12 weeks than at 6 weeks. On mechanical testing, the maximum pullout strength was significantly higher at 12 weeks than at 6 weeks, as expected; however, no significant differences were found between smooth and roughened screws at either time point. The maximum torque to extract the roughened screws was higher than that required for the smooth screws.
Conclusions
Electron beam melting is a simple and effective method for producing a roughened surface on titanium screws. After 12 weeks, roughened titanium screws demonstrated a high degree of osseointegration and increased torsional resistance to extraction over smooth titanium screws.
doi:10.1371/journal.pone.0096179
PMCID: PMC4005762  PMID: 24788866
8.  Cancellous Bone Osseointegration Is Enhanced by In Vivo Loading 
Tissue Engineering. Part C, Methods  2010;16(6):1399-1406.
Biophysical stimuli may be an effective therapy to counteract age-related changes in bone structure that affect the primary stability of implants used in joint replacement or fracture fixation. The influence of controlled mechanical loading on osseointegration was investigated using an in vivo device implanted in the distal lateral femur of 12 male rabbits. Compressive loads (1 MPa, 1 Hz, 50 cycles/day, 4 weeks) were applied to a porous titanium foam implant and the underlying cancellous bone. The contralateral limbs served as nonloaded controls. Backscattered electron imaging indicated that the amount of bone ingrowth was significantly greater in the loaded limb than in the nonloaded control limb, whereas the amount of underlying cancellous periprosthetic bone was similar. No significant difference in the mineral apposition rate of the bone ingrowth or periprosthetic bone was measured in the loaded compared to the control limb. Histological analysis demonstrated newly formed woven bone in direct apposition to the implant coating, with a lack of fibrous tissue at the implant–periprosthetic bone interface in both loaded and nonloaded implants. The lack of fibrous tissue demonstrates that mechanical stimulation using this model significantly enhanced cancellous bone ingrowth without the detrimental effects of micromotion. These results suggest that biophysical therapy should be further investigated to augment current treatments to enhance long-term fixation of orthopedic devices. Additionally, this novel in vivo loading model can be used to further investigate the influence of biophysical stimulation on other tissue engineering approaches requiring bone ingrowth into both metallic and nonmetallic cell-seeded scaffolds.
doi:10.1089/ten.tec.2009.0776
PMCID: PMC2988627  PMID: 20367497
9.  Osseointegration in arthroplasty: can simvastatin promote bone response to implants? 
International Orthopaedics  2007;33(3):855-859.
Cementless fixation depends on bone ingrowth for long-term success. Simvastatin as a lipid lowering agent has been demonstrated to have osteoanabolic effects. This study was designed to measure the possible effect of simvastatin on implant osseointegration. Bilateral femoral implantation of titanium cylinders was performed in 20 rabbits. Blood lipid levels were measured pre- and postoperatively. Scanning electron microscopy (SEM) was used to measure the percentage of the surface of each implant in contact with bone and mechanical pull-out testing was performed. The blood lipid levels were significantly reduced in the simvastatin group. Histomorphometric examination revealed increased bone ingrowth and mechanical examination showed increased interface strength in the simvastatin group. Mechanical and histological data showed superior stability and osseous adaptation at the bone/implant interface for the simvastatin group. We conclude that simvastatin has potential as a means of enhancing bone ingrowth, which is a key factor in the longevity of cementless implants.
doi:10.1007/s00264-007-0490-y
PMCID: PMC2903108  PMID: 18157535
10.  Ag-plasma modification enhances bone apposition around titanium dental implants: an animal study in Labrador dogs 
Dental implants with proper antibacterial ability as well as ideal osseointegration are being actively pursued. The antimicrobial ability of titanium implants can be significantly enhanced via modification with silver nanoparticles (Ag NPs). However, the high mobility of Ag NPs results in their potential cytotoxicity. The silver plasma immersion ion-implantation (Ag-PIII) technique may remedy the defect. Accordingly, Ag-PIII technique was employed in this study in an attempt to reduce the mobility of Ag NPs and enhance osseointegration of sandblasted and acid-etched (SLA) dental implants. Briefly, 48 dental implants, divided equally into one control and three test groups (further treated by Ag-PIII technique with three different implantation parameters), were inserted in the mandibles of six Labrador dogs. Scanning electron microscopy, X-ray photoelectron spectroscopy, and inductively coupled plasma optical emission spectrometry were used to investigate the surface topography, chemical states, and silver release of SLA- and Ag-PIII-treated titanium dental implants. The implant stability quotient examination, Microcomputed tomography evaluation, histological observations, and histomorphometric analysis were performed to assess the osseointegration effect in vivo. The results demonstrated that normal soft tissue healing around dental implants was observed in all the groups, whereas the implant stability quotient values in Ag-PIII groups were higher than that in the SLA group. In addition, all the Ag-PIII groups, compared to the SLA-group, exhibited enhanced new bone formation, bone mineral density, and trabecular pattern. With regard to osteogenic indicators, the implants treated with Ag-PIII for 30 minutes and 60 minutes, with the diameter of the Ag NPs ranging from 5–25 nm, were better than those treated with Ag-PIII for 90 minutes, with the Ag NPs diameter out of that range. These results suggest that Ag-PIII technique can reduce the mobility of Ag NPs and enhance the osseointegration of SLA surfaces and have the potential for future use.
doi:10.2147/IJN.S73467
PMCID: PMC4298332  PMID: 25609967
surface modification; micro/nanostructure; silver; ion implantation; osseointegration
11.  Bacterial inactivation/sterilization by argon plasma treatment on contaminated titanium implant surfaces:In vitro study 
Background
Surface treatment by argon plasma is widely used as the last step of the manufacturing process of titanium implant fixtures before their sterilization by gamma rays. The possibility of using such a technology in the daily clinical practice is particularly fascinating. The aim of the present study was to assess the effects of the argon plasma treatment on different titanium implant surfaces previously exposed In vitro to bacterial contamination.
Material and Methods
Sterile c.p. titanium implant discs with turned (T, Sa: 0.8 µm ), sandblasted/acid-etched (SAE, Sa: 1.3 µm) and titanium plasma sprayed (TPS, Sa: 3.0µm) surface were used in this study. A strain of Aggregatibacter actinomycetemcomitans ATCC3718 was grown at 37°C under anaerobic conditions for 24 h and then transferred on six discs for each of the three surface types. After 24 hours, a half of the contaminated discs (control group) were directly used to evaluate the colony forming units (CFUs). The other half of the contaminated discs (test group) were treated in an argon plasma chamber for 12 minutes at room temperature prior to be analyzed for CFU counting. All assays were performed using triplicate samples of each material in 3 different experiments.
Results
When the CFU counting was carried out on control discs, a total of 1.50x106±1.4x105, 1.55x106±7.07x104 and 3.15x106±2.12x105 CFU was respectively assessed for T, SAE and TPS discs, without statistically significant differences among the three surfaces. On the contrary, any trace of bacterial contamination was assessed for titanium discs treated in the argon plasma chamber prior to be analyzed, irrespectively to the implant surface tested.
Conclusions
Within the limit of this study, reported data suggested that the argon plasma technology could be efficiently used to decontaminate/sterilize previously infected titanium implant surfaces.
Key words:Argon plasma, titanium implant surface, Aggregatibacter actinomycetemcomitans.
doi:10.4317/medoral.20845
PMCID: PMC4765757  PMID: 26595834
12.  Osseointegration of zirconia implants compared with titanium: an in vivo study 
Head & Face Medicine  2008;4:30.
Background
Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface modifications have been developed to improve osseous healing. Zirconia-based implants were introduced into dental implantology as an altenative to titanium implants. Zirconia seems to be a suitable implant material because of its tooth-like colour, its mechanical properties and its biocompatibility. As the osseointegration of zirconia implants has not been extensively investigated, the aim of this study was to compare the osseous healing of zirconia implants with titanium implants which have a roughened surface but otherwise similar implant geometries.
Methods
Forty-eight zirconia and titanium implants were introduced into the tibia of 12 minipigs. After 1, 4 or 12 weeks, animals were sacrificed and specimens containing the implants were examined in terms of histological and ultrastructural techniques.
Results
Histological results showed direct bone contact on the zirconia and titanium surfaces. Bone implant contact as measured by histomorphometry was slightly better on titanium than on zirconia surfaces. However, a statistically significant difference between the two groups was not observed.
Conclusion
The results demonstrated that zirconia implants with modified surfaces result in an osseointegration which is comparable with that of titanium implants.
doi:10.1186/1746-160X-4-30
PMCID: PMC2614983  PMID: 19077228
13.  The pathway to intelligent implants: osteoblast response to nano silicon-doped hydroxyapatite patterning 
Bioactive hydroxyapatite (HA) with addition of silicon (Si) in the crystal structure (silicon-doped hydroxyapatite (SiHA)) has become a highly attractive alternative to conventional HA in bone replacement owing to the significant improvement in the in vivo bioactivity and osteoconductivity. Nanometre-scaled SiHA (nanoSiHA), which closely resembles the size of bone mineral, has been synthesized in this study. Thus, the silicon addition provides an extra chemical cue to stimulate and enhance bone formation for new generation coatings, and the next stage in metallic implantation design is to further improve cellular adhesion and proliferation by control of cell alignment. Topography has been found to provide a powerful set of signals for cells and form contact guidance. Using the recently developed novel technique of template-assisted electrohydrodynamic atomization (TAEA), patterns of pillars and tracks of various dimensions of nanoSiHA were achieved. Modifying the parameters of TAEA, the resolution of pattern structures was controlled, enabling the topography of a substrate to be modified accordingly. Spray time, flow rate and distance between the needle and substrate were varied to improve the pattern formation of pillars and tracks. The 15 min deposition time provided the most consistent patterned topography with a distance of 50 mm and flow rate of 4 µl min−1. A titanium substrate was patterned with pillars and tracks of varying widths, line lengths and distances under the optimized TAEA processing condition. A fast bone-like apatite formation rate was found on nanoSiHA after immersion in simulated body fluid, thus demonstrating its high in vitro bioactivity. Primary human osteoblast (HOB) cells responded to SiHA patterns by stretching of the filopodia between track and pillar, attaching to the apex of the pillar pattern and stretching between two. HOB cells responded to the track pattern by elongating along and between the track, and the length of HOB cells was proportional to the gaps between track patterns, but this relationship was not observed on the pillar patterns. The study has therefore provided an insight for future design of next generation implant surfaces to control and guide cellular responses, while TAEA patterning provides a controllable technique to provide topography to medical implants.
doi:10.1098/rsif.2010.0548
PMCID: PMC3061100  PMID: 21208969
patterning; electrohydrodynamic atomization; surface topography
14.  Reality of Dental Implant Surface Modification: A Short Literature Review 
Screw-shaped endosseous implants that have a turned surface of commercially pure titanium have a disadvantage of requiring a long time for osseointegration while those implants have shown long-term clinical success in single and multiple restorations. Titanium implant surfaces have been modified in various ways to improve biocompatibility and accelerate osseointegration, which results in a shorter edentulous period for a patient. This article reviewed some important modified titanium surfaces, exploring the in vitro, in vivo and clinical results that numerous comparison studies reported. Several methods are widely used to modify the topography or chemistry of titanium surface, including blasting, acid etching, anodic oxidation, fluoride treatment, and calcium phosphate coating. Such modified surfaces demonstrate faster and stronger osseointegration than the turned commercially pure titanium surface. However, there have been many studies finding no significant differences in in vivo bone responses among the modified surfaces. Considering those in vivo results, physical properties like roughening by sandblasting and acid etching may be major contributors to favorable bone response in biological environments over chemical properties obtained from various modifications including fluoride treatment and calcium phosphate application. Recently, hydrophilic properties added to the roughened surfaces or some osteogenic peptides coated on the surfaces have shown higher biocompatibility and have induced faster osseointegration, compared to the existing modified surfaces. However, the long-term clinical studies about those innovative surfaces are still lacking.
doi:10.2174/1874120701408010114
PMCID: PMC4231373  PMID: 25400716
Anodic oxidation; BMP; fluoride; functional peptide; hydrophilicity; implant surface; SLA; surface modification.
15.  In Vitro and In Vivo Evaluation of Zinc-Modified Ca–Si-Based Ceramic Coating for Bone Implants 
PLoS ONE  2013;8(3):e57564.
The host response to calcium silicate ceramic coatings is not always favorable because of their high dissolution rates, leading to high pH within the surrounding physiological environment. Recently, a zinc-incorporated calcium silicate-based ceramic Ca2ZnSi2O7 coating, developed on a Ti-6Al-4V substrate using plasma-spray technology, was found to exhibit improved chemical stability and biocompatibility. This study aimed to investigate and compare the in vitro response of osteoblastic MC3T3-E1 cells cultured on Ca2ZnSi2O7 coating, CaSiO3 coating, and uncoated Ti-6Al-4V titanium control at cellular and molecular level. Our results showed Ca2ZnSi2O7 coating enhanced MC3T3-E1 cell attachment, proliferation, and differentiation compared to CaSiO3 coating and control. In addition, Ca2ZnSi2O7 coating increased mRNA levels of osteoblast-related genes (alkaline phosphatase, procollagen α1(I), osteocalcin), insulin-like growth factor-I (IGF-I), and transforming growth factor-β1 (TGF-β1). The in vivo osteoconductive properties of Ca2ZnSi2O7 coating, compared to CaSiO3 coating and control, was investigated using a rabbit femur defect model. Histological and histomorphometrical analysis demonstrated new bone formation in direct contact with the Ca2ZnSi2O7 coating surface in absence of fibrous tissue and higher bone-implant contact rate (BIC) in the Ca2ZnSi2O7 coating group, indicating better biocompatibility and faster osseointegration than CaSiO3 coated and control implants. These results indicate Ca2ZnSi2O7 coated implants have applications in bone tissue regeneration, since they are biocompatible and able to osseointegrate with host bone.
doi:10.1371/journal.pone.0057564
PMCID: PMC3590211  PMID: 23483914
16.  The Otto Aufranc Award: Demineralized Bone Matrix Around Porous Implants Promotes Rapid Gap Healing and Bone Ingrowth 
Background
Noncemented revision arthroplasty is often complicated by the presence of bone implant gaps that reduce initial stability and biologic fixation. Demineralized bone matrix has osteoinductive properties and therefore the potential to enhance gap healing and porous implant fixation.
Questions/purposes
We determined at what times and to what extent demineralized bone matrix promotes gap healing and bone ingrowth around a porous implant.
Methods
We inserted porous titanium implants into the proximal metaphyses of canine femora and humeri, with an initial 3-mm gap between host cancellous bone and implants. We left the gaps empty (control; n = 12) or filled them with either demineralized bone matrix (n = 6) or devitalized demineralized bone matrix (negative control; n = 6) and left them in situ for 4 or 12 weeks. We quantified volume healing of the gap with new bone using three-dimensional micro-CT scanning and quantified apposition and ingrowth using backscattered scanning electron microscopy.
Results
The density of bone inside gaps filled with demineralized bone matrix reached 64% and 93% of surrounding bone density by 4 and 12 weeks, respectively. Compared with empty controls and negative controls at 4 and 12 weeks, gap healing using demineralized bone matrix was two to three times greater and bone ingrowth and apposition were up to 15 times greater.
Conclusions
Demineralized bone matrix promotes rapid bone ingrowth and gap healing around porous implants.
Clinical Relevance
Demineralized bone matrix has potential for enhancing implant fixation in revision arthroplasty.
doi:10.1007/s11999-011-2011-y
PMCID: PMC3254744  PMID: 21863397
17.  Microgrooves on titanium surface affect peri-implant cell adhesion and soft tissue sealing; an in vitro and in vivo study 
Purpose
With the significance of stable adhesion of alveolar bone and peri-implant soft tissue on the surface of titanium for successful dental implantation procedure, the purpose of this study was to apply microgrooves on the titanium surface and investigate their effects on peri-implant cells and tissues.
Methods
Three types of commercially pure titanium discs were prepared; machined-surface discs (A), sandblasted, large-grit, acid-etched (SLA)-treated discs (B), SLA and microgroove-formed discs (C). After surface topography of the discs was examined by confocal laser scanning electron microscopy, water contact angle and surface energy were measured. Human gingival fibroblasts (hGFs) and murine osteoblastic cells (MC3T3-E1) were seeded onto the titanium discs for immunofluorescence assay of adhesion proteins. Commercially pure titanium implants with microgrooves on the coronal microthreads design were inserted into the edentulous mandible of beagle dogs. After 2 weeks and 6 weeks of implant insertion, the animal subjects were euthanized to confirm peri-implant tissue healing pattern in histologic specimens.
Results
Group C presented the lowest water contact angle (62.89±5.66 θ), highest surface energy (45±1.2 mN/m), and highest surface roughness (Ra=22.351±2.766 µm). The expression of adhesion molecules of hGFs and MC3T30E1 cells was prominent in group C. Titanium implants with microgrooves on the coronal portion showed firm adhesion to peri-implant soft tissue.
Conclusions
Microgrooves on the titanium surface promoted the adhesion of gingival fibroblasts and osteoblastic cells, as well as favorable peri-implant soft tissue sealing.
Graphical Abstract
doi:10.5051/jpis.2015.45.3.120
PMCID: PMC4485062  PMID: 26131372
Cell adhesion; Dental implants; Titanium; Wound healing
18.  Porous Surface Modified Bioactive Bone Cement for Enhanced Bone Bonding 
PLoS ONE  2012;7(8):e42525.
Background
Polymethylmethacrylate bone cement cannot provide an adhesive chemical bonding to form a stable cement-bone interface. Bioactive bone cements show bone bonding ability, but their clinical application is limited because bone resorption is observed after implantation. Porous polymethylmethacrylate can be achieved with the addition of carboxymethylcellulose, alginate and gelatin microparticles to promote bone ingrowth, but the mechanical properties are too low to be used in orthopedic applications. Bone ingrowth into cement could decrease the possibility of bone resorption and promote the formation of a stable interface. However, scarce literature is reported on bioactive bone cements that allow bone ingrowth. In this paper, we reported a porous surface modified bioactive bone cement with desired mechanical properties, which could allow for bone ingrowth.
Materials and Methods
The porous surface modified bioactive bone cement was evaluated to determine its handling characteristics, mechanical properties and behavior in a simulated body fluid. The in vitro cellular responses of the samples were also investigated in terms of cell attachment, proliferation, and osteoblastic differentiation. Furthermore, bone ingrowth was examined in a rabbit femoral condyle defect model by using micro-CT imaging and histological analysis. The strength of the implant–bone interface was also investigated by push-out tests.
Results
The modified bone cement with a low content of bioactive fillers resulted in proper handling characteristics and adequate mechanical properties, but slightly affected its bioactivity. Moreover, the degree of attachment, proliferation and osteogenic differentiation of preosteoblast cells was also increased. The results of the push-out test revealed that higher interfacial bonding strength was achieved with the modified bone cement because of the formation of the apatite layer and the osseointegration after implantation in the bony defect.
Conclusions
Our findings suggested a new bioactive bone cement for prosthetic fixation in total joint replacement.
doi:10.1371/journal.pone.0042525
PMCID: PMC3414445  PMID: 22905143
19.  Strain driven fast osseointegration of implants 
Background
Although the bone's capability of dental implant osseointegration has clinically been utilised as early as in the Gallo-Roman population, the specific mechanisms for the emergence and maintenance of peri-implant bone under functional load have not been identified. Here we show that under immediate loading of specially designed dental implants with masticatory loads, osseointegration is rapidly achieved.
Methods
We examined the bone reaction around non- and immediately loaded dental implants inserted in the mandible of mature minipigs during the presently assumed time for osseointegration. We used threaded conical titanium implants containing a titanium2+ oxide surface, allowing direct bone contact after insertion. The external geometry was designed according to finite element analysis: the calculation showed that physiological amplitudes of strain (500–3,000 ustrain) generated through mastication were homogenously distributed in peri-implant bone. The strain-energy density (SED) rate under assessment of a 1 Hz loading cycle was 150 Jm-3 s-1, peak dislocations were lower then nm.
Results
Bone was in direct contact to the implant surface (bone/implant contact rate 90%) from day one of implant insertion, as quantified by undecalcified histological sections. This effect was substantiated by ultrastructural analysis of intimate osteoblast attachment and mature collagen mineralisation at the titanium surface. We detected no loss in the intimate bone/implant bond during the experimental period of either control or experimental animals, indicating that immediate load had no adverse effect on bone structure in peri-implant bone.
Conclusion
In terms of clinical relevance, the load related bone reaction at the implant interface may in combination with substrate effects be responsible for an immediate osseointegration state.
doi:10.1186/1746-160X-1-6
PMCID: PMC1277014  PMID: 16270927
20.  Total disc replacement arthroplasty using the AcroFlex lumbar disc: a non-human primate model 
European Spine Journal  2002;11(Suppl 2):S115-S123.
Abstract.
Using a non-human primate model, the current study was undertaken to investigate the efficacy of the AcroFlex lumbar disc as an intervertebral disc prosthesis, based on biomechanical, histopathologic and histomorphometric analyses. A total of 20 mature male baboons (Papio cynocephalus, mean weight 30 kg) were randomized into two equal groups based on post-operative time periods of 6 (n=10) and 12 months (n=10). Each animal underwent an anterior transperitoneal surgical approach to the lumbar spine, with intervertebral reconstructions performed at L3-L4 and L5-L6 using the following techniques: (1) tricortical iliac autograft and (2) AcroFlex lumbar disc. The two treatments were equally randomized between the non-contiguous operative lumbar levels. Post-mortem analysis included histopathologic assessment of the systemic reticuloendothelial tissues, multi-directional flexibility testing of the operative functional spinal units and quantitative histological analysis of trabecular bone coverage at the prosthesis endplates. Data were statistically compared using a one-way ANOVA with the Student-Newman-Keuls test. All animals survived the operative procedure and post-operative interval without significant intra- or peri-operative complications. Histopathologic analysis of the paraffin-embedded systemic reticuloendothelial tissues indicated no significant pathologic changes at the 6- or 12-month intervals. Plain film radiographic analysis showed no lucencies or loosening of any prosthetic vertebral endplate. Biomechanical testing of the 6-month autograft, reconstructions with AcroFlex lumbar disc and non-operative control (n=10) intact motion segments indicated no significant differences in peak range of motion (ROM) in axial compression. However, axial rotation produced significantly lower ROM for the autograft treatment compared to the intact and AcroFlex groups (P<0.05). The most significant differences in peak ROM were noted between all treatment groups under flexion/extension and lateral bending loading modalities (P<0.05). By 12 months, the intact condition indicated significantly more motion in all bending modes compared to the AcroFlex and autograft treatments, which were not statistically different from each other (P>0.05). Gross histopathologic analysis of the AcroFlex disc prosthesis demonstrated excellent ingrowth at the level of the implant-bone interface, without evidence of fibrous tissue or synovium. BioQuant histomorphometric analysis at the metal-bone interface (bone contact area/total endplate area) indicated the mean ingrowth was 54.59±13.24% at 6 months and 56.79±5.85% at 12 months. Radiographic analysis showed no lucencies or loosening of the AcroFlex vertebral endplate. Based on multi-directional flexibility testing, motion was preserved in axial rotation, but significantly diminished in the other bending modalities, particularly at the 12-month interval. This effect may be secondary to the limited surface area of device-vertebral endplate contact. Histomorphometric analysis of porous ingrowth coverage at the vertebral bone-metal interface was more favorable for total disc arthroplasty compared to historical reports of cementless femoral components. This project serves as the first comprehensive in vivo investigation into the AcroFlex disc prosthesis, and establishes an excellent research model in the evaluation of total disc replacement arthroplasty.
doi:10.1007/s00586-002-0481-z
PMCID: PMC3611574  PMID: 12384732
Total disc replacement arthroplasty Animal model Biomechanics Histomorphometry Porous ingrowth
21.  Effect of cleaning and sterilization on titanium implant surface properties and cellular response 
Acta biomaterialia  2011;8(5):1966-1975.
Titanium (Ti) has been widely used as an implant material due to the excellent biocompatibility and corrosion resistance of its oxide surface. Biomaterials must be sterile before implantation, but the effects of sterilization on their surface properties have been less well studied. The effects of cleaning and sterilization on surface characteristics were bio-determined using contaminated and pure Ti substrata first manufactured to present two different surface structures: pretreated titanium (PT, Ra = 0.4 μm) (i.e. surfaces that were not modified by sandblasting and/or acid etching); (SLA, Ra = 3.4 μm). Previously cultured cells and associated extracellular matrix were removed from all bio-contaminated specimens by cleaning in a sonicator bath with a sequential acetone–isopropanol–ethanol–distilled water protocol. Cleaned specimens were sterilized with autoclave, gamma irradiation, oxygen plasma, or ultraviolet light. X-ray photoelectron spectroscopy (XPS), contact angle measurements, profilometry, and scanning electron microscopy were used to examine surface chemical components, hydrophilicity, roughness, and morphology, respectively. Small organic molecules present on contaminated Ti surfaces were removed with cleaning. XPS analysis confirmed that surface chemistry was altered by both cleaning and sterilization. Cleaning and sterilization affected hydrophobicity and roughness. These modified surface properties affected osteogenic differentiation of human MG63 osteoblast-like cells. Specifically, autoclaved SLA surfaces lost the characteristic increase in osteoblast differentiation seen on starting SLA surfaces, which was correlated with altered surface wettability and roughness. These data indicated that recleaned and resterilized Ti implant surfaces cannot be considered the same as the first surfaces in terms of surface properties and cell responses. Therefore, the reuse of Ti implants after resterilization may not result in the same tissue responses as found with never-before-implanted specimens.
doi:10.1016/j.actbio.2011.11.026
PMCID: PMC3618465  PMID: 22154860
Titanium; Sterilization; Roughness; Hydrophilicity; MG63 cells
22.  Twenty-year Followup of an Uncemented Stem in Primary THA 
Background
Uncemented stems have been used in THA for well over two decades, but there are relatively few studies reporting on the results after 20 years.
Questions/purposes
The purpose of this study was to evaluate at a minimum followup of 20 years (1) hip scores; (2) radiographic findings, including stem fixation and osteolysis; (3) reoperations; and (4) survivorship free from aseptic loosening in a group of patients who underwent primary THA using a proximally porous-coated, plasma-sprayed, straight-stemmed, titanium-alloy femoral component.
Methods
Between 1987 and 1993, we performed 1517 primary THAs, of which 447 were cementless, and 157 used the implant under study here (representing 10% of the THAs during the period in question). General indications for the use of the study stem included (1) younger age with relatively stronger bone (average age 55 years in this study); (2) patients not involved in another study protocol (as were the 278 other cementless hips implanted during this time); and (3) patients who, at the surgeon’s discretion, would be compliant with protected weightbearing. Of those, 111 were available for followup at a minimum of 20 years (mean, 20 years), whereas 36 had died and nine (6%) were lost to followup or declined participation. The primary diagnosis was osteoarthritis in 77 hips (69%). The mean age at operation was 55 years. The clinical result was evaluated on the basis of the Harris hip score. Radiographic analysis was performed at each followup visit for distal cortical hypertrophy, spot welds, radiolucencies, stem subsidence, varus or valgus shift, osteolysis, and femoral component loosening. Kaplan-Meier analysis was performed to evaluate the survival of the femoral component.
Results
The mean Harris hip score improved from 46 points to 87 points (of a possible 100 points) at the most recent followup. All hips had evidence of proximal femoral remodeling consistent with osseous ingrowth. Femoral osteolyis was seen in 22 hips (20%). One stem was revised as a result of a periprosthetic fracture. No femoral component had evidence of loosening, and none was revised. Thirty-three acetabular components (30%) were revised.
Conclusions
This femoral component provided durable long-term fixation for over two decades after THA. The porous stem geometry is still in use today and will continue to be studied into the third decade of use.
Level of Evidence
Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
doi:10.1007/s11999-014-3763-y
PMCID: PMC4294900  PMID: 24993142
23.  Greater osteoblast and endothelial cell adhesion on nanostructured polyethylene and titanium 
Mostly due to desirable mechanical properties (such as high durability and low wear), certain synthetic polymers (such as polyethylene) and metals (such as titanium) have found numerous applications in the medical device arena from orthopedics to the vasculature, yet frequently, they do not proactively encourage desirable cell responses. In an effort to improve the efficacy of such traditional materials for various implant applications, this study used electron beam evaporation to create nanostructured surface features that mimic those of natural tissue on polyethylene and titanium. For other materials, it has been shown that the creation of nanorough surfaces increases surface energy leading to greater select protein (such as vitronectin and fibronectin) interactions to increase specific cell adhesion. Here, osteoblast (bone forming cells) and endothelial cell (cells that line the vasculature) adhesion was determined on nanostructured compared to conventional, nano-smooth polyethylene and titanium. Results demonstrated that nanorough surfaces created by electron beam evaporation increased the adhesion of both cells markedly better than conventional smooth surfaces. In summary, this study provided evidence that electron beam evaporation can modify implant surfaces (specifically, polyethylene and titanium) to have nanostructured surface features to improve osteoblast and endothelial cell adhesion. Since the adhesion of anchorage dependent cells (such as osteoblasts and endothelial cells) is a prerequisite for their long-term functions, this study suggests that electron beam evaporation should be further studied for improving materials for various biomedical applications.
doi:10.2147/IJN.S13047
PMCID: PMC2939710  PMID: 20856840
nanotechnology; polyethylene; osteoblasts; orthopedics; vascular; titanium
24.  Bone Response to Surface-Modified Titanium Implants: Studies on the Early Tissue Response to Implants with Different Surface Characteristics 
In a series of experimental studies, the bone formation around systematically modified titanium implants is analyzed. In the present study, three different surface modifications were prepared and evaluated. Glow-discharge cleaning and oxidizing resulted in a highly stoichiometric TiO2 surface, while a glow-discharge treatment in nitrogen gas resulted in implants with essentially a surface of titanium nitride, covered with a very thin titanium oxide. Finally, hydrogen peroxide treatment of implants resulted in an almost stoichiometric TiO2, rich in hydroxyl groups on the surface. Machined commercially pure titanium implants served as controls. Scanning Auger Electron Spectroscopy, Scanning Electron Microscopy, and Atomic Force Microscopy revealed no significant differences in oxide thickness or surface roughness parameters, but differences in the surface chemical composition and apparent topography were observed. After surface preparation, the implants were inserted in cortical bone of rabbits and evaluated after 1, 3, and 6 weeks. Light microscopic evaluation of the tissue response showed that all implants were in contact with bone and had a large proportion of newly formed bone within the threads after 6 weeks. There were no morphological differences between the four groups. Our study shows that a high degree of bone contact and bone formation can be achieved with titanium implants of different surface composition and topography.
doi:10.1155/2013/412482
PMCID: PMC3794548  PMID: 24174936
25.  Development and Applications of Porous Tantalum Trabecular Metal Enhanced Titanium Dental Implants 
Statement of Problem
Porous tantalum trabecular metal has recently been incorporated in titanium dental implants as a new form of implant surface enhancement. However, there is little information on the applications of this material in implant dentistry.
Methods
We, therefore review the current literature on the basic science and clinical uses of this material.
Results
Porous tantalum metal is used to improve the contact between osseous structure and dental implants; and therefore presumably facilitate osseointegration. Success of porous tantalum metal in orthopedic implants led to the incorporation of porous tantalum metal in the design of root-from endosseous titanium implants. The porous tantalum three-dimensional enhancement of titanium dental implant surface allows for combining bone ongrowth together with bone ingrowth, or osseoincorporation. While little is known about the biological aspect of the porous tantalum in the oral cavity, there seems to be several possible advantages of this implant design. This article reviews the biological aspects of porous tantalum enhanced titanium dental implants, in particular the effects of anatomical consideration and oral environment to implant designs.
Conclusions
We propose here possible clinical situations and applications for this type of dental implant. Advantages and disadvantages of the implants as well as needed future clinical studies are discussed.
doi:10.1111/cid.12059
PMCID: PMC3708989  PMID: 23527899

Results 1-25 (1411694)