Whole-body low-dose computed tomography in multiple myeloma staging: Superior diagnostic performance in the detection of bone lesions, vertebral compression fractures, rib fractures and extraskeletal findings compared to radiography with similar radiation exposure

Abstract

The primary objective of the present prospective study was to compare the diagnostic performance of conventional radiography (CR) and whole-body low-dose computed tomography (WBLDCT) with a comparable radiation dose reconstructed using hybrid iterative reconstruction technique, in terms of the detection of bone lesions, skeletal fractures, vertebral compressions and extraskeletal findings. The secondary objective was to evaluate lesion attenuation in relation to its size. A total of 74 patients underwent same-day skeletal survey by CR and WBLDCT. In CR and WBLDCT, two readers assessed the number of osteolytic lesions at each region and stage according to the International Myeloma Working Group (IMWG) criteria. A single reader additionally assessed extraskeletal findings and their significance, the number of vertebral compressions and bone fractures. The radiation exposure was 2.7±0.9 mSv for WBLDCT and 2.5±0.9 mSv for CR (P=0.054). CR detected bone involvement in 127 out of 486 regions (26%; P<0.0001), confirmed by WBLDCT. CR underestimated the disease stage in 16% and overestimated it in 8% of the patients (P=0.0077). WBLDCT detected more rib fractures compared with CR (188 vs. 47; P<0.0001), vertebral compressions (93 vs. 67; P=0.010) and extraskeletal findings (194 vs. 52; P<0.0001). There was no correlation observed between lesion size (≥5 mm) and its attenuation (r=−0.006; P=0.93). The inter-observer agreement for the presence of osteolytic lesions was κ=0.76 for WBLDCT, and κ=0.55 for CR. The present study concluded that WBLDCT with hybrid iterative reconstruction technique demonstrates superiority to CR with an identical radiation dose in the detection of bone lesions, skeletal fractures, vertebral compressions and extraskeletal findings, which results in up- or downstaging in 24% patients according to the IMWG criteria. The attenuation of osteolytic lesions can be measured with the avoidance of the partial volume effect.

Keywords: plasma cell disorder, staging, osteolytic lesion, computed tomography, x-ray

Introduction

Clonal plasma cell disorders comprise a set of hematological conditions with substantial differences not only in laboratory parameters, such as hypercalcemia, renal insufficiency and anemia, bone marrow findings, including infiltration by clonal plasma cells, and patient complaints and prognosis, but also in the therapeutic approach (1,2). Imaging has an integral role in the decision making process of whether to initiate treatment (3). The presence and number of osteolytic lesions detected by radiographic skeletal survey was one of the key criteria in the original 1975 Durie-Salmon staging system (4), which was later revised in the context of expanding cross-sectional imaging (5). Currently, the evaluation of skeletal findings is based on the International Myeloma Working Group (IMWG) criteria for monoclonal gammopathies and multiple myeloma, which distinguishes between the presence or absence of structural changes, regardless of their quantity (3,6).

The superiority of cross-sectional imaging methods including whole body computed tomography (CT), magnetic resonance imaging (MRI) or positron emission tomography (PET) in detecting osteolytic lesions (resulting in up- or downstaging of disease) in individual patients has previously been established in several studies (69). However, knowledge remains limited concerning quantitative comparison of region-based detection mismatch between conventional radiography (CR) and whole-body low-dose CT (WBLDCT), with similar radiation exposure using hybrid iterative reconstruction technique, inter-observer agreement, as well as the evaluation of skeletal fractures, vertebral compressions and extraskeletal pathology, and the utility of lesion characterization by its attenuation.

The primary objective of the present study was to compare skeletal survey by the means of CR and WBLDCT, with similar radiation exposure reconstructed with hybrid iterative reconstruction technique in terms of the number of involved regions, region-based mismatch, staging, skeletal fractures and vertebral compressions, as well as extraskeletal findings. The secondary objective of the present study was to evaluate image quality and lesion attenuation in relation to its size to establish whether a reliable measurement of its attenuation can be performed.

Materials and methods

Patient information

The present prospective study was performed in accordance with the Declaration of Helsinki and was approved by the Ethics Committee of the General University Hospital (Prague, Czech Republic). All patients signed informed consent. A total of 74 patients underwent skeletal survey using CR and WBLDCT on the same day, between May 2013 and May 2015. The mean age of the patients was 65.1±10.7 years, 53% were males and their body mass index was 26.5±3.5 kg/m2. Patients had the following types of myeloma (2,3): Immunoglobulin (IgG) κ, 43%; IgG λ, 22%; IgA λ, 12%; IgA κ, 7%; serum free light chains (sFLC) κ, 7%; sFLC λ, 4%; IgG κ+λ, 1%; cFLC λ, 1%; non-secretory, 1%; and IgM, 1%. A total of 54, 15 and 31% of patients were classified as International Staging System stage I, II and III, respectively (10). In total, 50% of the patients had been previously treated by chemotherapy and/or stem cell transplant.

CR

Radiographs were acquired on a clinical computed radiography system (Multix Pro; Siemens AG, Munich, Germany) with standard settings for each of the following 19 projections: Skull [anteroposterior (AP), lateral (LL)], cervical, thoracic and lumbar spine (AP, LL), chest [posterioanterior (PA)], ribs (AP), pelvis (AP), thigh (AP), leg (AP), arm (AP) and forearm (AP). The images were reviewed on a clinical workstation (Fujitsu-Siemens Esprimo P5925; Siemens AG) with medical grade display (NEC MD213MG; NEC Display Solutions Europe GmbH, Munich, Germany) and clinical viewer (Syngo Imaging XS, version VA70B; Siemens AG).

WBLDCT

Unenhanced WBLDCT scans were performed on a 256-slice scanner (Brilliance iCT 256; Philips Healthcare, Best, The Netherlands) with the following parameters: Peak tube voltage, 120 kV; planned tube time-current product, 30 mAs; detector collimation, 128×0.625 mm; rotation time, 0.5 sec; pitch, 0.993; matrix size, 512×512; reconstructed in 0.9 mm sections using filter C (medium sharp reconstruction kernel) and hybrid iterative reconstruction technique (iDose4) set on level 4 (of 6). The scans were reviewed on a multimodality client workstation (Intellispace Portal v4.0.4; Philips Healthcare) by two independent readers experienced in reading skeletal radiographs and CT (10 and 20 years' experience, respectively).

Assessment of CR and WBLDCT results

In CR and WBLDCT, the readers reported the number of osteolytic lesions in every region (1 to 5; or >5) and stage according to the current IMWG criteria (3). The first reader also assessed extraskeletal findings and their clinical importance (unimportant; likely unimportant; potentially important finding) and the number of vertebral compressions and skeletal fractures (11). The first reader additionally measured the size of the largest lesion in every region and, in lesions ≥5 mm, their attenuation (3). The quality of WBLDCT examination was rated on a four-point Likert scale (0, excellent; 1, standard; 2, suboptimal; 3, insufficient) (12).

Calculation of the radiation dose

In ten randomly chosen patients, the radiation dose from radiography was calculated using PCXMC version 2.0 (STUK, Helsinki, Finland), and from WBLDCT using ImPACT CT Patient Dosimetry Calculator 1.0.4 (ImPACT, London, UK). In the remaining patients, a calculated weighting factor of 0.093 mSv.mGy−1.cm−1 was used to estimate the radiation dose from WBLDCT using the dose length product (DLP) (13).

Statistical analysis

Statistical tests were performed using MedCalc, version 12 (MedCalc Software, Ostend, Belgium). To test for statistical significance, the Wilcoxon signed rank test or pairwise t-tests were used for comparison between WBLDCT and CR. Correlation between the attenuation and size of osteolytic lesions was expressed as Cohen's κ. P<0.05 was considered to indicate a statistically significant difference.

Results

CR detected bone involvement in 127 out of 486 regions (26%; P<0.0001), confirmed by WBLDCT. CR underestimated disease stage according to the IMWG criteria in 16% and overestimated it in 8% of the patients (P=0.0077; Fig. 1A). Region-based comparison between CR and WBLDCT is shown in Figs. 2 and and3.3. The inter-observer agreement for the presence of osteolytic lesions was κ=0.76 [95% confidence interval (CI), 0.72–0.80] for WBLDCT, and κ=0.55 (95% CI, 0.50–0.62) for CR (Fig. 4). WBLDCT detected more vertebral compressions (93 vs. 67; P=0.010), rib fractures (188 vs. 47; P<0.0001) and skeletal fractures elsewhere (15 vs. 7; P=0.006; Fig. 1B) compared with CR. The mean size of the lesions missed by CR was 9.3 mm [interquartile range (IQR) 4.3–17.2 mm], compared with the mean size of lesions detected by CR, which was 12.2 mm (IQR 4.5–22.2 mm) (P=0.29; Fig. 1C). There was no correlation between size of the lesions (14.5 mm; IQR, 8.4-23 mm) and their attenuation (18.5 Hounsfield units; IQR, −13-49; Spearman's r=−0.006; P=0.93).

Figure 1.
(A) Compared to WBLDCT, CR underestimated the disease stage in 16% and overestimated it in 8% of the patients. (B) WBLDCT detected more vertebral compressions overall (93 vs. 67; P=0.010), rib fractures (188 vs. 47; P<0.0001) and skeletal fractures ...
Figure 2.
Comparison of the number of regions involved by osteolytic bone lesions between CR and WBLDCT (74 patients). CR, conventional radiography; WBLDCT, whole-body low-dose computed tomography; C spine, cervical spine; T spine, thoracic spine; L spine, lumbar ...
Figure 3.
Sensitivity and specificity of CR in the detection of osteolytic bone lesions compared to WBLDCT, grouped by regions. CR, conventional radiography; WBLDCT, whole-body low-dose computed tomography; C spine, cervical spine; T spine, thoracic spine; L spine, ...
Figure 4.
Inter-observer agreement in the detection of osteolytic bone lesions in each region expressed as kappa (κ) ranged from moderate to almost perfect in WBLDCT and from no agreement to almost perfect agreement in CR. In general, the inter-observer ...

In total, there were 52 secondary findings detected on CR, 60% of them as a result of previous surgery or interventional procedure. None of these were deemed clinically significant. CT showed 194 extraskeletal findings (P<0.0001); 16% of them were procedure-associated and an additional 16% were evaluated as being clinically significant or requiring further investigation. They included the presence of a soft tissue mass, lymphadenopathy, aneurysm of abdominal aorta, pneumonia, ascites, non-cystic liver lesions, pulmonary mass or nodule (>10 mm), splenomegaly, hepatomegaly, complicated renal cyst and hemopericardium.

The mean DLP was 289±85 mGy·cm−1 resulting in a radiation dose estimate of 2.7±0.9 mSv on CT. The radiation dose estimate from radiographic examinations was 2.5±0.9 mSv (P=0.054). The score for WBLDCT image quality rated on 4-point Likert scale was 1.1±0.3.

Discussion

Skeletal survey by CR is a basic method for the detection of lytic lesions in the staging of clonal plasma cell disorders (4), which has been observed to be outperformed by CT, MRI and PET-CT (3).

Several varying protocols for whole body CT in the staging of multiple myeloma have been reported. Standard or low-dose protocols with either 120 or 100 kV peak tube voltage and 40–100 mAs planned tube time-current have been used without iterative reconstruction technique, with a resulting radiation exposure between 4 and 10 mSv (7,14). Gleeson et al (15) utilized a 140 kV protocol with 14 mAs or 25 mAs, and an average radiation exposure of 3.3 mSv, which resulted in adequate image quality in 82% of patients. Although 140 kV peak tube voltage results in improved penetration of the x-rays compared to 120 kV, it also decreases contrast between bone calcium and soft tissue and increases the radiation exposure (16). As recent advances in iterative reconstruction technique offer significant improvements in image quality and a reduction of image noise and artifacts compared to standard filtered projection, the radiation dose may be decreased even further without sacrificing the image quality, as proposed in the present study.

For the radiation dose and resulting image quality, positioning of the patient has an important role (17). If the torso is scanned with arms placed alongside the body, a 30% greater radiation dose is required to compensate for the attenuation caused by the arms. Fortunately certain artifacts, including beam hardening and ring artifacts (most prominent in the lumbar spine), may be mitigated by positioning the arms more anteriorly (17). This results in the shifting of the ‘ring’ artifacts in the same direction, thus improving the image quality of the spine. Furthermore, the present study observed that these artifacts are less appreciated if the spine is viewed in the coronal rather than the sagittal plane, as is commonly done (Fig. 5).

Figure 5.
Comparison of conspicuity of a 18 mm osteolytic lesion in the second lumbar vertebra (L2) between WBLDCT images in the (A) sagittal plane and (B) coronal plane and conventional radiography in the (C) lateral view and (D) anterior-posterior view. Even ...

The present study confirmed that compared to WBLDCT, CR is able to identify less than one-third of regions involved by osteolytic lesions (9,17). Additionally, the present study demonstrated that the poorest diagnostic performance of CR could be expected in the spine and rib cage. Large bony destruction of a vertebral body must occur before it becomes detectable by CR, by which time the vertebral body would have mostly collapsed (Fig. 5). Changes in bone structure due to porosis or degenerative disease are better distinguished from osteolytic lesions on CT, even though demineralization decreases perceived image quality on low dose scans (15).

In terms of the therapeutic impact, rather than the precise number of lesions or the affected regions, it is more important to quantify the change of the stage (6). As the majority of patients undergoing skeletal survey exhibit multiple lesions, the lack of sensitivity of CR, particularly in the spine, is mitigated by imaging of other involved regions, particularly the appendicular skeleton, calvaria and pelvis.

The present study demonstrated that there was no correlation between the lesion size and its attenuation, indicating that its attenuation can be measured with the avoidance of partial volume effect. This is a significant finding because myeloma lesions change their attenuation with treatment (18). Similar changes that occur in the bone marrow of the long bones may also be detected not only by MRI, but also by CT (19,20). Further study is warranted to research whether this feature may be used to select patients who have entered remission.

Secondary findings (unrelated to the indication of the examination) are an integral part of imaging. The present study confirmed that CR grossly underestimates extraskeletal findings, including those requiring further investigation or treatment.

The present study has several limitations. Firstly, a single CT scanner was used, but it was considered that solutions by other major vendors with hybrid or model based iterative reconstruction technology would be comparable. Furthermore, the radiation dose from CR examination varies considerably, even within a single institution. In addition, due to ethical considerations, the present study did not include healthy controls and there were only 20% of patients without osteolytic lesions. Finally, the study group was inhomogeneous, and half of the patients had previously undergone treatment.

In conclusion, WBLDCT skeletal survey with hybrid iterative reconstruction technique demonstrates superiority to CR with a comparable radiation dose in the detection of bone lesions, skeletal fractures, vertebral compressions and extraskeletal findings, which results in up- or downstaging in 24% of the patients, according to the IMWG criteria. CR has poorer performance in the detection of osteolytic lesions, particularly in the spine and rib cage. The attenuation of osteolytic lesions may be measured with avoidance of the partial volume effect, but additional study is required to demonstrate whether its changes could be used as an auxiliary biomarker of therapeutic response.

Acknowledgements

The present study was supported by the First Faculty of Medicine of Charles University (Prague, Czech Republic; grant no., PRVOUK-P27/LF1/1) and by the Ministry of Health of the Czech Republic (Prague, Czech Republic; grant no. RVO VFN 64 165).

References

1. Bird JM, Owen RG, D'Sa S, Snowden JA, Pratt G, Ashcroft J, Yong K, Cook G, Feyler S, Davies F, et al. Guidelines for the diagnosis and management of multiple myeloma 2011. Br J Haematol. 2011;154:32–75. doi: 10.1111/j.1365-2141.2011.08573.x. [PubMed] [Cross Ref]
2. Rajkumar SV. Myeloma today: Disease definitions and treatment advances. Am J Hematol. 2016;91:90–100. doi: 10.1002/ajh.24392. [PMC free article] [PubMed] [Cross Ref]
3. Rajkumar SV, Dimopoulos MA, Palumbo A, Blade J, Merlini G, Mateos MV, Kumar S, Hillengass J, Kastritis E, Richardson P, et al. International Myeloma Working Group updated criteria for the diagnosis of multiple myeloma. Lancet Oncol. 2014;15:e538–e548. doi: 10.1016/S1470-2045(14)70442-5. [PubMed] [Cross Ref]
4. Durie BG, Salmon SE. A clinical staging system for multiple myeloma. Correlation of measured myeloma cell mass with presenting clinical features, response to treatment, and survival. Cancer. 1975;36:842–854. doi: 10.1002/1097-0142(197509)36:3<842::AID-CNCR2820360303>3.0.CO;2-U. [PubMed] [Cross Ref]
5. Durie BG, Kyle RA, Belch A, Bensinger W, Blade J, Boccadoro M, Child JA, Comenzo R, Djulbegovic B, Fantl D, et al. Myeloma management guidelines: A consensus report from the Scientific Advisors of the International Myeloma Foundation. Hematol J. 2003;4:379–398. doi: 10.1038/sj.thj.6200312. [PubMed] [Cross Ref]
6. Dimopoulos M, Terpos E, Comenzo RL, Tosi P, Beksac M, Sezer O, Siegel D, Lokhorst H, Kumar S, Rajkumar SV, et al. International myeloma working group consensus statement and guidelines regarding the current role of imaging techniques in the diagnosis and monitoring of multiple Myeloma. Leukemia. 2009;23:1545–1556. doi: 10.1038/leu.2009.89. [PubMed] [Cross Ref]
7. Kröpil P, Fenk R, Fritz L, Blondin D, Kobbe G, Mödder U, Cohnen M. Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma. Eur Radiol. 2008;18:51–58. doi: 10.1007/s00330-007-0738-3. [PubMed] [Cross Ref]
8. Horger M, Kanz L, Denecke B, Vonthein R, Pereira P, Claussen CD, Driessen C. The benefit of using whole-body, low-dose, nonenhanced, multidetector computed tomography for follow-up and therapy response monitoring in patients with multiple myeloma. Cancer. 2007;109:1617–1626. doi: 10.1002/cncr.22572. [PubMed] [Cross Ref]
9. Princewill K, Kyere S, Awan O, Mulligan M. Multiple myeloma lesion detection with whole body CT versus radiographic skeletal survey. Cancer Invest. 2013;31:206–211. doi: 10.3109/07357907.2013.764565. [PubMed] [Cross Ref]
10. Greipp PR, San Miguel J, Durie BG, Crowley JJ, Barlogie B, Bladé J, Boccadoro M, Child JA, Avet-Loiseau H, Kyle RA, et al. International staging system for multiple myeloma. J Clin Oncol. 2005;23:3412–3420. doi: 10.1200/JCO.2005.04.242. [PubMed] [Cross Ref]
11. Zalis ME, Barish MA, Choi JR, Dachman AH, Fenlon HM, Ferrucci JT, Glick SN, Laghi A, Macari M, McFarland EG, et al. CT colonography reporting and data system: A consensus proposal. Radiology. 2005;236:3–9. doi: 10.1148/radiol.2361041926. [PubMed] [Cross Ref]
12. Allen BC, Baker ME, Einstein DM, Remer EM, Herts BR, Achkar JP, Davros WJ, Novak E, Obuchowski NA. Effect of altering automatic exposure control settings and quality reference mAs on radiation dose, image quality, and diagnostic efficacy in MDCT enterography of active inflammatory Crohn's disease. Am J Roentgenol. 2010;195:89–100. doi: 10.2214/AJR.09.3611. [PubMed] [Cross Ref]
13. Huda W, Magill D, He W. CT effective dose per dose length product using ICRP 103 weighting factors. Med Phys. 2011;38:1261–1265. doi: 10.1118/1.3544350. [PubMed] [Cross Ref]
14. Horger M, Claussen CD, Bross-Bach U, Vonthein R, Trabold T, Heuschmid M, Pfannenberg C. Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: An alternative to conventional radiography. Eur J Radiol. 2005;54:289–297. doi: 10.1016/j.ejrad.2004.04.015. [PubMed] [Cross Ref]
15. Gleeson TG, Moriarty J, Shortt CP, Gleeson JP, Fitzpatrick P, Byrne B, McHugh J, O'Connell M, O'Gorman P, Eustace SJ. Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions and correlation of disease distribution with whole-body MRI (WBMRI) Skeletal Radiol. 2009;38:225–236. doi: 10.1007/s00256-008-0607-4. [PubMed] [Cross Ref]
16. Anderson NG, Butler AP, Scott NJ, Cook NJ, Butzer JS, Schleich N, Firsching M, Grasset R, de Ruiter N, Campbell M, Butler PH. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE. Eur Radiol. 2010;20:2126–2134. doi: 10.1007/s00330-010-1768-9. [PubMed] [Cross Ref]
17. Downey K, Castellano E, Mears D, Kaiser M, Messiou C. Low-dose whole-body CT for staging multiple myeloma. Clin Radiol. 2015;70(Suppl 1):S7. doi: 10.1016/j.crad.2015.06.028. [Cross Ref]
18. Schulze M, Weisel K, Grandjean C, Oehrlein K, Zago M, Spira D, Horger M. Increasing bone sclerosis during bortezomib therapy in multiple myeloma patients: Results of a reduced-dose whole-body MDCT study. AJR Am J Roentgenol. 2014;202:170–179. doi: 10.2214/AJR.12.10367. [PubMed] [Cross Ref]
19. Martínez-Martínez F, Kybic J, Lambert L, Mecková Z. Fully automated classification of bone marrow infiltration in low-dose CT of patients with multiple myeloma based on probabilistic density model and supervised learning. Comput Biol Med. 2016;71:57–66. doi: 10.1016/j.compbiomed.2016.02.001. [PubMed] [Cross Ref]
20. Nishida Y, Matsue Y, Suehara Y, Fukumoto K, Fujisawa M, Takeuchi M, Ouchi E, Matsue K. Clinical and prognostic significance of bone marrow abnormalities in the appendicular skeleton detected by low-dose whole-body multidetector computed tomography in patients with multiple myeloma. Blood Cancer J. 2015;5:e329. doi: 10.1038/bcj.2015.57. [PMC free article] [PubMed] [Cross Ref]

Articles from Oncology Letters are provided here courtesy of Spandidos Publications