PMCCPMCCPMCC

Search tips
Search criteria 

Advanced

 
Logo of nihpaAbout Author manuscriptsSubmit a manuscriptHHS Public Access; Author Manuscript; Accepted for publication in peer reviewed journal;
 
J Neurosci. Author manuscript; available in PMC 2013 April 10.
Published in final edited form as:
PMCID: PMC3502008
NIHMSID: NIHMS414431

Stochastic Facilitation of Artificial Tactile Sensation in Primates

Abstract

Artificial sensation via electrical or optical stimulation of brain sensory areas offers a promising treatment for sensory deficits. For a brain-machine-brain interface (BMBI), such artificial sensation conveys feedback signals from a sensorized prosthetic limb. The ways neural tissue can be stimulated to evoke artificial sensation and the parameter space of such stimulation, however, remain largely unexplored. Here we investigated whether stochastic facilitation (SF) could enhance an artificial tactile sensation produced by intracortical microstimulation (ICMS). Two rhesus monkeys learned to use a virtual hand, which they moved with a joystick, to explore virtual objects on a computer screen. They sought an object associated with a particular artificial texture (AT) signaled by a periodic ICMS pattern delivered to the primary somatosensory cortex (S1) through a pair of implanted electrodes. During each behavioral trial, aperiodic ICMS (i.e., noise) of randomly chosen amplitude was delivered to S1 through another electrode pair implanted 1 mm away from the site of AT delivery. Whereas high-amplitude noise worsened AT detection, moderate noise clearly improved the detection of weak signals, significantly raising the proportion of correct trials. These findings suggest that SF could be utilized to enhance prosthetic sensation.

Introduction

Perhaps somewhat counter-intuitive, combining informative signals with noise can enhance signal processing in biological systems (Moss et al., 2004). This phenomenon is referred to as SF or stochastic resonance (McDonnell and Ward, 2011). SF occurs when moderate levels of noise increase the number of neural threshold crossings, but also keep those crossings in synchrony with the signal (Moss et al., 2004). More intense noise masks the signal and worsens its detection. Examples of SF in human sensory processing include improved detection of visual stimuli (Kitajo et al., 2003), as well as mechanical stimuli applied to the fingers (Collins et al., 1996) and the foot sole (Wells et al., 2005). Similarly, SF has been reported for the cercal sensory system of crickets (Levin and Miller, 1996); CA1 neurons in hippocampal slices from rats (Stacey and Durand, 2001); and the spinal circuits of the cat (Martínez et al., 2007). However, there is an ongoing debate as to whether SF serves any positive function in the neural circuitry (McDonnell and Abbott, 2009; McDonnell and Ward, 2011). Additionally, it is unclear whether SF could be utilized in assistive devices for people with sensory disabilities, for example systems for sensory substitution (Bach-y-Rita and Kercel, 2003) and neural prosthetics with artificial sensation (Romo et al., 1998; O’Doherty et al., 2011).

Recently we described a sensorized neural prosthetic, called BMBI, where neuronal activity recorded in the primary motor cortex (M1) was employed to control the movements of a virtual arm while artificial tactile feedback from such an actuator was generated by ICMS patterns delivered directly to S1 (O’Doherty et al., 2009; 2011; 2012). This paradigm opens the possibility of aiding future human users of neuroprosthetic limbs with sensory signals arising from a variety of limb sensors. However, in order to develop sensorized neural prostheses further, detailed exploration is needed into ICMS as the means to reproduce the exteroception and proprioception normally provided by somatic sensation. Of particular interest is an inquiry into the processing of sensations evoked by ICMS when they are mixed with noisy inputs. For natural sensation, this problem is routinely solved by biological organisms in real-life environments (Moss et al., 2004). For artificial sensation, however, the research is only starting (O’Doherty et al., 2012). In the present study, we hypothesized that SF could enhance detection of weak ICMS patterns under an active exploration paradigm (O’Doherty et al., 2011; 2012). Accordingly, we delivered mixtures of stimulus and noise to S1 in different proportions and tested how their different combinations affected the subject’s active exploration of artificial textures (ATs).

Materials & Methods

Two rhesus monkeys, M (male) and N (female), were chronically implanted with cortical stainless steel microelectrode arrays in M1 and S1 in both hemispheres (Nicolelis et al., 2003) (Fig. 1A). Neuronal activity was sampled in the arm and hand areas of M1 and S1 in the hemisphere contralateral to the working arm. We used four electrodes of the S1 implants for ICMS delivery. Stimulation was applied to the right hemisphere arm area of S1 in monkey M and the right hemisphere leg area of S1 in monkey N, using a custom built 4-channels current-controlled stimulator (Hanson et al., 2012). The monkeys were trained to move an image of the forearm and the hand (animated using MOTIONBUILDER, Autodesk) on a computer screen with a joystick (Fig. 1B). Using this virtual hand, they explored virtual objects presented on the screen, which were visually identical, yet differed in their ATs. Each trial started with the monkeys placing the virtual hand over a circular target that appeared at the center of the screen. At this time, ICMS noise of randomly chosen intensity started and continued until the end of the trial. Following the initial central hold, two visual objects appeared on the left and on the right of the screen, equidistant from the center. Then, the monkeys freely explored each of these objects to find the one associated with a periodic ICMS pattern, which we call the rewarded artificial texture (RAT). The other object lacked such ICMS feedback (null artificial texture, NAT). The RAT consisted of pulse pairs (with 10 ms inter-pulse interval for monkey M and 5 ms for monkey N) delivered at a frequency of 10 Hz. The monkey selected one of the objects by holding the virtual hand over it for 2 s, and a juice reward was given if they correctly selected the RAT object (Fig. 1C). Each ICMS pulse was a symmetric, biphasic, charge-balanced current waveform delivered through a pair of electrodes implanted at 3 mm from each other (i.e. bipolar stimulation). For noise delivery, a different electrode pair was used, implanted 1 mm away from the first pair of electrodes (Fig. 1A). The inter-pulse interval of such an aperiodic signal was drawn from a gamma distribution with the coefficient of variation (ratio of the standard deviation to the mean) equal to 1 (O’Doherty et al., 2012).

Figure 1
Experimental setup and task schematics. A, Arrays of microelectrodes were implanted in S1 and M1. Stimulating electrodes for monkey M (inset) are highlighted in red (artificial texture, AT) and yellow (noise). B, Monkeys manipulated a joystick to move ...

All animal procedures were performed in accordance with the National Research Council’s Guide for the Care and Use of Laboratory Animals and were approved by the Duke University Institutional Animal Care and Use Committee.

Results

Monkeys M and N were previously overtrained in a similar active exploration task (O’Doherty et al., 2011), so it took them just 1 and 3 training sessions, respectively, to achieve around 90% accuracy in the two-target task of this study. No noise was presented at that point. We then measured the psychometric threshold for RAT detection in the absence of noise for each monkey. Current amplitudes in the range 5 – 150 μA were tested. The detection threshold (Gescheider, 1997) was evaluated as the current level at which the proportion of correct responses was 0.75. The psychometric curve (Fig. 3C) for monkey M was slightly shifted to the left compared to that of monkey N and therefore its threshold was lower (31 vs 45 μA for monkeys M and N, respectively).

Figure 3
Stochastic facilitation via ICMS. Fraction of trials correct per session in terms of the noise amplitude level for monkey M (diamonds, blue) and N (squares, red), for A, supra-threshold, and B, sub-threshold RAT. *, significantly different from average ...

In subsequent sessions, ICMS noise was presented throughout each trial. Noise amplitude for each trial was randomly selected in multiples of 15 μA, up to 120 μA. Data with noise were collected for 8 and 9 daily sessions for monkeys M and N, respectively (monkey M: 370 ± 60; monkey N: 418 ± 87 trials per session). For these sessions, the RAT amplitude was either supra- (50 μA) or sub-threshold (20 μA). Representative trials for a sub-threshold stimulus combined with different noise intensities are shown in Fig. 2. In these examples, the monkey correctly detected the sub-threshold RAT (20 μA) in the presence of an optimal noise (30 μA) (Fig. 2B), while failing to do so when the noise amplitude was too low (15 μA) (Fig. 2A) or too high (90 μA) (Fig. 2C). Fig. 2 also depicts the neuronal ensemble activity recorded in M1. The firing rates of M1 neurons were clearly modulated in association with the arm movements and reflected movement speed and direction.

Figure 2
Detection of signal in noise and M1 modulations. Example traces of horizontal movement of the virtual hand for three trials with different noise levels: A, low; B, optimal, and C, high. The colored horizontal bars represent the position of the targets ...

Fig. 3A shows the fraction of correct detection (averaged by session) as a function of noise amplitude for supra-threshold RATs (50 μA). Note that in the absence of noise, monkey M performed better (89.8% correct) than monkey N (77.9% correct), which is consistent with a more rapid saturation of the psychometric curve for monkey M (Fig. 3C). For monkey M, the performance decayed from this high level after noise amplitude exceeded 30 μA (significantly lower success rate as compared to the average for each noise level above 30 μA, P < 0.05, randomization test (Edgington and Onghena, 2007)). It is possible that we only observed decay simply because the performance was close to saturation from the start and could not improve in principle. However, for monkey N, whose performance level had room for improvement, we observed a similar effect: the performance was resistant to weak noise and started to deteriorate when noise amplitude exceeded 120 μA (P<0.001, randomization test).

Changes in the monkey’s detection performance with noise addition were very different when sub-threshold RATs (20 μA) were employed. This dependency was characterized by a non-monotonic curve with peaks at noise amplitude of 60 and 45 μA for monkeys M and N, respectively. Thus, for monkey M, elevated performance of approximately 0.7 was observed for three noise amplitudes: 30, 45 and 60 μA (P<0.05 for all points, randomization test). For monkey N, the curve had a single peak of 0.76 at 45 μA (P < 0.01, randomization test). Therefore, in both monkeys the addition of a moderate level of ICMS noise to a weak AT stimulus improved the animal’s detection performance. Furthermore, neither the presence of ATs nor the addition of noise substantially affected movement-related modulations observed in M1 (Fig. 2), nor did it degrade the performance of a decoding algorithm that extracted the position of the virtual arm from the population activity of M1 neurons (unscented Kalman filter (Li et al., 2009); monkey M: 125 units, monkey N: 65 units) (Fig. 4).

Figure 4
Movement predictions from M1 activity. A, position of the avatar and off-line predictions from M1 activity for 6 consecutive trials with different noise amplitudes. Performance of the decoding algorithm measured as the correlation coefficient in terms ...

Discussion

The present findings demonstrate for the first time SF effects for an artificial tactile sensation. The ability of monkeys to detect weak ICMS signals was clearly improved by the addition of moderate levels of ICMS noise. This result is consistent with previous model and experimental demonstrations of SF in physiological systems (Moss et al., 2004). Interest in SF for neural systems has dramatically increased over the last 20 years, driven by theories claiming that noise may play an important role in normal neural processing (McDonnell and Abbott, 2009; McDonnell and Ward, 2011). Since the presence of moderate amounts of internal noise may be normal and even advantageous for neural systems, several publications proposed implementing noise and SF in artificial systems designed to restore normal functions to people with disabilities, for example in cochlear implants (Morse et al., 2007), and assistive devices for postural balance (Harry et al., 2005) and hand sensorimotor tasks (Kurita et al., 2011). Here we demonstrated the practicality of this idea for prosthetic sensation evoked by ICMS. By adding background noise, we effectively gained control over the detection threshold for an artificial tactile sensation. It has yet to be determined how SF would work in the case of prosthetic sensations evoked by spatiotemporal input patterns delivered through multielectrode implants (Fitzsimmons et al., 2007). For such multichannel systems with stimulation sites distributed over the cortical surface, the superposition of spatiotemporal noise patterns could enhance signal detection in both the temporal and spatial dimensions. Furthermore, SF patterns distributed across corticothalamic loops could be obtained in sensorized neural prosthetics that utilize thalamic stimulation as an additional channel for artificial somatic sensation (Heming et al., 2010). Although in our present study we did not manipulate the statistics of the noise channel, it would be of great interest in the future to examine a variety of noise frequency characteristics. If noise contains particular frequencies, SF may accordingly filter frequency components of the input signal. Importantly for practical neuroprosthetic systems, the potential risks of neural damage associated with ICMS may be lower for a SF-based neural prosthetic because of the lower currents injected into the neural tissue (McCreery et al., 2010). In conclusion, we suggest that the incorporation of SF effects in sensorized neural prosthetics may enhance a variety of functional capabilities.

Acknowledgments

We are grateful to Gary Lehew and Jim Meloy for engineering the experimental setup and the multielectrode arrays; Dragan Dimitrov and Laura Oliveira for conducting neural surgery; Solaiman Shokur for avatar design; Zheng Li for assistance in the decoding algorithm; Tamara Phillips for experimental support; Susan Halkiotis for administrative assistance and editing the manuscript. This work was supported by NIH DP1OD006798 and NIH RC1HD063390 to M.A.L.N. The document is solely the responsibility of the authors and does not necessarily represent the views of the Office of the Director, NIH or the National Institutes of Health.

Footnotes

Conflict of interests: none

References

  • Bach-y-Rita P, Kercel SW. Sensory substitution and the human-machine interface. Trends in Cognitive Sciences. 2003;7:541–546. [PubMed]
  • Collins JJ, Imhoff TT, Grigg P. Noise-enhanced tactile sensation. Nature. 1996;383:770. [PubMed]
  • Edgington ES, Onghena P. Randomization tests. 4. Boca Raton, FL: CRC Press; 2007.
  • Fitzsimmons NA, Drake W, Hanson TL, Lebedev MA, Nicolelis MAL. Primate reaching cued by multichannel spatiotemporal cortical microstimulation. J Neurosci. 2007;27:5593–5602. [PubMed]
  • Gescheider GA. Psychophysics: The Fundamentals. 3. Mahwah, NJ: Lawrence Erlbaum Associates; 1997.
  • Hanson TL, Omarsson B, O’Doherty JE, Peikon ID, Lebedev MA, Nicolelis MAL. High-side digitally current controlled biphasic bipolar microstimulator. IEEE Trans Neural Syst Rehabil Eng. 2012;20:331–340. [PMC free article] [PubMed]
  • Harry JD, Niemi JB, Priplata AA, Collins JJ. Balancing act [noise based sensory enhancement technology. IEEE Spectr. 2005;42:36–41.
  • Heming E, Sanden A, Kiss ZHT. Designing a somatosensory neural prosthesis: percepts evoked by different patterns of thalamic stimulation. J Neural Eng. 2010;7:064001. [PubMed]
  • Kitajo K, Nozaki D, Ward LM, Yamamoto Y. Behavioral stochastic resonance within the human brain. Phys Rev Lett. 2003:90. [PubMed]
  • Kurita Y, Shinohara M, Ueda J. Wearable sensorimotor enhancer for a fingertip based on stochastic resonance. IEEE; 2011. pp. 3790–3795.
  • Levin JE, Miller JP. Broadband neural encoding in the cricket cercal sensory system enhanced by stochastic resonance. Nature. 1996;380:165–168. [PubMed]
  • Li Z, O’Doherty JE, Hanson TL, Lebedev MA, Henriquez CS, Nicolelis MAL. Unscented Kalman Filter for Brain-Machine Interfaces. PLoS ONE. 2009;4:e6243. [PMC free article] [PubMed]
  • Martínez L, Pérez T, Mirasso CR, Manjarrez E. Stochastic resonance in the motor system: effects of noise on the monosynaptic reflex pathway of the cat spinal cord. J Neurophysiol. 2007;97:4007–4016. [PubMed]
  • McCreery D, Pikov V, Troyk PR. Neuronal loss due to prolonged controlled-current stimulation with chronically implanted microelectrodes in the cat cerebral cortex. J Neural Eng. 2010;7:036005. [PMC free article] [PubMed]
  • McDonnell MD, Abbott D. What is stochastic resonance? definitions, misconceptions, debates, and its relevance to biology. PLoS Comput Biol. 2009;5:e1000348. [PMC free article] [PubMed]
  • McDonnell MD, Ward LM. The benefits of noise in neural systems: bridging theory and experiment. Nat Rev Neurosci. 2011;12:415–426. [PubMed]
  • Morse RP, Morse PF, Nunn TB, Archer KAM, Boyle P. The effect of Gaussian noise on the threshold, dynamic range, and loudness of analogue cochlear implant stimuli. J Assoc Res Otolaryngol. 2007;8:42–53. [PMC free article] [PubMed]
  • Moss F, Ward LM, Sannita WG. Stochastic resonance and sensory information processing: a tutorial and review of application. Clin Neurophysiol. 2004;115:267–281. [PubMed]
  • Nicolelis MAL, Dimitrov DF, Carmena JM, Crist R, Lehew G, Kralik JD, Wise SP. Chronic, multisite, multielectrode recordings in macaque monkeys. Proc Natl Acad Sci USA. 2003;100:11041–11046. [PubMed]
  • O’Doherty JE, Lebedev MA, Hanson TL, Fitzsimmons NA, Nicolelis MAL. A brain-machine interface instructed by direct intracortical microstimulation. Frontiers in Integrative Neuroscience. 2009;3:1–10. [PMC free article] [PubMed]
  • O’Doherty JE, Lebedev MA, Ifft PJ, Zhuang KZ, Shokur S, Bleuler H, Nicolelis MAL. Active tactile exploration using a brain-machine-brain interface. Nature. 2011;479:228–231. [PMC free article] [PubMed]
  • O’Doherty JE, Lebedev MA, Li Z, Nicolelis MAL. Virtual active touch using randomly patterned intracortical microstimulation. IEEE Trans Neural Syst Rehabil Eng. 2012;20:85–93. [PMC free article] [PubMed]
  • Romo R, Hernández A, Zainos A, Salinas E. Somatosensory discrimination based on cortical microstimulation. Nature. 1998;392:387–390. [PubMed]
  • Stacey WC, Durand DM. Synaptic noise improves detection of subthreshold signals in hippocampal CA1 neurons. J Neurophysiol. 2001;86:1104–1112. [PubMed]
  • Wells C, Ward LM, Chua R, Inglis JT. Touch noise increases vibrotactile sensitivity in old and young. Psychological Science. 2005;16:313–320. [PubMed]