3.1 Experimental Results In Vitro
The hairs of rat were shaved and depilated prior to all procedures. The skin was kept cooled in 0.9% NaCl solution during transportation and storage to avoid dehydration in air. The hair-depilated skin of rat is firstly scanned to observe the variation of imaging contrast and the penetration depth of the combined liquid paraffin with glycerol mixed solutions. The size of sample in each test is about 8 mm * 10 mm. The distance of OCT probe and sample platform remains unchanged after applying the agent.
The optical clearing effect of agents can be revealed by the contrast variation of the internal tissue in OCT images. Intensity ratio of regions (RIR) [
35] is selected in our paper to calculate quantitatively the contrast of the internal tissue and the surface. The improvement of contrast is evaluated by calculating the ratio of RIR of OCT images with and without the agent.
RIR is defined as follows,
where
N1 and
N2 are the number of pixels in the internal and surface regions, respectively,
g(
x,
y) is the gray level in the OCT image. The larger the RIR is, the higher the relative intensity value between the internal and the surface is. Further, the larger the ratio of RIR is, the better the enhanced result is. Pixels whose gray levels in the image are larger than a certain threshold can be considered as the interface pixels between the tissue and the background. A region with a given thickness below the interface pixels is selected as the surface region. Under the surface region, a region with the same thickness is selected as the internal region.
For each sample, the three OCT images without any agent applied are collected and their RIRs are averaged as the benchmark. After applying the agent, OCT images with time elapsing are collected, and their RIRs are calculated. The maximum RIR of these images is divided by the benchmark, which is regarded as the ratio of RIR of this sample. 5 samples for each concentration are tested. The average of 5 ratios of RIR for each concentration is used to evaluate its improvement of contrast.
The average ratios of RIR of different concentrations are shown in
. The thickness of the regions is 50 µm and their width is 1 mm in calculating the RIRs. Two intervals between the internal and surface region, 300 µm and 500 µm, are used to evaluate the enhancement of image contrast at different depths. Red solid curve and blue dot curve respectively represent the average ratios of RIR at intervals of 300 µm and 500 µm. The results of liquid paraffin whose volume fractions in mixed solution increased from 0% to 70% by 10% are given. 0% concentration denotes anhydrous glycerol. 70% concentration denotes that the ratio of volume between liquid paraffin and glycerol is 7:3.
From , it can be seen that all average ratios of RIR with different concentrations are larger than 1, which means that all agents can improve the contrast. Furthermore, the optical clearing effects of the mixed solution are all better than glycerol and 40% concentration is shown the best optical clearing effect both at 300 µm and 500 µm intervals.
The variation of tissue thickness can be used to reflect the deformation degree of tissue structure qualitatively. It is difficult to measure the thickness of the tissue exactly during scanning. Therefore, we kept the distance of OCT probe and sample platform unchanged after applying the agent and recorded the height variation of the interface between the tissue and the background in OCT images, which can reflect the variation of the tissue thickness indirectly. In order to simulate the environment of the living organism and avoid dehydration in air, the sample is soaked in the physiological saline solution as Refs. [
14,
31].
A region is selected from the same lateral position in all images of each group. Axial positions of the surface point in this region are averaged. The variation of the average value in different images represents the change of the position of the surface, i.e., the change of the tissue thickness. Their typical results are shown in
. Based on the above conclusion that around 40% concentration has the best optical clearing effect, only the curves of 0% and 20% - 60% concentration are given for being clearly shown. The variation trend of 10% and 70% concentration are respectively similar to 20% and 60%, so they are not given in . 1 mm width region is used to obtain the average position of the surface. The starting time 0 is the time of applying the agent, and the time of the first scanning image for different concentrations are slightly different. The time interval between two scans is about 1 min.
From , it can be seen that tissue thickness has obvious variation during the whole scanning time for the agents whose concentrations are 20% and lower than 20%. With the increase of fractions of liquid paraffin in the mixed solution, the thickness has only slight variation within 35 min. The slopes of curves in can reflect the speed of water loss. For the agents with high concentration, the water loss of the tissue is evident in the beginning, then gradually lessens and tends to stabilization. It can be explained in the following: Under the synergistic effect of liquid paraffin, the mixed solution rapidly permeate across the stratum corneum within 5 min, it leads to the dehydration of top layers of tissue. After about 10 min, the moisturizing effect of liquid paraffin begins to display, which makes the water loss and the moisture retention approximately reach the state of equilibrium. Thereafter, the dehydration becomes unobvious. After 35 min, the tissue surface is exposed in air gradually with the agent penetrating, thus the water loss happens again.
From and , it can be concluded that adding liquid paraffin in glycerol cannot only improve optical clearing effect but also reduce water loss with time elapsing. The mixed solution within 30% - 50% concentration shows the best synthetical effect.
To find the optimal duration of optical clearing effect, 12 samples with the mixed agent of different concentrations are further scanned, respectively. For each sample, the RIRs of OCT images every five minutes are calculated, and divided by the benchmark. For each concentration, 12 groups of ratios of RIR are obtained, whose average at the same time are calculated. The results of 30% - 50% concentrations are shown in
. The intervals between the surface and the internal region in and are also 300 µm and 500 µm, respectively.
The average ratios of RIR with time elapsing at 30%, 40% and 50% are shown with blue dash curve, red solid curve and green dot curve, respectively. From these curves, it can be seen that the contrast of internal and surface region are all improved after the agents applied and the improvement of 40% concentration is the best, which coincides with that of . It reaches optimal effect after 10min after applying 40% concentration solution. To show the best and worst optical clearing effect, the maximal and minimal ratios of RIR of 40% concentration in 12 groups are given in . Those of 30% and 50% concentration are similar to those of 40% concentration, so they are not given in . From these bars, although the agents have the optical clearing effect statistically, there are one or two exclusions in 12 samples at some time points. From and , it can be also seen that the contrast at 300 µm and 500 µm intervals have the similar variation trend with time elapsing for 30%, 40% and 50%, respectively.
A group of typical OCT images obtained by applying 40% concentration solution are given in
. is the OCT image without the mixed solution. – are taken every 10 min after applying the agent. From these OCT images, it can be seen that the detected depth is improved and the internal tissue is more clearly identified than . Its contrast is indeed enhanced and more fine details of tissue structure can be distinguished with the elapsing of time. It can be further seen that the signal intensity of the internal region is gradually increased from 10 min to 20 min and turn to be stable during 20 - 40 min.
In order to indicate the variation of signals of surface and internal regions with time elapsing, intensity as a function of depth is calculated. In order to reduce the interference of surface curvature, only a 1.3 mm width region with the flat surface is selected (as shown in a yellow rectangle in ). The intensities of signal with the same axial position in this region are averaged. The averaged intensities in this region varying with depth in – are shown in
. The intensities varying with depth at an arbitrarily selected position (as shown in the yellow line in ) are given in . The red solid curve represents the signal without the agent. The green dot curve, blue dot-and-dash curve, pink solid curve and dark dot curve represent the signal after applying agent 10 min, 20 min, 30 min and 40 min, respectively.
From , it can be seen that the intensity of the surface are effectively reduced by applying the mixed solution and the intensity of the internal signal is improved simultaneously.
3.2 Experimental Results In Vivo
Different positions of human skin, such as palm, back of hand, wrist, arm, finger, and etc., are scanned in vivo by our OCT system by applying the mixed solution of 30% - 50% concentrations to evaluate the optical clearing effect, and we find the similar results of contrast enhancement.
To find the optimal duration in vivo, 8 groups of OCT images of human finger are scanned at different concentrations, respectively. As the method of , the ratios of RIRs of OCT images in vivo are calculated at 30% - 50% concentrations. The results are shown in
. The intervals between the surface and the internal region of and are 500 µm and 700 µm, respectively.
The average ratios of RIR with time elapsing at 30%, 40% and 50% are shown with blue dash curve, red solid curve and green dot curve, respectively. It can be seen from , 30% - 50% concentrations all can enhance the contrast of OCT images in vivo. Their improvement is much better than that of rat skin. Because of the possibly existed variation of scanning position as a result of human body wobbling during repetitive scans and individual difference, the fluctuation of the curves in is larger than those of in vivo. Different with the experimental results in vitro, the ratios of RIR at 30% concentration is higher than those of other two concentrations. Considering the results of and , the time that reaches the best optical clearing effect is around 10 - 30 min for 30% concentration. These differences between in vivo and in vitro need to be further investigated in future.
A group of typical OCT images before and after applying 30% liquid paraffin glycerol solution is given in
. is the OCT image without the agent. – are taken in 5 min - 30 min every 5 min after applying agent. Compared – with , it can be seen that the intensity of internal signal are obviously increased. After liquid paraffin glycerol solution is applied on the skin surface, a high osmotic pressure occurs, leads the agent to penetrate through the stratum corneum rapidly. Along with the mixed agent penetrating, refractive index mismatch in tissue is lessened, and the profile of papillary layer in dermis becomes more noticeable.
From , it can be seen that the optical clearing effect of the mixed agent maintains almost changeless in 10 - 30 min in vivo. We think the blood flowing in blood-containing layers maintains the circulation of water, so that dehydration in vivo is not obvious as in vitro.
Macroscopically speaking, optical scattering mainly occurs at the tissue interfaces whose refractive indices mismatch, so the most obvious scattering layers are thus the surface of skin and the boundary between epidermis layer and dermis layer. After OCAs are applied, the scattering light on the boundaries can be reduced effectively, thereby enhancing transmittance and decreasing diffuse reflectance. From all the experiments, we find the mixed agent can effectively reduce the signal intensity reflected from the surface and improve the intensity of internal signal.
The refractive indices of epidermis and dermis of human skin
in vivo are around 1.42 and 1.37 [
36], and that of stratum corneum which is a part of epidermis is ~1.5. In our experiment, the refractive indices of liquid paraffin and glycerol, being measured with Abbe refractometer under visible light, are 1.4691 ± 0.0003 and 1.4689 ± 0.0003, respectively. It has been proven that glycerol can reduce the gradient of refractive indices between sub-layers in tissue. Therefore, adding liquid paraffin in glycerol will not alter the refractive match effect of glycerol, and can be expected to show a similar effect as glycerol alone.
From these results, we further prove that OCAs combined hydrophilic agents with lipophilic agents can enhance optical clearing effect and improve the speed of percutaneous penetration simultaneously. The stratum corneum, as a protective layer of the skin, is a dense medium with poor penetration to foreign molecules. The speed of glycerol alone to diffuse through the stratum corneum is slow. Only lipophilic agents have the ability of membrane penetration and can be used as the carrier of drug delivery. Liquid paraffin, as a kind of lipophilic agent, can enhance the percutaneous penetration of glycerol in deep layers of tissue and take synergistically optical clearing effect with glycerol, and block the evaporation of water and compensate the water loss induced by glycerol and thus reduce the tissue deformation. In addition, glycerol, as a kind of hydrophilic agent, has better optical clearing effect for the tissue under the stratum corneum than lipophilic agents as said in [
23,
26]. Under their co-operation, the optimum optical clearing effect is obtained.