Cyclosporine Trough Concentration Monitoring in Liver Transplant Patients

Cyclosporine A (CsA) monitoring of blood or plasma concentration measurements is recognized as an important part of the care of a transplant patient receiving the drug. The quantitation of CsA in biological fluids is essential for several reasons: (1) wide variability in the amount of CsA absorbed and the clearance rate of CsA have been observed, particularly in orthotopic liver transplant (OLT) patients1; (2) low CsA concentrations in blood or plasma secondary to poor drug absorption or rapid CsA elimination can be detected and adjusted; these situations are common in OLT patients due to diversion of bile through a T-tube and due to the occasional need for anticonvulsant administration; (3) high blood or plasma concentrations of CsA can be avoided through routine monitoring programs; these high levels may occur in OLT patients secondary to time-dependent increases in CsA absorption or to clamping of the T-tube; drugs that inhibit CsA metabolism such as erythromycin2 also can complicate therapy in OLT patients; (4) blood or plasma concentration monitoring aids adjustment of CsA dosage during the transition from intravenous (IV) to oral therapy and from a high initial oral dose to a lower long-term maintenance CsA dose; and (5) patient compliance with the medication regimen can be followed by blood or plasma CsA measurement.

CsA can be measured in whole blood or in plasma and serum samples. Important differences exist among the sample matrices and have been discussed previously.3 The interpretation of assay results from the two analytical methodologies available, high-performance liquid chromatography (HPLC) and the radioimmunoassay (RIA), is particularly critical in OLT patients. This article therefore discusses the appropriate timing of a trough sample and outlines those factors that affect the RIA and HPLC results in OLT patients.

SAMPLE TIMING

The trough concentrations of CsA should be that time at which the blood or plasma concentration is lowest. A delay in the rise of CsA concentrations following oral ingestion occurs because of delayed gastric emptying, but concentrations in blood or plasma increase by 1 hour following an oral dose. In most institutions, trough levels are obtained for drug concentration determination within 1 hour prior to the drug dose.

The dosing interval may determine how critical the timing of a trough CsA concentration should be. With terminal elimination half-lives ranging from 10.7 hours in renal transplant patients4 to 20.4 hours in patients with hepatic cirrhosis,5 small differences in sample timing will have little effect on the trough concentration if CsA absorption and distribution are complete. Therefore, no clinically significant difference will occur in trough samples obtained 1 to 2 hours prior to a dose when the patient receives CsA as a once-daily dose. However, shorter dosing intervals of 8 or 12 hours may require more precise timing of trough CsA samples. CsA concentrations in blood or plasma may not peak until eight hours after an oral dose,5 and the absorption and distribution processes are frequently prolonged for up to 12 hours. The change in CsA concentrations in blood or plasma during the interval of 6 to 12 hours following an oral dose is rapid in comparison with the slow elimination half-life of the drug. Altering the timing of the trough sample by 1 to 2 hours in a patient on an 8- to 12-hour CsA dosing schedule can result in significantly different blood or plasma concentrations. For example, Fig 1 presents the blood concentrations of CsA measured by RIA and HPLC following an oral dose in a transplant patient. The CsA blood concentrations measured by HPLC at eight hours (544 ng/mL) fall rapidly to the 12-hour concentration (127 ng/mL). The blood concentrations in this same patient measured by RIA decreased from 1,512 ng/mL to only 1,244 ng/mL, resulting in a significant change in the ratio of RIA:HPLC. Imprecise sampling of blood during the CsA absorptive and distributive phases of this patient could result in differing trough concentrations and their interpretation. Because changes in gastrointestinal (GI) function, dose administered, or concurrent drug therapy influence the absorptive pattern of CsA, precise trough sampling timing in patients on 8- or 12-hour dosing schedules should improve the reproducibility and clinical utility of blood or plasma monitoring for CsA.

Fig 1
Blood cyclosporine concentrations v time in a transplant patient following an oral drug dose. Measurements are by HPLC (x) and RIA (O).

Transplant patients on multiple daily doses of CsA should have their trough blood or plasma concentration sampled at the same time each day. CsA clearance rates have a diurnal variation with a more rapid clearance rate during the nighttime hours.6 Predose trough concentrations increased 38% and 72% when evening samples were collected in comparison with morning samples in two OLT patients.6 Individual patient and transplant center sample times should be standardized so that the center can develop its own consistent guidelines for acceptable desired CsA concentrations. Differences in the sampling time and the CsA dosing interval used may account for the minor variations in the desired CsA range noted between transplant centers (see Table 1).

Table 1
Desired Trough Cyclosporine Concentrations From Major Transplant Centers

Changing the CsA dosing interval without a change in total daily CsA dose can have a major effect on blood or plasma concentrations. In a small number of renal transplant patients who received the same daily CsA dose but had their dosing interval changed from every 24 to every 12 to every 8 hours, average steady-state CsA blood concentrations increased from 497 to 800 to 1,241 ng/mL, respectively.5 Dose-dependent changes in drug absorption or elimination must be considered when interpreting trough CsA concentrations after a dose or dosing interval alteration.

RIA:HPLC CONCENTRATIONS

Concentrations obtained by RIA analysis are consistently higher than those obtained by HPLC due to the cross-reactivity of CsA metabolites with the antiserum used in the RIA kits.19, 20 The percentage of cross-reactivity of some of the metabolites tested ranges from 4% to 32%. The RIA:HPLC ratio of CsA concentrations in blood, plasma, and serum is highly variable19,21,22 and depends on the patient’s liver function, the time of blood sampling in reference to the time of drug administration, the absolute CsA concentration, and whether the patient is receiving other drugs that alter hepatic metabolizing enzyme function.

Assay results from the RIA should be used with particular caution during periods of impaired hepatic function. In the first 2 weeks following liver transplantation, during liver rejection, or in the event of a technical failure (eg, hepatic artery thrombosis), the RIA:HPLC ratio is dramatically increased.23 Table 2 presents examples of the peak RIA: HPLC ratios observed early in the postoperative course of ten liver transplant patients. The ratio of trough concentrations measured by the two assays stabilized in the RIA:HPLC ratio of 1.7 to 4.2 if hepatic function was also improving. A similar observation has been made in two OLT patients by Blyden et al,24 who also report a positive correlation between the total serum bilirubin concentration and the RIA:HPLC ratio. In an earlier report,23 we also noted that significant increases in the RIA:HPLC ratio to greater than 10 in OLT patients with rises in bilirubin were associated with rejection or a technical complication. Smaller increases in the RIA:HPLC ratio were occasionally associated with increases in liver enzymes without a change in bilirubin.

Table 2
Ratio of RIA:HPLC Trough Blood Concentrations in Ten Liver Transplant Patients

Patients with severe liver disease have the ability to metabolize CsA as evidenced by their 0.8 to 4.8 mL/min/kg clearance rate5 but have a significant impairment in their ability to excrete CsA metabolites. CsA blood concentration v time data in a patient with liver disease as analyzed by RIA and HPLC are presented in Figure 2. The RIA:HPLC ratio changes over the dosing interval studied (from 1:1 to 1:4), and the pharmacokinetic parameters calculated are different5 depending on the analytical procedure used.

Fig 2
Blood concentrations of cyclosporine v tima in a liver failure patient following a single IV drug dose. Measurements are by HPLC (●) and RIA (○).

The time of the trough blood sampling for CsA can significantly affect the RIA:HPLC ratio. In Fig 1, sampling eight hours after the oral CsA dose would have yielded an RIA:HPLC ratio of 2.8, but sampling at 12 hours following the dose would change the results and ratio to 9.8. This difference in the RIA:HPLC ratio over a dosing interval is explained by two observations. First, higher concentrations of CsA measured by HPLC result in better agreement between the RIA and HPLC assays because the parent CsA compound then comprises the majority of substance measured by RIA. At lower CsA concentrations in blood or plasma, the RIA is more likely to overestimate CsA, resulting in a higher RIA:HPLC ratio (see Fig 3). Second, the elimination half-life measured by RIA is greater than the CsA elimination half-life measured by HPLC. Therefore, the fall in CsA concentration in blood or plasma during a dosing interval measured by RIA will not parallel the decline measured by HPLC.

Fig 3
Blood concentrations measured by RIA v HPLC in a single patient over one dosing interval. The solid line represents a 1:1 HPLC:RIA ratio.

Other pharmacologic agents may affect the formation or elimination of CsA metabolites, thereby affecting the RIA:HPLC ratio. For example, previous reports25,26 have shown that CsA concentrations measured by RIA increase when methylprednisolone is administered concurrently with CsA. Our own observations in patients receiving high-dose methylprednisolone have not demonstrated any difference in CsA clearance measured by HPLC when compared with a control period.27 When patient trough concentrations were monitored by RIA and HPLC, an increase in the RIA:HPLC ratio was observed coincident with the administration of pulse doses of methylprednisolone (Fig 4). Methylprednisolone affects the metabolism of CsA by enhancing the production of metabolites that react with the RIA but that have little effect on HPLC measurements. The effect of other drugs on the RIA:HPLC ratio is unknown but should be carefully monitored when pharmacologic agents known to alter CsA blood or plasma concentrations are taken concurrently with CsA (see Table 3).

Fig 4
The ratio of RIA:HPLC blood trough concentration measurements in a transplant patient over time. Note the increase in the ratio in association with Solu-Medrol (methylprednisolone) dosing.
Table 3
Drug Interactions With Cyclosporine That Alter Blood or Plasma Measurements

The importance of alterations in the RIA:HPLC ratio will become clearer as the immunologic and toxicologic effects of CsA metabolites are defined. At present, the metabolites of CsA are considered to have little pharmacologic activity.38 If this observation is true, RIA trough CsA measurements could be misleading during periods of hepatic dysfunction or when other agents, such as methylprednisolone, alter the RIA:HPLC ratio. Trough CsA concentrations measured by RIA have been associated with both the nephrotoxicity of CsA15 and the tremors that the drug can induce.24 The RIA can provide useful trough CsA measurements on OLT patients who have stable hepatic function but should be used in conjunction with HPLC during the immediate postoperative weeks, during periods of changing hepatic function, and when other pharmacologic agents are administered that could alter the metabolism of CsA.

SUMMARY

Trough blood or plasma concentration measurements of CsA must be carefully interpreted in OLT patients in relation to hepatic function, sample timing, assay specificity, and concurrent drug therapy. The RIA:HPLC ratio of blood or plasma measurements will vary with the patient’s liver function, the time of blood sampling in reference to the time of drug administration, the absolute CsA concentration, and concurrent use of drugs that may alter the metabolism of CsA. The RIA assay should be used in conjunction with HPLC for trough blood or plasma measurement during the first postoperative weeks, during periods of changing hepatic function, and during changing drug regimens. In the future, the specific measurement of active or toxic metabolites of CsA should improve trough CsA concentration monitoring in OLT patients.

Acknowledgments

Supported in part by Grant 5RO1AM34475, National Institute of Arthritis, Diabetes, Digestive, and Kidney Diseases, and by Sandoz Pharmaceuticals, East Hanover. NJ.

References

1. Burckart GJ, Venkataramanan R, Ptachcinski RJ, et al. J Clin Pharmacol. (in press) [PubMed]
2. Ptachcinski RJ, Carpenter BJ, Burckart GJ, et al. N Engl J Med. 1985;313:1416. [PubMed]
3. Ptachcinski RJ, Burckart GJ, Venkataramanan R. J Clin Pharmacol. 1986;26:358. [PubMed]
4. Ptachcinski RJ, Venkataramanan R, Rosenthal JT, et al. Clin Pharmacol Ther. 1985;38:296. [PubMed]
5. Ptachcinski RJ, Venkataramanan R, Burckart GJ. Clin Pharmacokinet. 1986;11:107. [PubMed]
6. Venkataramanan R, Yang S, Burckart GJ, et al. Ther Drug Monit. (in press)
7. Zitelli BJ, Gartner JC, Malatack JJ, et al. Transplant Proc. 1983;15:2592. [PMC free article] [PubMed]
8. Najarian JS, Fryd DS, Strand M, et al. Ann Surg. 1985;201:142. [PubMed]
9. Ptachcinski RJ, Hakala TR, Schleicher C, et al. Transplant Proc. (in press)
10. Klintmalm G, Sawe J, Ringden O, et al. Transplantation. 1985;39:132. [PubMed]
11. Canadian Multicentre Transplant Study Group. N Engl J Med. 1983;309:809. [PubMed]
12. Merion RM, White DJG, Thiru S, et al. N Engl J Med. 1984;310:148. [PubMed]
13. Keown PA, Stiller CR, Sinclair NR, et al. Transplant Proc. 1983;15:2438.
14. Kahan BD, Wideman CA, Reid M, et al. Transplant Proc. 1984;16:1195. [PubMed]
15. Yee GC, Kennedy MS, McGuire BS, et al. Drug Intell Clin Pharm. 1985;19:445.
16. Cooley DA, Frazier OH, Painvin GA, et al. Transplant Proc. 1983;15:2567.
17. Painvin GA, Okereke OUJ, Frazier OH, et al. Transplant Proc. 1985;17:223.
18. Starzl TE, Iwatsuki S, Shaw BW, et al. Transplant Proc. 1984;17:250.
19. Abisch E, Beveridge T, Gratwohl A, et al. Pharm Week Sci Ed. 1982;4:84. [PubMed]
20. Donatsch P, Abisch E, Homberger M, et al. J Immunoassay. 1981;2:19. [PubMed]
21. Carruthers SG, Freeman DJ, Koegler JC, et al. Clin Chem. 1983;29:180. [PubMed]
22. Yee GC, Kennedy MS, Storb R, et al. Transplantation. 1984;38:511. [PubMed]
23. Burckart GJ, Starzl TE, Williams L, et al. Transplant Proc. 1985;17:1172. [PMC free article] [PubMed]
24. Blyden GT, Franklin C, Cho SI, et al. J Clin Pharmacol. 1986;26:367. [PubMed]
25. Klintmalm G, Sawe J. Lancet. 1984;1:731. [PubMed]
26. Ost L, Klintmalm G, Ringden O. Transplant Proc. 1985;17:1252.
27. Ptachcinski RJ, et al. Transplant Proc. (in press)
28. Morgenstern GR, Powles R, Robinson R, et al. Lancet. 1982;2:1342. [PubMed]
29. Ferguson RM, Sutherland DER, Simmons RL, et al. Lancet. 1982;2:882. [PubMed]
30. White DJG, Blatchford NR, Cauwenberg G. Transplantation. 1984;37:214. [PubMed]
31. Ptachcinski RJ, Carpenter BJ, Burckart GJ, et al. N Engl J Med. 1985;313:1416. [PubMed]
32. Freeman DJ, Laupacis A, Keown PA, et al. Br J Clin Pharmacol. 1984;18:887. [PMC free article] [PubMed]
33. Keown PA, Stiller CR, Laupacis AL, et al. Transplant Proc. 1982;14:659. [PubMed]
34. Allen RD, Hunnisett AG, Morris RJ. Lancet. 1985;1:980. [PubMed]
35. Van Buren D, Wideman CA, Reid M, et al. Transplant Proc. 1984;16:1642. [PubMed]
36. Burckart GJ, Venkataramanan R, Starzl TE, et al. J Clin Pharmacol. 1984;24:412.
37. Wallwork J, McGregor OGA, Wells FC, et al. Lancet. 1983;1:366. [PubMed]
38. Maurer G. Transplant Proc. 1985;17:19. [PubMed]