PMCCPMCCPMCC

Search tips
Search criteria 

Advanced

 
Logo of nihpaAbout Author manuscriptsSubmit a manuscriptHHS Public Access; Author Manuscript; Accepted for publication in peer reviewed journal;
 
Arterioscler Thromb Vasc Biol. Author manuscript; available in PMC 2010 November 1.
Published in final edited form as:
PMCID: PMC2775706
NIHMSID: NIHMS149305

FVII, FVIIa and downstream markers of extrinsic pathway activation differ by EPCR Ser219Gly variant in healthy men

Abstract

Objective:

To determine the effect of a variant in EPCR (Ser219Gly), previously shown to affect EPCR shedding, upon plasma FVII, FVIIa and downstream markers of activated coagulation.

Methods:

Statistical analysis was undertaken in ~2000 healthy middle aged men (NPHSII)

Results:

Higher soluble EPCR levels were confirmed for Gly allele carriers (p<0.0001). Significantly higher levels of FVII, FVIIa and downstream markers of activated coagulation in the extrinsic pathway (FIX activation pep {FIXpep}; FX activation pep {FXpep}), and prothrombin F1+2 (F1+2) were identified in baseline samples, in Gly carriers compared to Ser/Ser (p<=0.04 for trend). In repeat samples collected for up to five years, levels of FVII and F1+2 were higher in Gly allele carriers compared to Ser/Ser by (FVII: 6.9% CI 5.5-8.4 in Ser/Gly; and 23.4% CI 16.3-30.8 in Gly/Gly, p<0.0001), (F1+2: 8.1% CI 5.2-11.1 in Ser/Gly; 25.2% CI 11.8-40.3 in Gly/Gly, p<0.04), confirming reproducibility of findings at baseline. Molar ratios for FIXpep, FXpep and F1+2 to FVIIa were constant in Ser/Ser and Ser/Gly but tended to be higher in Gly/Gly, reaching statistical significance for FIXpep:FVIIa (p=0.04).

Conclusions:

These data suggest that higher levels of FVII and FVIIa circulate when EPCR shedding is greatest. Furthermore, these results suggest consequences for activation of extrinsic coagulation.

Keywords: Endothelial protein C receptor, FVIIa, extrinsic coagulation, FIX activation peptide, FX activation peptide, prothrombin F1+2

Introduction

Endothelial protein C receptor (EPCR) plays an important role in the inhibition of thrombin generation by its participation in the PC pathway.1 As an integral endothelial membrane protein it captures circulating PC and presents it to an adjacent thrombin-thrombomodulin complex which activates the PC with a consequent inhibition of coagulation factors Va and VIIIa, resulting in reduced thrombin generation.1 We and others have previously reported altered functional characteristics associated with an amino acid change within the membrane spanning region of EPCR (Ser219Gly), both by in vitro analysis2,3 and in data derived from ex vivo plasma samples.2,4,5,6 Increased thrombin generation, as determined by prothrombin F1+2 (F1+2) levels, was found in those with the EPCR 219Gly allele in a large study of patients with type 2 diabetes and in healthy individuals within the large prospective study of heart disease, Northwick Park Health Study II (NPHSII).2 A large difference in soluble EPCR levels across EPCR Ser219Gly genotype groups is now well established both in health and disease, with at least 70% of the variance of soluble EPCR levels in plasma being caused by the EPCR Ser219Gly variant. 2,,4,5,6 In vitro analysis has confirmed increased shedding of EPCR in those with the Gly allele.2,3

Recent in vitro analysis by surface plasmon resonance of FVIIa passed over soluble EPCR bound to the surface,7 and cell surface EPCR binding to both FVII and FVIIa8 has suggested that EPCR also acts as a cellular receptor for activated factor VII (FVIIa) and FVII on endothelium. FVIIa and FVII bound to EPCR with a similar affinity compared to binding of PC and activated PC to EPCR.8 Furthermore, FVIIa that had bound to EPCR was unable to accelerate either FVIIa activation of FX, or to activate protease activated receptors.8 FVIIa endocytosis was also facilitated by its binding to EPCR.8 EPCR binding is therefore suggested as a clearance mechanism for FVIIa. An in vitro study has also shown that blocking the FVII binding site of EPCR on the endothelial surface increased the generation of FXa by FVIIa, further suggesting a physiological haemostatic consequence of EPCR-FVIIa binding.9 Soluble EPCR was shown to dose-dependently inhibit the activation of FX by the FVIIa-tissue factor (TF) complex.9 These findings suggest, in terms of the FVII/FVIIa binding, that higher levels of endothelial, or soluble EPCR may shift haemostatic balance towards anticoagulant activity, although it is difficult to predict the relative effects of these processes in vivo.

Within NPHSII, markers of coagulation activity have been measured at several steps along the extrinsic, or tissue factor pathway. A sensitive assay to the peptide liberated (FIXpep) with the generation of activated factor IX (FIXa)10 has demonstrated that FIXa generation in vivo results mainly from activity of the tissue factor pathway, rather than the contact or intrinsic pathway (factor XII, prekallikrein, high molecular weight kininogen, factor XI). Levels of FIXpep were shown to be reduced in hereditary FVII or FIX deficiency.10 Similarly, levels of FXpep were shown to be lower in patients with FVII deficiency. 11

In a recent study of NPHSII, a higher ratio of FIXpep:FVIIa was found to be an independent risk for heart disease12 and was as good as or better than the classic and inflammatory risk factors used in risk algorithms. In the current analysis of this large study of middle-aged men, healthy at the time of sampling, measurements of FVII and FVIIa13 have been assessed by EPCR Ser219Gly genotype, and the consequences of this upon activation of coagulation has been studied using activation markers within the extrinsic coagulation pathway (FIXpep and FXpep). Measurements of activated factor XII (FXIIa)14 and F1+2,15 were used also to determine any effect upon coagulation outside the extrinsic pathway, and thrombin generation, respectively.

Methods

Study Cohort

NPHSII is a prospective study of heart disease currently with 15 years follow-up. The study involved 2997 men who gave written informed consent, and was approved by the institutional ethics committee. Subjects did not fast prior to blood collection but were instructed to avoid heavy meals. They were also requested not to smoke or to take vigorous exercise from midnight before sampling.

EPCR genotyping

EPCR genotyping was determined using PCR, followed by restriction digest, and visualised using micro-array diagonal gel electrophoresis, as reported previously.2

Measurements of coagulation factors and markers of activated coagulation

For the current analysis, only samples without a questionable venepuncture performance were included, following a scoring system by predetermined criteria.16 FVII levels were measured by coagulant (FVIIc) and antigen (FVIIag) levels. Markers of an activated extrinsic pathway (FIXpep,10 FXpep11, FVIIa13), and a coagulation marker outside the extrinsic coagulation pathway (FXIIa, Axis-Shield, UK)14 together with a marker of thrombin generation (F1+2)15 were measured as described previously, in baseline samples.17 Numbers for those with genotype data corresponding to EPCR Ser219Gly and each coagulation marker, in baseline samples are as follows: FVIIc (n=2427), FVIIag (n=2273), FVIIa (n=1086), FIXpep (n=1259), FXpep (n=1120), FXIIa (n=1970), F1+2 (n=2188).

In addition, FVIIc levels had been measured in samples collected at 1, 2, 3, 4, and 5 years and F1+2 levels had been measured at 1, 2, 3 and 4 years. This data was used to determine the reproducibility of findings in baseline samples. Only those who had both genotyping data and coagulation markers for each year were included in this analysis (FVIIc n=1564; F1+2 n=1147).

Measurement of sEPCR levels

sEPCR levels were measured specifically for this study using an ELISA assay (Diagnostica Stago, Reading, UK). Baseline (n=84) or 1 year (n=15) samples from both individuals who did and did not develop a CHD event and within each genotype group were randomly selected for assay. For those homozygous for the rare allele, all available samples were used (n=11). Eleven samples would have 90% power to detect a 1.5-fold difference between those homozygous for the rare allele compared to those with both common alleles. Previous findings have shown a 3.9-fold difference between sEPCR levels between these two groups. All samples were measured in duplicate, the mean of each pair being recorded. sEPCR levels were also measured in samples at 2 (n=99) and 5 years (n=99) for the same individuals. Inter-assay coefficient of variation for the sEPCR assay was 9.7%, 9.9% and 13.1% for three different control samples.

Statistical analysis

Levels of coagulation markers were log-transformed. Geometric mean levels and approximate SD were used throughout. Effect of genotype upon baseline levels was tested using both a co-dominant and an additive genetic model. Adjustments were made by analysis of covariance. Coagulation markers by genotype group and across years used repeated measures analysis of variance using those with complete data for all years. Follow-up visit was treated as a categorical variable and an additive model was used for genotype to give a test for trend across the three genotype groups. B coefficients were exponentiated to obtain an estimate of the percentage increase for each category. Differences in the effect of genotype over time were assessed by fitting an interaction term.

Results

Levels of FVIIc, FVIIag and FVIIa in baseline samples by EPCR Ser219Gly variant

All three measurements showed a statistically significant increasing trend from lowest levels in Ser/Ser, to higher levels in Ser/Gly with the highest levels in those who were Gly/Gly, p<=0.04, Figure 1. Similarly, for all three measurements, levels were significantly higher in a combined group with at least one Gly allele compared to those with only Ser alleles (p<=0.04), Figure 1. The significance of the associations with EPCR Ser219Gly after adjustment for confounders (centre, age, smoking, creatinine, CRP) were: p<0.0001 for FVIIc; p<0.0001 for FVIIag; p=0.05 for FVIIa, confirming the significance of each association.

Figure 1
Box-plots show median levels and inter-quartile range for FVIIc (A), FVIIag (B) and FVIIa (C) by EPCR Ser219Gly (S/G) variant in baseline samples. Seven outliers (above the scale) for FVIIag and 5 outliers for FVIIa are not shown. Below are shown geometric ...

Markers of activated coagulation downstream from FVIIa, in baseline samples, by EPCR Ser219Gly variant

To determine whether an increase in circulating FVII and FVIIa could have consequences for down-stream events in the extrinsic coagulation pathway, FIXpep, FXpep and thrombin generation (F1+2) were analysed. Both FXpep (p=0.04) and FIXpep (p=0.01) were elevated in those who were heterozygous and homozygous for EPCR 219Gly compared to non-carriers and showed a statistically significant trend, p<=0.04, Figure 2. FXIIa however, a coagulation marker outside the extrinsic system, showed no significant difference in levels by variant group (p>=0.73), Figure 2. The previously reported significantly higher F1+2 levels by EPCR genotype in these healthy middle aged men2 are included here also for completeness. F1+2 levels were significantly higher in the EPCR 219Gly carrier groups (p=0.001), and by trend, p=0.0001, Figure 2. These results show slightly different geometric mean levels to those in the previous publication2 due to removal, in the current study, of those individuals whose blood sampling was thought to be of inadequate quality. This did not however, change the statistical significance of the results. The significance of the associations with EPCR variant site after adjustment for potential confounders, (centre, age, smoking, creatinine, CRP) were: p=0.12 for FIXpep; p=0.07 for FXpep; p=0.05 for FVIIa; p=0.0005 for F1+2. While the association with fragments intermediate in the tissue-factor pathway became statistically borderline, after this adjustment, the marker of thrombin generation, F1+2 remained highly statistically significant.

Figure 2
Box-plots show median levels and inter-quartile range for FXpep (A), FIXpep (B), F1+2 (C) and FXIIa (D) by EPCR Ser219Gly (S/G) variant in baseline samples. Three outliers (above the scale) for FXpep, 10 outliers for FIXpep, 3 outliers for F1+2 and 3 ...

Reproducibility of FVIIc and F1+2 levels, across 4 to 5 years, by EPCR Ser219Gly variant

Levels of FVIIc and F1+2 across 5 years and 4 years, respectively, in those with complete data for all time points, were analysed by EPCR Ser219Gly, Table 1. FVIIc and prothombin F1+2 levels increased significantly over time in those who were Ser/Ser (p<0.0001) and Ser/Gly (p<0.0005). While levels were considerably higher in those in those who were Gly/Gly compared to the other variant groups, there was no significant increase in either FVIIc or F1+2 levels from baseline to 4 or 5 years (p>0.42). Results were remarkably consistent across the years by the EPCR variant site for both FVIIc and F1+2, with levels by variant site being highly statistically significant at each year (p<=0.0001 for FVIIc), Table 1A; (p<=0.04 for F1+2), Table 1B. The effect of EPCR variant was consistent over time, as no significant interaction for genotype with time was identified (p=0.68 for FVIIc and p=0.85 for F1+2). When the effect over all years was estimated by repeated measures ANOVA, with year of follow-up fitted as a categorical variable, levels of FVIIc and F1+2 were higher according to the number of Gly alleles carried (p<0.0001). After adjustment for the differences between years, levels of FVIIc in Ser/Gly were 6.9% (95% CI: 5.5 to 8.4) higher than in Ser/Ser and in Gly/Gly were 23.4% (95 % CI: 16.3 to 30.8) higher, Table 1A. Similarly after adjustment F1+2 levels were 8.1% (95% CI: 5.2 to 11.1) higher in Ser/Gly than in Ser/Ser and 25.2% (95% CI: 11.8 to 40.3) higher in Gly/Gly, Table 1B.

Molar ratios of coagulation activation markers, in baseline samples, by EPCR Ser219Gly variant

In line with the other coagulation activation markers, which were reported as molar concentrations, FVIIa was converted to a molar concentration using a molecular weight estimation of 51.6 kDaltons. Molar ratios for FXpep: FVIIa, FIXpep: FVIIa and F1+2: FVIIa were calculated to determine whether they differed by EPCR variant. While levels of the three extrinsic pathway activation markers (FVIIa, FIXpep and FXpep) and a marker of thrombin generation (F1+2) were higher in carriers of the Gly allele, molar ratios for these three activation markers to FVIIa levels were constant in Ser/Ser and Ser/Gly, Figure 3. However, although numbers were small, there was a tendency towards higher molar ratios in those who were Gly/Gly, which reached statistical significance for the ratio of FIXpep: FVIIa (1.8-fold higher than in non-carriers, p=0.04), and >1.3-fold higher than in non-carriers for the other two ratios (p=0.20 for F1+2:FVIIa; p=0.10 for FXpep:FVIIa).

Figure 3
Box-plots show median levels and inter-quartile range for molar ratios of FXpep:FVIIa (A), FIXpep:FVIIa (B), F1+2:FVIIa (C) by EPCR Ser219Gly (S/G) variant in baseline samples. Below are shown geometric mean levels (+/−SD) and statistical analysis ...

Levels of sEPCR across Ser219Gly genotype

To confirm previous results that sEPCR levels differ by Ser219Gly genotype, baseline (or year 1) samples were assessed across the genotype groups. No significant difference could be found between the samples at baseline (n=84) and year 1 (n=15, p=0.52) and accordingly, these were assessed as one group. Significantly higher levels were identified for those with the Gly allele, as expected (p<0.0001, both unadjusted and adjusted for those who later had a CHD event). Geometric mean levels in Ser/Ser were 82.6 (SD 34.6, n=54) ng/ml; in Ser/Gly were 212.4 (SD 87.6, n=34) and in Gly/Gly were 270.5 (SD 233.0, n=11). sEPCR levels were significantly higher in year 2 and in year 5 samples compared to baseline (or year 1), both within genotype groups (Table 1) and overall (geometric mean (SD): baseline or year 1, 130.3 (90.8) n=99; year 2, 149.3 (102.4) n=99; year 5, 142.7 (97.6) n=99; p<0.0001). sEPCR levels were analysed across all genotype groups by correlation with FVII levels and with the coagulation activation markers in baseline or (year 1) samples. Significant positive correlations were identified with FVII levels (FVIIc r=0.41, n=98, p<0.0001; FVIIag r=0.31, n=94, p=0.003). Significant or borderline significant correlations were identified also with each extrinsic pathway activation marker (FVIIa r=0.28, n=53, p=0.04; FIX activation peptide r=0.30, n=44, p=0.05; FX activation peptide r=0.27, n=37, p=0.11) and with prothrombin F1+2 levels (r=0.22, n=90, p=0.04), but not with FXIIa (r=−0.03, n=88, p=0.78). The correlation between FVIIc and sEPCR levels appeared higher within Ser/Gly (FVIIc r=0.42, n=34, p=0.01) compared to Ser/Ser, which showed no significant correlation (r=0.11, n=53, p=0.42,) and even higher in Gly/Gly (r=0.64, n=11, p=0.03), although numbers were small in this group. Correlations between the extrinsic pathway activation markers and sEPCR were not significantly correlated in Ser/Ser, but became significantly correlated in Ser/Gly for FVIIa (r=0.64, p=0.001, n=23) and FIX pep (r=0.54, p=0.01, n=21). Insufficient paired measurements were available for correlation analysis of FVIIa, FIXpep and FX pep in Gly/Gly. F1+2 levels only became borderline significantly correlated with sEPCR within Gly/Gly, r=0.61, n=9, p=0.08, although numbers were small.

Discussion

Previous studies have shown a large difference in soluble EPCR levels across EPCR Ser219Gly variant groups, being 2-fold higher in Ser/Gly and 4-fold higher in Gly/Gly compared to non-carriers of Gly.2,4,5,6 The current analysis has confirmed the higher levels of sEPCR identified for the Gly allele. The large variability in levels for the ‘Gly’ allele, which can be seen in the current study by the large SD for the Gly allele has been suggested to be caused at least in part by alternative splicing of the mRNA for this allele, resulting in a longer protein that is expressed, but which does not associate with the membrane. A minor portion of plasma sEPCR has been identified as this alternatively spliced variant in carriers of the Gly allele18. It has been suggested that the plasma level of the alternatively spliced variant may be related to inflammatory processes18. The levels of sEPCR in the current study were measured in health and as the alternatively spliced variant would be expected to be present in only minor amounts, would not be expected to account for the findings in the current study.

The current data would support the concept that reduced amounts of EPCR on the surface of endothelium, due to increased shedding, in EPCR Gly carriers, has a consequence for reduced binding of FVII and FVIIa, resulting in higher circulating levels of these coagulation pathway proteins. These findings extend those reported for binding of FVII and FVIIa to surface expressed EPCR by in vitro analysis,7,8,9 and suggest that binding of FVII and FVIIa may have physiologic significance. Analysis of FVIIc levels over 5 years in a large number of samples confirmed the effect of the EPCR variant site upon levels and gives strong evidence for the reproducibility of the results.

The finding of higher levels of down-stream activation markers for the extrinsic pathway (FIXpep, FXpep) but not for a coagulation marker outside of the extrinsic pathway (FXIIa) suggests that the reduced binding of FVIIa in those with the Gly allele may have consequences for activation of these coagulant proteins, resulting in an increase in thrombin generation (F1+2). Again, as for FVIIc levels over 5 years, the consistent effect of the variant site upon F1+2 levels over 4 years gives strong evidence for the reproducibility of these results.

The question arises as to whether the increased activation through the extrinsic pathway is directly related to the lower FVII and FVIIa binding to the endothelial cell surface or via another mechanism. In this regard, it may be expected that reduced amounts of EPCR on the surface of endothelium would impact upon PC binding also, leading to reduced activated PC generation in Gly carriers. The consequence of this would be reduced inhibition of the thrombin feedback loop leading potentially to an increase in FIXpep, FXpep and F1+2 levels. FVIIa levels, however, would not be expected to increase in this case, as it has been suggested that thrombin is probably not a physiologically important activator of FVII in vivo19. To disentangle the potential consequences of increased FVIIa level per se upon downstream activation of the extrinsic coagulation system, compared to the consequences of reduced amounts of activated PC generation, a molar ratio of each downstream activated coagulation marker to FVIIa was calculated.

While the increase in FVIIa levels in Ser/Gly was statistically significant compared to Ser/Ser, the percentage increase was small. For this small increase in FVIIa level in heterozygotes, the molar ratio of each activation marker in the extrinsic coagulation system to FVIIa was constant, compared to each ratio in Ser/Ser, suggesting that the higher FVIIa level in carriers of one Gly allele leads to an equally high ‘knock-on’ effect of downstream activation.

The tendency towards an increased molar ratio for FIXpep: FVIIa (1.8-fold), FXpep: FVIIa (1.6-fold) and F1+2: FVIIa (1.3-fold) in those homozygous for Gly, however, does suggest that further deregulation of activated coagulation down-stream from FVIIa is likely in those with the highest levels of EPCR shedding. Tissue factor pathway inhibitor (TFPI) is the most important regulator of the FVIIa-tissue factor complex, but differences in levels of TFPI would not be expected to differ by EPCR variant and account for these results. The altered ratio may represent the added effect of a de-regulated PC pathway, with reduced inhibition of the thrombin feedback loop, but requires further study. Collectively, the findings suggest two physiological roles for endothelial EPCR in the regulation of thrombin generation: Binding and clearance of FVIIa, in addition to regulation of the thrombin feedback loop.

In-vitro analysis has suggested that FVII and FVIIa will bind soluble EPCR in addition to endothelial-bound EPCR and that soluble EPCR-bound FVIIa has reduced ability to activate FX9. The higher soluble EPCR levels associated with the Gly allele, therefore, may be expected to compensate for the reduced endothelial located EPCR, but it is not clear what the importance of this mechanism would be in vivo. This finding is in contrast to activated PC binding to soluble EPCR, which unlike membrane-bound EPCR has been suggested to inhibit the functional activity of activated PC, rather than promote it.20 In mice, it has been suggested that only supra-physiologic levels of soluble EPCR could influence PC activation and exaggerate the coagulant response.21 This is a complicated dynamic physiological process, therefore, and it is difficult to predict what would actually happen in vivo, from in vitro studies. The current study, has not addressed the relative contribution of the endothelial versus circulating levels of soluble EPCR to bind FVII and FVIIa, nor the relative effects of the membrane versus circulating compartments of EPCR-FVIIa complex upon downstream haemostasis. However, the results have suggested that in health, when EPCR shedding is high (Gly/Gly), the balance of these processes leads to relatively higher downstream activation of extrinsic coagulation, determined by molar ratios of the downstream activation markers to FVIIa, than was observed for the other two genotype groups. At an intermediate level of EPCR shedding (Ser/Gly), while increased FVIIa levels paralleled an increased activation of extrinsic coagulation, the relative amounts of FVIIa and downstream activation markers were constant (determined by molar ratios), compared to those who have the lowest level of EPCR shedding.

These findings, in Ser/Ser compared to Gly/Gly, help the understanding of the 3-fold elevation in risk for heart disease for Gly/Gly identified previously in NPHSII2 and extend the findings for the association of a higher FIXpep:FVIIa in those with heart disease without reference to genotype in NPHSII also.12 The small increase in extrinsic coagulation markers measured in health in heterozygotes for Gly in the current study does not detrimentally affect clinical outcome for heart disease.2 In these heterozygotes, the molar ratio of FIXpep: FVIIa did not increase above that seen for Ser/Ser and further suggests the usefulness of this molar ratio in prediction of risk for heart disease.

As stated previously, analysis of NPHSII has shown a higher molar ratio for FIXpep:FVIIa in baseline samples in those who went on to have a heart disease event.12 This ratio was due to both higher FIXpep levels and lower FVIIa levels in those who later developed a heart disease event. The potential explanation for these results was through increased amounts of intravascular tissue factor, with the lower FVIIa levels suggested to arise because of binding of FVIIa to tissue factor and loss of circulating measureable FVIIa. In contrast, while the current analysis would suggest that homozygotes for EPCR 219Gly are haemostatically compromised by an increased FIXpep:FVIIa molar ratio and were previously associated with heart disease in NPHSII2, we have shown FVIIa levels to be higher in Gly/Gly. So these results indicate two situations associated with risk for development of heart disease, in healthy individuals: High FIXpep, low FVIIa, high FIXpep:FVIIa ratio across all individuals in NPHSII; and high FIXpep, high FVIIa, high FIXpep:FVIIa ratio in EPCR 219Gly homozygotes.

In summary, we have extended previous in vitro analysis which showed that FVII and FVIIa bind endothelial and sEPCR, by providing evidence that a functional variant site in EPCR has consequences both for plasma levels of FVIIa and for downstream activation of the extrinsic coagulation pathway. The stability of these results across 4 to 5 years, shown for FVIIc and F1+2 levels in this very large study, provides strong evidence for the variant effect. These results have also extended a previous study of NPHSII, suggesting that an increased ratio of FIXpep:FVIIa is associated with future development of heart disease. The consequences of the findings for the EPCR variant site for heart disease and other conditions associated with increased inflammatory or thrombotic processes, require further study.

Limitations of the study

The ability to measure activated PC in this study would have been useful but is not possible as samples require collection into a specific anticoagulant cocktail.

Acknowledgements

a) Sources of Funding – The NPHSII recruitment and monitoring was supported by the British Medical Research Council, the National Institutes of Health (HL-33014 and HL-54502). SEH and JAC are supported by the British Heart Foundation (RG 2005/014) and HI is supported by the Coronary Thrombosis Trust.

b) Acknowledgments – The authors would like to dedicate this manuscript to George Miller, who was principal investigator for NPHSII, responsible for its initiation and recruitment but who sadly died before initiation of the current analysis. We thank also the primary care practices for their collaboration in the recruitment phase of NPHSII. HI conceived and designed the research, analysed and interpreted the data and drafted the manuscript; JAC and FD performed statistical analysis; JA and JPM were responsible for the sEPCR assay; assays for other coagulation activation assays were performed in the laboratories of JHM, MPE and KAB; genetic analysis was performed in the laboratory headed by SEH, who is also principal investigator for NPHSII; all authors gave critical input to all or parts of the manuscript.

Footnotes

c) Disclosure – HAI, JAC, FD, JA, JPM, KAB, SEH – none; JHM has royalty income from patents related to assays used in this work; MPE licensed the technology for the FXIIa assay to Axis-Shield.

References

1. Esmon CT. Inflammation and the activated protein C anticoagulant pathway. Semin Thromb Hemost. 2006;32:49–60. [PubMed]
2. Ireland H, Konstantoulas CJ, Cooper JA, Hawe E, Humphries SE, Mather H, Goodall AH, Hogwood J, Juhan-Vague I, Yudkin JS, Di Minno G, Margaglione M, Hamsten A, Miller GJ, Bauer KA, Kim YT, Stearns-Kurosawa DJ, Kurosawa S. EPCR Ser219Gly: elevated sEPCR, F1+2, risk for coronary heart disease, and increased sEPCR shedding in vitro. Atherosclerosis. 2005;183:283–292. [PubMed]
3. Qu D, Wang Y, Song Y, Esmon NL, Esmon CT. The Ser219-->Gly dimorphism of the endothelial protein C receptor contributes to the higher soluble protein levels observed in individuals with the A3 haplotype. J Thromb Haemost. 2006;4:229–235. [PubMed]
4. Saposnik B, Reny JL, Gaussem P, Emmerich J, Aiach M, Gandrille S. A haplotype of the EPCR gene is associated with increased plasma levels of sEPCR and is a candidate risk factor for thrombosis. Blood. 2004;103:1311–1318. [PubMed]
5. Uitte de Willige S, Van Marion V, Rosendaal FR, Vos HL, de Visser MC, Bertina RM. Haplotypes of the EPCR gene, plasma sEPCR levels and the risk of deep venous thrombosis. J Thromb Haemost. 2004;2:1305–1310. [PubMed]
6. Medina P, Navarro S, Estelles A, Voya A, Woodhams B, Mira Y, Villa P, Migaud-Fressart M, Ferrando F, Aznor J, Bertina RM, Espana F. Contribution of polymorphisms in the endothelial protein C receptor gene to soluble endothelial protein C receptor and circulating activated protein C levels and thrombotic risk. Thrombosis and Haemostasis. 2004;91:905–911. [PubMed]
7. Preston RJ, Ajzner E, Razzari C, Karageorgi S, Dua S, Dahlbäck B, Lane DA. Multifunctional specificity of the protein C/activated protein C Gla domain. J Biol Chem. 2006;281:28850–28857. [PubMed]
8. Ghosh S, Pendurthi UR, Esmon CT, Rao LV. Endothelial cell protein C receptor acts as a cellular receptor for factor VIIa on endothelium. J Biol Chem. 2007;282:11849–11857. [PMC free article] [PubMed]
9. López-Sagaseta J, Montes R, Puy C, Díez N, Fukudome K, Hermida J. Binding of factor VIIa to the endothelial cell protein C receptor reduces its coagulant activity. J Thromb Haemost. 2007;5:1817–1824. [PubMed]
10. Bauer KA, Kass BL, ten Cate H, Hawiger JJ, Rosenberg RD. Factor IX is activated in vivo by the tissue factor mechanism. Blood. 1990;76:731–736. [PubMed]
11. Bauer KA, Kass BL, ten Cate H, Bednarek MA, Hawiger JJ, Rosenberg RD. Detection of factor X activation in humans. Blood. 1989;74:2007–2015. [PubMed]
12. Miller GJ, Ireland HA, Cooper JA, Bauer KA, Morrissey JH, Humphries SE, Esnouf MP. Relationship between markers of activated coagulation, their correlation with inflammation, and association with risk for coronary heart disease (NPHSII) J Thromb Haemost. 2007 deceased. Epub ahead of print. [PubMed]
13. Morrissey JH, Macik BG, Neuenschwander PF, Comp PC. Quantitation of activated factor VII levels in plasma using a tissue factor mutant selectively deficient in promoting factor VII activation. Blood. 1993;81:734–744. [PubMed]
14. Ford RP, Esnouf MP, Burgess AI, Sarphie A. An enzyme-linked immunosorbent assay (ELISA) for the measurement of activated factor XII (Hageman factor) in human plasma. J Immunoassay. 1996;17:119–131. [PubMed]
15. Teitel JM, Bauer KA, Lau HK, Rosenberg RD. Studies of the prothrombin activation pathway utilizing radioimmunoassays for the F2/F1 + 2 fragment and thrombin--antithrombin complex. Blood. 1982;59:1086–1097. [PubMed]
16. Miller GJ, Bauer KA, Barzegar S, Foley AJ, Mitchell JP, Cooper JA, Rosenberg RD. The effects of quality and timing of venepuncture on markers of blood coagulation in healthy middle-aged men. Thromb Haemost. 1995;73:82–86. [PubMed]
17. Cooper JA, Miller GJ, Bauer KA, Morrissey JH, Meade TW, Howarth DJ, Barzegar S, Mitchell JP, Rosenberg RD. Comparison of novel hemostatic factors and conventional risk factors for prediction of coronary heart disease. Circulation. 2000;102:2816–2822. [PubMed]
18. Saposnik B, Lesteven E, Lokajczyk A, Esmon CT, Aiach M, Gandrille S. Alternative mRNA is favored by the A3 haplotype of the EPCR gene PROCR and generates a novel soluble form of EPCR in plasma. Blood. 2008:3442–51. [PubMed]
19. Butenas S, Mann KG. Kinetics of human factor VII activation. Biochemistry. 1996;35:1904–1910. [PubMed]
20. Liaw PC, Neuenschwander PF, Smirnov MD, Esmon CT. Mechanisms by which soluble endothelial cell protein C receptor modulates protein C and activated protein C function. J Biol Chem. 2000;25:5447–5452. [PubMed]
21. Zheng X, Li W, Gu JM, Qu D, Ferrell GL, Esmon NL, Esmon CT. Blood. 2007;1:1003–1009. Effects of membrane and soluble EPCR on the hemostatic balance and endotoxemia in mice. [PubMed]