PMCCPMCCPMCC

Search tips
Search criteria 

Advanced

Logo of bmcgenoBioMed Centralsearchsubmit a manuscriptregisterthis articleBMC Genomics
 
From:
Published online Jul 4, 2009. doi: 10.1186/1471-2164-10-297
Table 1
Robustness of the GPlex4 and REPLI-g WGA kits.
IDGPlex4REPLI-g

Call-rate A1Call-rate B2WGAout3Call-rate A1Call-rate B2WGAout3
197.74%99.24%4.8699.42%99.65%6.55
297.41%99.30%4.8599.56%99.64%7.22
398.21%99.42%5.0698.54%99.33%3.53
497.80%99.38%4.9399.14%99.56%3.00
597.90%99.41%5.2099.00%99.51%4.47
698.04%99.42%4.9299.73%99.73%3.74
797.83%99.38%5.0099.72%99.73%6.02
897.62%99.29%5.0199.49%99.66%6.00
997.56%99.29%5.1599.55%99.64%7.64
1097.30%99.26%5.3395.91%99.15%7.86
1198.17%99.32%5.4199.43%99.60%7.48
1298.13%99.38%5.4999.38%99.56%1.56
1396.62%99.08%5.1599.43%99.60%6.71
1497.55%99.35%5.4899.22%99.63%1.40
1596.75%99.17%5.1498.97%99.53%4.98
1696.53%99.16%4.1398.49%99.43%2.72

Median97.68%99.31%5.1099.40%99.60%5.49
Std. Dev.0.53%0.10%0.330.92%0.15%2.18
1Call-rate (percent) using the Illumina Human610-Quadv1B cluster file.
2Call-rate (percent) using the WGA kit custom cluster file.
3wgaDNA (μg) produced per reaction.
Articles from BMC Genomics are provided here courtesy of
BioMed Central