1. Bomsdorf H, Helzel T, Kunz D, Roschmann P, Tschendel O, Wieland J. Spectroscopy and imaging with a 4 tesla whole-body MR system. NMR Biomed. 1988;1:151–8. [PubMed] 2. Vaughan JT, Garwood M, Collins CM, Liu W, DelaBarre L, Adriany G, Andersen P, Merkle H, Goebel R, Smith MB, Ugurbil K. 7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images. Magn Reson Med. 2001;46:24–30. [PubMed] 3. Saekho S, Yip CY, Noll DC, Boada FE, Stenger VA. Fast-kz three-dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity. Magn Reson Med. 2006;55:719–24. [PMC free article] [PubMed] 4. Ulloa JL, Irarrazaval P, Hajnal JV. Exploring 3D RF shimming for slice selective imaging. Proceedings of the 13th Annual Meeting of ISMRM; Miami Beach, Florida, USA. 2005. p. 21.
5. Sung K, Cunningham CH, Nayak KS. Validation of B1+ Non-uniformity Correction in the Chest at 3T using TIP-COMP. Proceedings of the 14th Annual Meeting of ISMRM; Seattle, Washington, USA. 2006. p. 597.
6. Ibrahim TS, Lee R, Baertlein BA, Abduljalil AM, Zhu H, Robitaille PM. Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn Reson Imaging. 2001;19:1339–47. [PubMed] 7. Mao W, Smith MB, Collins CM. Exploring the limits of RF shimming for high-field MRI of the human head. Magn Reson Med. 2006;56:918–22. [PubMed] 8. Vaughan T, DelaBarre L, Snyder C, Tian J, Akgun C, Shrivastava D, Liu W, Olson C, Adriany G, Strupp J, Andersen P, Gopinath A, van de Moortele PF, Garwood M, Ugurbil K. 9.4T human MRI: preliminary results. Magn Reson Med. 2006;56:1274–82. [PubMed] 9. Silver MS, Joseph RI, Hoult DI. Highly selective 90° and 180° pulse generation. J Magn Reson. 1984;59:347–351.
10. Garwood M, DelaBarre L. The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. J Magn Reson. 2001;153:155–77. [PubMed] 11. Pauly J, Nishimura D, Macovski A. A k-space analysis of small-tip angle excitation. J Magn Reson. 1989;81:43–56.
12. Setsompop K, Zelinski AC, Goyal VK, Wald LL, Adalsteinsson E. Sparse spokes slice selective design for B1 inhomogeneity correction at 7T. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 356.
13. Katscher U, Bornert P, Leussler C, van den Brink JS. Transmit SENSE. Magn Reson Med. 2003;49:144–50. [PubMed] 14. Zhu Y. Parallel excitation with an array of transmit coils. Magn Reson Med. 2004;51:775–84. [PubMed] 15. Griswold M, Kannengiesser S, Muller M, Jakob P. Autocalibrated accelerated parallel excitation (transmit-GRAPPA). Proceedings of the 13th Annual Meeting of ISMRM; Miami Beach, FL, USA. 2005. p. 2435.
16. Grissom W, Yip CY, Zhang Z, Stenger VA, Fessler JA, Noll DC. Spatial domain method for the design of RF pulses in multicoil parallel excitation. Magn Reson Med. 2006;56:620–9. [PubMed] 17. Ullmann P, Junge S, Wick M, Seifert F, Ruhm W, Hennig J. Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels. Magn Reson Med. 2005;54:994–1001. [PubMed] 18. Setsompop K, Wald LL, Alagappan V, Gagoski B, Hebrank F, Fontius U, Schmitt F, Adalsteinsson E. Parallel RF transmission with eight channels at 3 Tesla. Magn Reson Med. 2006;56:1163–71. [PubMed] 19. Zhang Z, Yip CY, Grissom WA, Noll DC, Boada FE, Stenger VA. Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses. Magn Reson Med. 57:842–7. [PMC free article] [PubMed] 20. Setsompop K, Wald LL, Alagappan V, Gagoski BA, Adalsteinsson E. Magnitude Least Squares Optimization for Parallel RF Excitation Design Demonstrated at 7 Tesla with 8 Channels. Magn Reson Med. 2008;59:908–915. [PMC free article] [PubMed] 21. Ulloa JL, Callaghan M, Guarini M, Hajnal JV, Irarrazaval P. Calculation of B1 pulse for RF shimming at arbitrary flip angle using multiple transmitters. Proceedings of the 14th Annual Meeting of ISMRM; Seattle, Washington, USA. 2006. p. 3016.
22. Grissom WA, Fessler JA, Noll DC. Time-Segmented Spin Domain Method for Fast Large-Tip-Angle RF pulse Design in Parallel Excitation. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 676.
23. Grissom WA, Fessler JA, Noll DC. Additive-Angle Method for Fast Large-Tip-Angle RF Pulse Design in Parallel Excitation. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 1689.
24. Setsompop K, Zelinski AC, Alagappan V, Hebrank F, Fontius U, Schmitt F, Wald LL, Adalsteinsson E. High flip angle slice selective Parallel RF Excitation on an 8-channel system at 3T. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 677.
25. Xu D, King KF, Zhu Y, McKinnon G, Liang Z. Multidimensioinal Arbitrary-Flip-Angle Parallel Transmit Pulse Design Using an Optimal Control Approach. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 1696.
26. Xu D, King KF, Zhu Y, McKinnon GC, Liang ZP. A noniterative method to design large-tip-angle multidimensional spatially-selective radio frequency pulses for parallel transmission. Magn Reson Med. 2007;58:326–334. [PubMed] 27. Pauly J, Nishimura D, Macovski A. A linear class of large-tip-angle selective excitation pulses. J Magn Reson. 1989;82:571–587.
28. Kerr AB, Zhu Y, Pauly JM. Phase Constraint Relaxation in Parallel Excitation Pulse Design. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 1694.
29. Pauly J, Le Roux P, Nishimura D, Macovski A. Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm. IEEE Transactions on Medical Imaging. 1991;10:53–65. [PubMed] 30. Xu D, King KF, Zhu Y, McKinnon G, Liang Z. Reducing B1 Inhomogeneity Using Optimized Parallel Transmit Pulses. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 1700.
31. Press WH. Numerical recipe in C. Cambridge University Press; Cambridge: 1992.
32. Conolly SM, Nishimura DG, Macovski A, Glover GH. Variable-rate selective excitation. J Magn Reson. 1988;78:440–458.
33. Wu X, Akgun C, Vaughan JT, Ugurbil K, van de Moortele PF. SAR Reduction in Transmit SENSE Using Adapted Excitation k-space Trajectories. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 673.
34. Graesslin I, Biederer S, Schweser F, Zimmermann KH, Katscher U, Börnert P. SAR Reduction for Parallel Transmission using VERSE and k-space Filtering. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 674.
35. Setsompop K, Zelinski AC, Alagappan V, Nistler J, Hebrank F, Fontius U, Schmitt F, Wald LL, Adalsteinsson E. In vivo Parallel RF Excitation with B0 correction. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 671.
36. Alagappan V, Adalsteinsson E, Setsompop K, Fontius U, Zelinski AC, Wiggins GC, Hebrank F, Schmitt F, Wald LL. Comparison of Three Transmit Arrays for Parallel Transmit. Proceedings of the 15th Annual Meeting of ISMRM; Berlin, Germany. 2007. p. 35.
37. Lin FH, Kwong KK, Belliveau JW, Wald LL. Parallel imaging reconstruction using automatic regularization. Magn Reson Med. 2004;51:559–67. [PubMed] 38. Setsompop K, Alagappan V, Gagoski B, Witzel T, Polimeni J, Potthast A, Hebrank F, Fontius U, Schmitt F, Wald LL, Adalsteinsson E. Slice-Selective RF pulses for In-vivo B1+ Inhomogeneity Mitigation at 7 Tesla using Parallel RF Excitation with a 16-Element Coil. Magn Reson Med accepted for publication. [PMC free article] [PubMed]