PMCCPMCCPMCC

Search tips
Search criteria 

Advanced

 
Logo of taosLink to Publisher's site
 
Trans Am Ophthalmol Soc. 2003; 101: 417–436.
PMCID: PMC1358999

Light-adjustable lens.

Abstract

PURPOSE: First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS: After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cytotoxicity, leaching, precision of adjustment, optical quality after adjustment, and mechanical properties. Light-adjustable IOLs were then tested in vivo for biocompatibility and precision of adjustment in a rabbit model. In collaboration with Zeiss-Meditec, a digital LDD was developed and tested to correct for higher-order aberrations in light-adjustable IOLs. RESULTS: The results establish that a biocompatible silicone IOL can be fabricated and adjusted using safe levels of light. There was no evidence of cytotoxicity or leaching. Testing of mechanical properties revealed no significant differences from commercial controls. Implantation of light-adjustable lenses in rabbits demonstrated- excellent biocompatibility after 6 months, comparable to a commercially available IOL. In vivo spherical (hyperopic and myopic) adjustment in rabbits was achieved using an analog light delivery system. The digital light delivery system was tested and achieved correction of higher-order aberrations. CONCLUSION: A silicone light-adjustable IOL and LDD have been developed to enable postoperative, noninvasive adjustment of lens power. The ability to correct higher-order aberrations in these materials has broad potential applicability for optimization of vision in patients undergoing cataract and refractive surgery.

Full Text

The Full Text of this article is available as a PDF (257K).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.
  • Spalton D, Koch D. The constant evolution of cataract surgery. BMJ. 2000 Nov 25;321(7272):1304–1304. [PMC free article] [PubMed]
  • Brandser R, Haaskjold E, Drolsum L. Accuracy of IOL calculation in cataract surgery. Acta Ophthalmol Scand. 1997 Apr;75(2):162–165. [PubMed]
  • Olsen T, Bargum R. Outcome monitoring in cataract surgery. Acta Ophthalmol Scand. 1995 Oct;73(5):433–437. [PubMed]
  • Wegener M, Alsbirk PH, Højgaard-Olsen K. Outcome of 1000 consecutive clinic- and hospital-based cataract surgeries in a Danish county. J Cataract Refract Surg. 1998 Aug;24(8):1152–1160. [PubMed]
  • Murphy Christopher, Tuft Stephen J, Minassian Darwin C. Refractive error and visual outcome after cataract extraction. J Cataract Refract Surg. 2002 Jan;28(1):62–66. [PubMed]
  • Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992 Mar;18(2):125–129. [PubMed]
  • Pierro L, Modorati G, Brancato R. Clinical variability in keratometry, ultrasound biometry measurements, and emmetropic intraocular lens power calculation. J Cataract Refract Surg. 1991 Jan;17(1):91–94. [PubMed]
  • Mendívil A. Intraocular lens implantation through 3.2 versus 4.0 mm incisions. J Cataract Refract Surg. 1996 Dec;22(10):1461–1464. [PubMed]
  • Elder MJ. Predicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T. Br J Ophthalmol. 2002 Jun;86(6):620–622. [PMC free article] [PubMed]
  • Connors Rafe, 3rd, Boseman Peter, 3rd, Olson Randall J. Accuracy and reproducibility of biometry using partial coherence interferometry. J Cataract Refract Surg. 2002 Feb;28(2):235–238. [PubMed]
  • Lundström M, Barry P, Leite E, Seward H, Stenevi U. 1998 European Cataract Outcome Study: report from the European Cataract Outcome Study Group. J Cataract Refract Surg. 2001 Aug;27(8):1176–1184. [PubMed]
  • Steinert RF, Aker BL, Trentacost DJ, Smith PJ, Tarantino N. A prospective comparative study of the AMO ARRAY zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens. Ophthalmology. 1999 Jul;106(7):1243–1255. [PubMed]
  • Mamalis Nick. Complications of foldable intraocular lenses requiring explantation or secondary intervention--2001 survey update. J Cataract Refract Surg. 2002 Dec;28(12):2193–2201. [PubMed]
  • Hoffer KJ. Biometry of 7,500 cataractous eyes. Am J Ophthalmol. 1980 Sep;90(3):360–368. [PubMed]
  • Sun XY, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology. 2000 Sep;107(9):1776–1782. [PubMed]
  • Till Jonathan Stanwood, Yoder Paul R, Jr, Wilcox Thomas K, Spielman Jeffrey L. Toric intraocular lens implantation: 100 consecutive cases. J Cataract Refract Surg. 2002 Feb;28(2):295–301. [PubMed]
  • Javitt JC, Steinert RF. Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes. Ophthalmology. 2000 Nov;107(11):2040–2048. [PubMed]
  • Javitt JC, Wang F, Trentacost DJ, Rowe M, Tarantino N. Outcomes of cataract extraction with multifocal intraocular lens implantation: functional status and quality of life. Ophthalmology. 1997 Apr;104(4):589–599. [PubMed]
  • Jacobi Philipp C, Dietlein Thomas S, Lüke Christoph, Jacobi Felix K. Multifocal intraocular lens implantation in prepresbyopic patients with unilateral cataract. Ophthalmology. 2002 Apr;109(4):680–686. [PubMed]
  • Hoffman Richard S, Fine I Howard, Packer Mark. Refractive lens exchange with a multifocal intraocular lens. Curr Opin Ophthalmol. 2003 Feb;14(1):24–30. [PubMed]
  • Packer Mark, Fine I Howard, Hoffman Richard S. Refractive lens exchange with the array multifocal intraocular lens. J Cataract Refract Surg. 2002 Mar;28(3):421–424. [PubMed]
  • Dick H Burkhard, Gross Susanne, Tehrani Mana, Eisenmann Dieter, Pfeiffer Norbert. Refractive lens exchange with an array multifocal intraocular lens. J Refract Surg. 2002 Sep-Oct;18(5):509–518. [PubMed]
  • O'Brien Terrence P, Awwad Shady T. Phakic intraocular lenses and refractory lensectomy for myopia. Curr Opin Ophthalmol. 2002 Aug;13(4):264–270. [PubMed]
  • Uusitalo Risto J, Aine Esko, Sen Nida H, Laatikainen Leila. Implantable contact lens for high myopia. J Cataract Refract Surg. 2002 Jan;28(1):29–36. [PubMed]
  • Davidorf JM, Zaldivar R, Oscherow S. Posterior chamber phakic intraocular lens for hyperopia of +4 to +11 diopters. J Refract Surg. 1998 May-Jun;14(3):306–311. [PubMed]
  • Landesz M, Worst JG, van Rij G. Long-term results of correction of high myopia with an iris claw phakic intraocular lens. J Refract Surg. 2000 May-Jun;16(3):310–316. [PubMed]
  • Seitz B, Langenbucher A. Intraocular lens power calculation in eyes after corneal refractive surgery. J Refract Surg. 2000 May-Jun;16(3):349–361. [PubMed]
  • Seitz B, Langenbucher A. Intraocular lens calculations status after corneal refractive surgery. Curr Opin Ophthalmol. 2000 Feb;11(1):35–46. [PubMed]
  • Gimbel HV, Sun R, Furlong MT, van Westenbrugge JA, Kassab J. Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy. J Cataract Refract Surg. 2000 Aug;26(8):1147–1151. [PubMed]
  • Odenthal Monica T P, Eggink Cathrien A, Melles Gerrit, Pameyer Jan H, Geerards Annette J M, Beekhuis W Houdijn. Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia. Arch Ophthalmol. 2002 Apr;120(4):431–438. [PubMed]
  • Schwartz DM, Jethmalani JM, Sandstedt CA, Kornfield JA, Grubbs RH. Post implantation adjustable intraocular lenses. Ophthalmol Clin North Am. 2001 Jun;14(2):339–viii. [PubMed]
  • Nishi O, Nishi K, Sakanishi K. Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic Surg Lasers. 1998 Jul;29(7):587–594. [PubMed]
  • Vargas Luis G, Peng Qun, Apple David J, Escobar-Gomez Marcela, Pandey Suresh K, Arthur Stella N, Hoddinott Daphne S M, Schmidbauer Josef M. Evaluation of 3 modern single-piece foldable intraocular lenses: clinicopathological study of posterior capsule opacification in a rabbit model. J Cataract Refract Surg. 2002 Jul;28(7):1241–1250. [PubMed]
  • Izak Andrea M, Werner Liliana, Apple David J, Macky Tamer A, Trivedi Rupal H, Pandey Suresh K. Loop memory of haptic materials in posterior chamber intraocular lenses. J Cataract Refract Surg. 2002 Jul;28(7):1229–1235. [PubMed]
  • Zuclich JA, Connolly JS. Ocular damage induced by near-ultraviolet laser radiation. Invest Ophthalmol Vis Sci. 1976 Sep;15(9):760–764. [PubMed]
  • Ham WT, Jr, Mueller HA, Ruffolo JJ, Jr, Guerry D, 3rd, Guerry RK. Action spectrum for retinal injury from near-ultraviolet radiation in the aphakic monkey. Am J Ophthalmol. 1982 Mar;93(3):299–306. [PubMed]
  • Koch DD, Samuelson SW, Haft EA, Merin LM. Pupillary size and responsiveness. Implications for selection of a bifocal intraocular lens. Ophthalmology. 1991 Jul;98(7):1030–1035. [PubMed]
  • Hayashi K, Hayashi H, Nakao F, Hayashi F. Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lens. Ophthalmology. 2001 Nov;108(11):2011–2017. [PubMed]
  • Crouch Eric R, Crouch Earl R, Jr, Pressman Scott H. Prospective analysis of pediatric pseudophakia: myopic shift and postoperative outcomes. J AAPOS. 2002 Oct;6(5):277–282. [PubMed]
  • Plager David A, Kipfer Hal, Sprunger Derek T, Sondhi Naval, Neely Daniel E. Refractive change in pediatric pseudophakia: 6-year follow-up. J Cataract Refract Surg. 2002 May;28(5):810–815. [PubMed]
  • McClatchey SK, Dahan E, Maselli E, Gimbel HV, Wilson ME, Lambert SR, Buckley EG, Freedman SF, Plager DA, Parks MM. A comparison of the rate of refractive growth in pediatric aphakic and pseudophakic eyes. Ophthalmology. 2000 Jan;107(1):118–122. [PubMed]
  • Roberts C. The cornea is not a piece of plastic. J Refract Surg. 2000 Jul-Aug;16(4):407–413. [PubMed]
  • Schwiegerling Jim, Snyder Robert W, Lee James H. Wavefront and topography: keratome-induced corneal changes demonstrate that both are needed for custom ablation. J Refract Surg. 2002 Sep-Oct;18(5):S584–S588. [PubMed]
  • Werner L, Pandey SK, Apple DJ, Escobar-Gomez M, McLendon L, Macky TA. Anterior capsule opacification: correlation of pathologic findings with clinical sequelae. Ophthalmology. 2001 Sep;108(9):1675–1681. [PubMed]
  • Cochener B, Jacq PL, Colin J. Capsule contraction after continuous curvilinear capsulorhexis: poly(methyl methacrylate) versus silicone intraocular lenses. J Cataract Refract Surg. 1999 Oct;25(10):1362–1369. [PubMed]
  • Hayashi K, Hayashi H, Nakao F, Hayashi F. Reduction in the area of the anterior capsule opening after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. Am J Ophthalmol. 1997 Apr;123(4):441–447. [PubMed]
  • Macky TA, Pandey SK, Werner L, Trivedi RH, Izak AM, Apple DJ. Anterior capsule opacification. Int Ophthalmol Clin. 2001 Summer;41(3):17–31. [PubMed]
  • MacCumber Mathew W, Packo Kirk H, Civantos Joseph M, Greenberg Jason B. Preservation of anterior capsule during vitrectomy and lensectomy for retinal detachment with proliferative vitreoretinopathy. Ophthalmology. 2002 Feb;109(2):329–333. [PubMed]
  • Auffarth GU, Schmidbauer J, Becker KA, Rabsilber TM, Apple DJ. Miyake-Apple-Video-Analyse des Bewegungsmusters einer akkommodativen Intraokularlinse. Ophthalmologe. 2002 Nov;99(11):811–814. [PubMed]
  • Küchle M, Nguyen NX, Langenbucher A, Gusek-Schneider GC, Seitz B. Zwei Jahre Erfahrung mit der akkommodativen Hinterkammerlinse 1 CU. Ophthalmologe. 2002 Nov;99(11):820–824. [PubMed]

Articles from Transactions of the American Ophthalmological Society are provided here courtesy of American Ophthalmological Society