Br Heart J. 1989 February; 61(2): 167–171.
PMCID: PMC1216635

Determination of the ratio of pulmonary blood flow to systemic blood flow by derivation of amplitude weighted mean velocity from continuous wave Doppler spectra.

Abstract

Conventional Doppler echocardiographic techniques for the estimation of blood flow ratios depend on the precise measurement of the diameters of the aorta and the pulmonary artery and the mean blood flow velocities in these vessels. A simpler and quicker method is described, based on the calculation of the systolic time integrals of the amplitude weighted mean velocities from continuous wave Doppler spectra within the great arteries. In 30 controls the mean (2 SD) ratio of pulmonary to systemic blood flow averaged 0.952 (0.085). The results of the new technique showed a good agreement with those of quantitative dye dilution and oximetry in 16 patients with intracardiac left to right shunts.

Full text

Full text is available as a scanned copy of the original print version. Get a printable copy (PDF file) of the complete article (847K), or click on a page image below to browse page by page. Links to PubMed are also available for Selected References.

Images in this article

Click on the image to see a larger version.

Selected References

These references are in PubMed. This may not be the complete list of references from this article.
  • Hottinger CF, Meindl JD. Blood flow measurement using the attenuation-compensated volume flowmeter. Ultrason Imaging. 1979 Jan;1(1):1–15. [PubMed]
  • FRITTS HW, Jr, HARRIS P, CHIDSEY CA, 3rd, CLAUSS RH, COURNAND A. Validation of a method for measuring the output of the right ventricle in man by inscription of dye-dilution curves from the pulmonary artery. J Appl Physiol. 1957 Nov;11(3):362–364. [PubMed]
  • Gardner MJ, Altman DG. Confidence intervals rather than P values: estimation rather than hypothesis testing. Br Med J (Clin Res Ed) 1986 Mar 15;292(6522):746–750. [PMC free article] [PubMed]
  • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed]
  • Shung KK, Yuan YW, Fei DY, Tarbell JM. Effect of flow disturbance on ultrasonic backscatter from blood. J Acoust Soc Am. 1984 Apr;75(4):1265–1272. [PubMed]
  • Angelsen BA. A theoretical study of the scattering of ultrasound from blood. IEEE Trans Biomed Eng. 1980 Feb;27(2):61–67. [PubMed]

Articles from British Heart Journal are provided here courtesy of BMJ Group